Ascotel® IntelliGate® 150/300 as of I7.9
Operation and Maintenance
203
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
Note:
Event tables and signal destinations should be set in such a way that the
event message
Internal event message destination missing
" is signalled
immediately to any signal destination still available.
Configuring a local signal destination on a V.24 interface
The local signal destination is connected to the V.24 interface of a Pocket Adapter
(PA).
The "
Local Output Interface
" must be set on "
Printer
" in the Fault & Maintenance
Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
•
Location of the V.24 interface to which the local output destination is connected
(V.24 PA = Pocket Adapter)
•
Required output format "
PC
" or "
Printer
" (see
•
With "
Printer
" output format: Language in which the event messages are to be
output.
•
With the V.24 interface on the PA - port address
•
With "
PC
" and “
Printer
” output format as the output location: Maximum page
length of the printout
Output formats
There are two output formats available for local signal destinations connected to a
V.24 interface.
•
Printer Format
•
PC format
Printer Format
Fig. 81
Event signal format "
Printer
" for printer as the local output destination (example with date,
time and event message)
11.03.97 10:12 LOSS OF SYNC ON T/T2 O.9
haz1234aaena0
11.03.97 10:12 LOSS OF SYNC ON T/T2 O.9
haz1234aaena0