FUNCTION CODE

DESCRIPTION

“Master Code”

This is a 4 digit programmable code between 0000 

and 9999 used for gaining access to the program 

mode. The factory default is “ 1 2 5 1”.

“Relay A Latch Card”

This is a user programmable card(s)  used to lock 

down (or unlock) relay A.  This code will be used to 

hold open a gate or door connected to relay A.

“Relay B Latch Card”

This is a user programmable card(s)  used to lock 

down (or unlock) relay B.  This code will be used to 

hold open a gate or door connected to relay B.

“Sleep Card”

This is a programmable card(s) that is used to toggle 

the unit in and out of the sleep mode. In the sleep 

mode all codes are disabled with the exception of 

the MANAGERS CARDS.  When the “SLEEP CARD”  is 

placed up to the reader again, the unit will wake 

up.

“APB Master Code”

This is a programmable code used to clear the 

antipassback status of cards in memory.  

“Second Relay Card”

This is a programmable card(s) used to momentarily 

activate relay B. 

“Managers Cards”

This is a programmable card(s) used to gain access 

onto the property. This card(s) will activate the 

appropriate relay regardless of the sleep state of 

the unit. 

FUNCTION CODES

GOODBEEPS, ERRORBEEPS, & QUICKBEEPS

Your unit will beep each time a key is pressed.  The “*” key serves as the clear key and a double beep will be heard 

when this key is pressed.  A “GOODBEEP” is represented by an oscillating high tone.  An “ERRORBEEP” is represented 

by a single low tone.  A “QUICKBEEP” is a series of 5 quick high beeps in succession.

THE RED & YELLOW LED’s

Two different colored LED’s are mounted in the face of the unit.  The RED LED will light during the duration of the 

relay(s) activation period.  The YELLOW LED will light while the unit is in the program mode.  During memory clear or 

setup both LED’s will flash.  The RED LED will also be lit when you enter a submode and the feature is already enabled.

RESETTING THE UNIT

Your PROX 2000 II unit provides two different types of resets, a UNIT RESET, and a MASTER RESET.  A MASTER RESET should 

be utilized in the event that you lose or forget your master code or if the unit is locked in the sleep, lockA, or lockB 

mode.  When a MASTER RESET is performed, only the master code will be changed.  A UNIT RESET is provided should 

it ever become necessary to reset the unit back to the initial factory state.  After a UNIT RESET has been performed 

the unit will erase all ACCESS & FUNCTION codes from memory and the master code will be set back to the factory 

default of  1 2 5 1.

Содержание 2000 23-206

Страница 1: ...PROX 2000 II MODEL 23 206 i User Installation Manual www americanaccess com Your PARTNER in Access Control...

Страница 2: ...ealer or installer of the product and return your AAS product along with the receipt to them If you have problems locating the dealer or installer contact American Access Systems at 303 7999757 and we...

Страница 3: ...s Qty Description 1 Post Mount Station 1 16 5 VAC 20VA Transformer If any of the above items are missing from this box contact American Access Systems Tools Needed For Basic Installation Wire stripper...

Страница 4: ...All PROXIMITY CARDS entered on PROX 1 will operate relay A and all cards entered on PROX 2 will operate relay B SPLIT RELAY FEATURE The relay output times are user selectable from 1 to 99 seconds and...

Страница 5: ...correctly apply power to the unit If this is the first time power up the unit will perform some self diagnostics and setup the memory The unit will flash the LED s several times while it is performin...

Страница 6: ...rded transactions The transactions may be printed as they occur or the contents of the history buffer may be dumped out to the printer Note A standard serial printer WILL NOT work with the 23 206 Conn...

Страница 7: ...sleep state of the unit FUNCTION CODES GOODBEEPS ERRORBEEPS QUICKBEEPS Your unit will beep each time a key is pressed The key serves as the clear key and a double beep will be heard when this key is p...

Страница 8: ...ill go through the FIRST TIME POWER UP sequence See HOOKUP STEPS page 5 step C THE IDLE MODE The idle mode is the normal mode of operation When in this mode the unit sits and waits for data from the k...

Страница 9: ...104 Program Relay B Latch Card s Block Format 105 Program Relay B Card s Block Format 106 Set System Facility Code 3 max 108 Change System Master Code 109 Change Quick Entry Master Code 110 Change Qu...

Страница 10: ...E 106 When memory is completely filled you will not be able to enter this SubMode and will receive an ERROR if entry is attempted QUICK ENTRY MODE DESCRIPTION Quick entry mode is another way to progra...

Страница 11: ...ubmode 104 then enter the STARTING CARD NUMBER and then the ENDING CARD NUMBER you wish to program into the unit MASTER CODE 104 STARTING CARD NUMBER ENDING CARD NUMBER EXAMPLE TO VALIDATE A SINGLE CA...

Страница 12: ...ry master code enter the 4 digit MASTER CODE followed by submode 109 then the NEW QUICK ENTRY MASTER CODE you wish to program into the unit MASTER CODE 109 NEW QUICK ENTRY MASTER CODE The unit will re...

Страница 13: ...may be desired To set the output time of relay A in seconds enter the 4 digit MASTER CODE followed by submode 300 and then a 2 digit number corresponding to the number of seconds MASTER CODE 300 SECON...

Страница 14: ...to keep end users from passing their cards back allowing other users to gain access onto the property The PROX 2000 II unit incorporates a true AntiPassBack feature in which an end user enters his ent...

Страница 15: ...shed it will respond with a GOODBEEP and exit from the program mode To halt printing simply turn the printer off 401 SubMode 401 PRINT OUT ALL CURRENT ACCESS CARDS NOTE THE UNIT MUST BE INTERFACED TO...

Страница 16: ...05 PRINT OUT CURRENT UNIT CONFIGURATION This is a very convenient way to see what is the PROX 2000 II current configuration This will print out the status of Split Relay APB Quiet Mode and red printin...

Страница 17: ...Page 17 American Access Systems Security Brands Inc Access Name...

Страница 18: ...curity Brands Inc CONNECTION FOR 12 VOLT BULB RESET BUTTON MASTER BOARD CONNECTOR FOR COMMUNICATIONS AND RELAYS BOARD PRINTER POWER TRANSFORMER PLUG IN COMMUNICATIONS AND RELAYS BOARD SEE PAGE 6 WIEGA...

Страница 19: ...our Technicians assist you E Mail customerservice securitybrandsinc com Technical Support 303 799 9757 Technical support is available free of charge Hours are 8 00 a m to 4 30 p m MST If you call plea...

Страница 20: ...Your partner in access control www securitybrandsinc com SECURITY BRANDS INC...

Отзывы: