(sizeφ2) into the wall. Hang the appliance on the nail with the hanging hole as the 

drawing below:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4 Connection drawing of gas detector with functions of gas shut off valve or relay output, 

see above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

5 Using Instructions:

 

 

5.1 GD201/ GD221/GD401/GD501/GD601/GD801

 

AARU

 

ENGINEERS                                          www.aaruengineers.com

 

 

5.1.1. Plug in, (If ventilate fan, electro valve or other equipment is need to be connected, 

please connect corresponding circuit firstly.), then the green POWER light and yellow W -

UP light  will be  on. The  appliance  assumes non-operating status for three  minutes  while 

the sensor  warms up. After  warm up, the  yellow W -UP light  will be  off  automatically  and 

the appliance enters detecting status.  

 
5.1.2. If the gas in the environment rises above the preset alarm level, the appliance will 

enter  alarm  status,  the  red  ALARM  light  will  shine  and  the  buzzer  will  give  sound 

alarming.  Meanwhile,  the  alarm  will  activate  the  relay  or  the  valve  output;  at  the  same 
time, please cut off gas supply promptly and open the window. Don’t try to switch on or off 

any  electric  appliance,  including  mobile  phone  and  such  communications  tools.  Ask 

professional  person  to  eliminate  the  gas  leaking  malfunction  quickly  (the  alarm  with 

function of gas shut off valve shall output one close pulse signal each 10 seconds)  

5.1.3.  Once  the  gas  concentration  around  drop  under  the  preset  alarming  level,  the 

detector  will  stop  alarming  automatically  and  the  ventilating  fan  will  also  stop 

automatically. The detector gets into detecting state again.  

 

5.1.4.  If  the  yellow  fault  alarm  light  is  on,  it  shows  there  is  something  wrong  with  the 
detector and the detector can’t detect gas. Then please contact the distributor.  

5.1.1  Button operation:  

 

W-UP: press this button to stop the warm up and the detector get into detecting state 

immediately.  

 

Test  button:  The  appliance  will  simulate  alarming  by  pressing  test  button  under 

detecting status.  

 

5.2 GD701 

 

 
5.2.1. Plug in, (If ventilate fan, electro valve or other equipment is need to be connected, 

please connect corresponding circuit firstly.), then the green POWER light and yellow W -

UP light  will be  on. The  appliance  assumes non-operating status for three  minutes  while 

the sensor  warms up. After  warm up, the  yellow W -UP light  will be  off  automatically  and 

the appliance enters detecting status.  

 
After the  power light shines for 60s, it  will flash for 90s. The  detector  will  detect the CO 

gas in the end of the 90s.  

 

5.1.3.  If  the  gas  in  the  environment  rises  above  the  preset  alarm  level,  the  red  ALARM 

light will flash, the buzzer give sound alarming, drive the relay or valve shut off gas supply, 

Meanwhile, the alarm will activate the relay or the valve output; At the  same time, please 

cut  off  gas  supply  promptly,  and  open  the  window,  ask  professional  person  to  eliminate 

the gas leaking malfunction quickly.

 

 

The detector will make detection each 150s.

 

 

Once the gas concentration around drop under the preset alarming level, the detector will 

stop  alarming  automatically  and  the  ventilating  fan  will  also  stop  automatically.  The 

detector gets into detecting state again.

 

 

5.2.3 Lights

 

 