OPERATING INSTRUCTIONS

CLEANING

Important; Under some circumstances soot can quickly
build up on the throat plate and adjacent areas. The
throat plate should be removed and checked monthly,
and any debris stripped off. Similarly, clean the upper
surface of the firebox.

ANNUAL MAINTENANCE

It is important that your fire is regularly serviced in
accordance with these instructions. This should be
carried out at least annually by a qualified person and
should consist of the following.

Remove the firebricks lining and throat plate, inspect all
gasketing on doors, glass etc., and re-order any items
that may need replacing, from your Aarrow dealer.
With a wire brush clean inside the appliance paying
attention to the small inlet holes on the fire door.  

Sweep the chimney and confirm that it is sound.
Examine all joints in the flue pipe etc., and re-seal if
necessary. Reassemble and leave with the air inlet and
air wash control about half way open. This will allow a
free flow of air through the appliance thus preventing
moisture and condensation from building up inside the
fire and chimney.

CHIMNEY SWEEPING

Sweeping should be carried out with an appropriate
sized bristle brush and rods to suit chimney size and
type. As with all appliances regular sweeping of the flue
is essential to avoid the danger of blockage and the
escape of  poisonous fumes. Access for cleaning should
also be incorporated in the chimney (e.g. soot door or
access through register plate).
Any existing chimney should be swept prior to
installation of the appliance, and swept again a  second
time 

within one month 

of regular use after installation

to establish frequency of sweeping required. 
This should be done by a competent person such as a
NACS chimney engineer who will provide a Certificate
of Chimney Sweeping.

The whole flue way including the outlet must be swept
at least twice per burning season. It is important that the
flue ways, flue pipe and chimney be cleaned prior to
lighting the fire after a prolonged shut-down period.

DOOR GLASS

The door glass should remain clear during normal
daytime burning. However under certain conditions-such
as burning at a low rate with damp wood, or overnight
burning, the glass may become somewhat blackened. To
remedy this, operate the appliance at a fast rate. 
Alternatively when the stove is cold open the door and
clean the inside face of the glass with a damp cloth or
with glass cleaner  (available from fire stockists). Apiece
of cloth moistened with vinegar and dipped in wood ash

not coal ash

- will provide a good soft scourer to

remove the soot without scratching the glass.

OUTER FINISH

The outside finish of the appliance is a durable high
temperature paint. It is best cleaned by brushing down
with a clean shoe brush. Do not allow moisture to remain
on the appliance whilst cold or surface rust may form.
The high temperature paint should not require attention
for some time, depending on use. The  hotter the fire
burns the sooner repainting will be necessary. Aerosol
tins of paint are available for complete refurbishing.
Before repainting make sure that the fire is out and is
cold.
•Remove the door glass.
•Lightly wire brush, or rub with wire wool, the body of   

the appliance to remove any loose paint  
powder.

•Mask or remove items such as brass work.
•Any adjacent brickwork, mantelpiece, hearth, etc.,
should be carefully masked for quite a distance around
the appliance. (this precaution is to prevent
discolouration of the surrounding brickwork,
wallpaper etc).

Re-spray in a well-ventilated area - avoid breathing
the vapour. Refer to safety instructions on paint
cans.

•When the paint is dry refit door glass and any other 

parts previously removed.

•Leave the appliance for eight hours before-lighting. 
•Burn slowly for the first four hours, then build up heat 

gradually to cure the paint.

Note: Use only genuine Aarrow touch-up spray as
some paints interact. This could ruin the finish and
invalidate the guarantee.
Note: Cracking of lining panels does not effect
efficiency.

Содержание Tf 70

Страница 1: ...t Britain Tel 44 01308 427234 Fax 44 01308 423441 www aarrowfires com Acorn Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE The Acorn 4 Multifuel S...

Страница 2: ...y we are so confident in the reliability of our product that we offer a 3 year guarantee Should you have any questions about our Acorn Stoves that are not covered in this manual please contact the Aar...

Страница 3: ...g the Multifuel Grate 10 Flues Chimneys 11 14 Add in Boilers 15 16 OPERATING INSTRUCTIONS Page AirInlet Controls 16 17 Airwash System 16 17 Multi Purpose Operating Tool 17 Fire Door Glass 17 18 Adjust...

Страница 4: ...BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPAR...

Страница 5: ...not properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Aarrow produce a variety of applian...

Страница 6: ...pan 1 7 Operating tool 1 8 Rear liners 1 9 Side liners 2 10 Fire door handle 1 11 Instructions 1 The model and Serial Number of your fire can be found stamped into the casing centrally just below the...

Страница 7: ...estic Hot Water with add in boiler type Type 7 Max Output to Room kW Max Output to Water kW 3 1 5 Height mm 458 Width mm 355 Depth mm 350 Height to Centre of Rear Flue 360 Depth from Back to Centre of...

Страница 8: ...should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project at least 30...

Страница 9: ...plate and grate in the Acorn REMOVAL OF THE THROAT PLATE Blocked chimneys cause dangerous fumes to escape Remove the throat plate at least monthly to clean Keep chimney and flue ways clear FITTING THE...

Страница 10: ...ring end marked L onto the low section of the comb The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seated on the high section of...

Страница 11: ...he flue size suits the stove The termination of the outlet at the top of the flue also needs to comply with the Building Regulations The minimum effective height of the flue must be at least 4 5 metre...

Страница 12: ...Notice Plate giving details on the chimney flue lining hearth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The Stationery Booksho...

Страница 13: ...Acorn Multifuel Stoves 13 INSTALLATION TYPICAL REAR FLUE OUTLET...

Страница 14: ...THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non insu...

Страница 15: ...n in an area with soft water If radiators are used then an indirect system must be utilised To connect the cylinder use 28mm copper pipes Ensure that the pipes rise continuously to the cylinder Ensure...

Страница 16: ...tains becoming burnt on Check the flue draught which should read 1 2mm or 0 1 0 2mbar The following details must be checked and completed in full by the installer at the time of installation Please an...

Страница 17: ...g the multifuel grate position and for emptying the ash pan Fig 10 Fig 10 RIDDLING Use the operating tool for setting the grate in the coal burning position or the wood burning position This means tha...

Страница 18: ...e case of hard wood We recommend that for general burning wood should be split into logs of no more than 130mm 5 diameter Larger logs can be used for overnight burning WARNING wet wood must not be use...

Страница 19: ...closed Set the air wash to one quarter open position Set the primary inlet to the fully open position Light in the normal manner with paper and kindling or use a fire lighter If using a gas poker be s...

Страница 20: ...e taken not to risk burning of hands or household objects from falling embers DE ASHING It is necessary to maintain an ash layer on the upper surface of the grate bars in order to protect them so de a...

Страница 21: ...It is important that the flue ways flue pipe and chimney be cleaned prior to lighting the fire after a prolonged shut down period DOOR GLASS The door glass should remain clear during normal daytimebu...

Страница 22: ...appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbished...

Страница 23: ...ainer AFS1101 AFS1086 AFS001 AFS064 AFS008 AFS1273 AFS009A 2 Throat Plate 3 Grate Bar 4 Hot Plate 5 Operating Tool 6 Ashpan 7 Flue Spigot Part Description Visual Aid not to scale Acorn 4 Part No AFS11...

Страница 24: ...047 AFS1097 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips 13 Hinge kit Comprises 2 Hinges 4 Fixings Per Set 14 Airwash Part Description Visual Aid not to...

Страница 25: ...te with Handle Glass Gaskets Clips and Seal 17 Comb with Extension 18 Fire Door Locking Assembly Including Fire Door Handle 20 Aarrow Fires Gauntlet Gloves Part Description Visual Aid not to scale Aco...

Страница 26: ...engineer The Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repair or replace it FREE OF CHARGE...

Страница 27: ...s manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart...

Страница 28: ...G INSTRUCTIONS Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on p...