background image

 

21

For Stratford Si 

 

Engage the operating tool on the comb extention. 

 

Move up and down vigorously the riddling lever (Ash will fall into the ash pan beneath the grate). 

 

When de-ashing is complete re-set grate to previous position. 

 

Empty ash pan 

 
The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the pan. On no 
account should the ash be allowed to build up to touch the grate as this will greatly shorten its life. 
 

To empty the ash pan 

Open the fire door; open the ash door. Fit the fork end of the operating tool into the ash pan and remove from the 
ash pit chamber. The ash pan on some large appliances has a pivoted "strap" handle to make carrying easier. This 
handle can get very hot and an oven glove or similar should be used. 
 

Warning: The ash can be very hot. Empty only to a metal container. Even if the ash appears cold, red-hot 

pieces of ash may be concealed and could easily start a fire or cause an injury. Replace the ash pan and 

close ash door. Close the fire down. 

 

Over-firing 

Do not over fire your appliance. Using flammable liquids or too much wood or firing the stove at maximum for 
prolonged periods may result in over-firing. If the chimney connector or casing glows red it is being over-fired. 
If this occurs immediately close all air inlets to the appliance to reduce the air supply to the fire. Should a 
chimney fire occur immediately close the appliance down. Get everyone out of the house and call the fire 
brigade. A chimney fire may cause a structural damage of the chimney. Do not use the appliance until the 
chimney and connector have been inspected and any damaged parts have been repaired or replaced. A chimney 
sweep can perform this inspection. 
 

Clinker 

The formation of clinker suggests that the unit is being over-fired. Any clinker forming on the grate should be 
removed when cold. 
 
 
 

15. CLEANING 

 
 

Important 

Under some circumstances soot can quickly build up on the throat plate and adjacent areas. The throat plate 
should be removed and checked monthly, and any soot stripped off. Similarly, clean the upper surface of the 
firebox. 

Refer to page 7 for instructions on throat plate inspection. 

It is important that your fire is regularly serviced in accordance with the manufacturers instructions at least 
annually by a qualified person and should consist of the following. 

 

Annual Maintenance 

Remove the firebricks lining (if fitted), throat plate, grate bars and ash pan. Also inspect all gasketing on doors 
glass etc., and re-order any items that may need replacing, 

from your Aarrow dealer

. With a wire brush clean 

inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above the 
fire door and to the door interlock ensuring free movement of the mechanism exists. Sweep the chimney and 
confirm that it is sound. Examine all joints in the flue pipe etc., and re-seal if necessary. Reassemble and leave 
with the air inlet and air wash control about half way open. This will allow a free flow of air through the 
appliance thus preventing moisture and condensation from building up inside the fire and chimney. 
 

Chimney Sweeping 

Sweeping should be carried out with a wire-centred sweep's brush fitted with a guide wheel. As with all 
multifuel appliances regular sweeping of the flue is essential to avoid the danger of blockage and the escape of 
poisonous fumes. 
Any existing chimney should be swept prior to installation of the appliance, and swept again a second time 

within one month

 of regular use after installation. Sweep the whole flue way, including the outlet, at least twice 

per burning season. It is important that the flue ways, flue pipe and chimney be cleaned prior to lighting the fire 
after a prolonged shut-down period. 

Stop using the appliance if you smell fumes or see smoke escaping. 

Содержание Stratford Sf 50 Convector

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS The Stratford Multifuel Sf Si Stoves Stratford Sf 50 Convector PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...we are so confident in the reliability of our product Should you have any questions about our Stratford Stoves that are not covered in this manual please contact the Aarrow dealer in your area or cal...

Страница 3: ...ments 13 9 Spare Parts List 14 A Stratford Sf B Stratford Si 10 Accessories 16 11 Fuels 17 12 Lighting the Fire 18 13 Overnight burning 19 14 Ash removal 20 15 Cleaning 21 16 Safety 22 Installation In...

Страница 4: ...OR WONDERCO MUST NOT BE BURNED IN THIS APPLIANCE TO USE THIS FUEL WILL INVALIDATE THE APPLIANCE WARRANTY IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE FREEPHONE 0800 600000 THE USE OF SPAR...

Страница 5: ...condary combustion and directs the flue gas around the whole upper firebox before allowing it to escape to the chimney The primary air for burning enters the ash pit chamber beneath the grate controll...

Страница 6: ...1 1 1 1 1 1 1 1 1 1 1 1 Operating Tool 1 1 1 1 1 1 1 1 1 1 1 1 Thermostat 1 1 1 1 1 1 1 1 Instructions 1 1 1 1 1 1 1 1 1 1 1 1 Only the knob the thermostat is already fitted to the stove The model an...

Страница 7: ...ate bars Periodic inspection of the bars is recommended and the removal of any nails or wire that may be present after burning wood All the grate bars in each appliance are identical and can easily be...

Страница 8: ...0 Sf50 see Fig 3 4 Figure 3 Figure 4 Remove front fuel retainer bars Set the two linings on the side ledges on either side of the firebox Set the rectangular linings on the upper surface of the grate...

Страница 9: ...uel retainer bars Note Neither the rear linings nor the side linings are handed and both faces are suitable for direct contact with the fire 5 THROAT PLATE INSPECTION The throat plate for all fires ty...

Страница 10: ...regulates the amount of under draught entering depending on the setting of the thermostat control knob located at the bottom rear of the right hand side of the unit and the temperature of the water t...

Страница 11: ...the ash door has been shut first When the fire door is shut the ash door knob can be turned anti clockwise by up to 95 degrees creating a variable gap between the top of the ash door and the body thr...

Страница 12: ...two glass retainer clips on one side only inwards towards the centre of the door as far as they will go Pull this side of the glass away from the door casting easing the tags on the glass retaining cl...

Страница 13: ...the fire door so that it is at a right angle to the front face of the fire Lift the fire door up off the hinges Gently tap the two hinge pins in a direction to compensate for the misalignment Refit t...

Страница 14: ...4 AFS165 AFS166 AFS167 Grate Bar 11 AFS001 AFS001 AFS002 AFS003 Fire Bed Surround 12 AFS007 AFS007 AFS007 AFS007 Grate Bar landing with fixings Convector Models Boiler Models 13 AFS074 AFS075 AFS076 A...

Страница 15: ...AFS203 Ash pan 9 AFS054 AFS055 Comb Comb Extension 10 AFS062 AFS065 Grate Bar 11 AFS003 AFS003 Fire Bed Surround 12 AFS007 AFS007 Grate Bar landing with fixings Convector Models Boiler Models 13 AFS0...

Страница 16: ...rear firebox liner panel Stratford Sf convector units can be fitted with slab type boilers only not cantilever type Fitting Remove the fuel retainers rear firebox liner panels and throat plate Knock...

Страница 17: ...eter mm 127 5 127 5 127 5 127 5 152 6 152 6 152 6 152 6 TECHNICAL DATA THE STRATFORD Si RANGE Si 40 Convector Si 40 Boiler Si 60 Convector Si 60 Boiler Room Heater only Min Max output kW 2 10 N A 4 15...

Страница 18: ...and creosote which may in extreme cases run down the chimney in liquid form This will seriously damage both the chimney and appliance Note If you have sticky tar inside the appliance or chimney your...

Страница 19: ...e fire if it is suspected that any part of the water system is frozen Note The high temperature paint acquires durability by being cured during the initial firings of the appliance During this process...

Страница 20: ...deposits in the chimney This effect can be minimised by burning hard for a short period about 20 minutes twice a day It is usually convenient to do this morning and night Note To avoid chimney problem...

Страница 21: ...orming on the grate should be removed when cold 15 CLEANING Important Under some circumstances soot can quickly build up on the throat plate and adjacent areas The throat plate should be removed and c...

Страница 22: ...painting make sure that the fire is out and is cold Remove the door glass and gilt trim Lightly wire brush or rub with wire wool the body of the appliance to remove any loose paint powder Mask or remo...

Страница 23: ...are not damaged during installation 19 HEARTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulati...

Страница 24: ...y breast so that flow and return pipes can be connected to the appliance 23 CHIMNEY Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Fl...

Страница 25: ...maximum there should be a gap of 23mm between the fire and the edge of the damper plate furthest from the control shaft If this is not the case adjust by slackening off the lock nut and turning the a...

Страница 26: ...ng off the lock nut Replace the casing on the unit front and refit the control knob on to the thermostat shaft Positioning Appliance in recess Apply a thin cement slurry to the back of the hearth so t...

Страница 27: ...reviously removed and check unit thoroughly 25 FLUES AND CHIMNEYS Flexible stainless steel liners used on all oil and gas appliances are NOT suitable for solid fuel and MUST NOT BE USED The diameter o...

Страница 28: ...Soot door Horizontal 150mm 6 between support brackets 2 4 metres 8 0 maximum or Maximum 50mm 2 gap to wall 600mm 24 minimum TYPICAL PREFABRICATED Rain cap Non combustible ALL INSTALLATIONS MUST CONFOR...

Страница 29: ...ATER DRAW OFF DRAIN COCK RADIATORS RADIATORS CENTRAL HEATING RETURN 22mm PIPE GRAVITY RADIATOR 22mm OPEN VENTS GRAVITY FLOW 28mm PIPE PIPE STAT GRAVITY RETURN 28mm PIPE DRAIN COCK AT LOWEST POINT CIRC...

Страница 30: ...effective circulation can occur around the primary circuit to carry heat away and thus stop boiling The output of any radiator installed as a heat leak should not be less than 10 of the rated output...

Страница 31: ...FAIR BAD 4 What is the draught reading 14 What is the calculated output required to heat the system 5 Is the throat plate fitted YES NO 15 Is a heat leak fitted YES NO 6 What is the height of the flue...

Страница 32: ...price of replacement shall be shared by the manufacturer and purchaser as follows During the first year of purchase the manufacturer will pay 100 of the cost of parts only During the second year the...

Страница 33: ...p or Signature Should you have any questions about your fire that are not covered in this manual please contact our Technical Department on 01308 427234 Please keep all repair receipts safely Please e...

Страница 34: ...34 Manufactured by July 2001...

Отзывы: