USING THE HEATER
Switching on your heater
•
Ensure before connecting to the mains, that
all the switches are in the
OFF
position.
Located on the right hand side of the heater you
will find the switches to operate the fire.
ON
1kW
2kW
(A)
(B)
(C)
The first switch ‘A (as indicated in the diagram
above), switches on the fire and operates the
flame effect. If you only require the flame
effect with no heat, ensure switch ‘B’ is in the
top position and switch ‘C’ is in the top
position.
For 1kW setting
•
Switch (B) down to 1kW, leave ‘C’ set to top
position.
For 2kW setting
•
Leave ‘B’ set at 1kW and switch ‘C’ to 2kW.
Note: Switches ‘B’ and ‘C’ will not operate
without switch ‘A’ being on.
MAINTENANCE
WARNING - BEFORE UNDERTAKING
ANY MAINTENANCE OR CLEANING,
DISCONNECT FROM THE POWER
SUPPLY.
BULB REPLACEMENT
Bulbs have a limited lifespan and will require
replacing as they expire.
• Fully open the fire doors.
• Carefully lift out the coal ember bed, to reveal the
light fittings.
• Remove the faulty light bulb by unscrewing it.
• Replace with a
15W SES Pygmy Lamp.
• Replace the coal ember bed taking care not to
damage it.
CARE
Do not use water, detergents, abrasive cleaning
powder or polish of any kind on the body of the
heater.
Lightly brush with a medium dry brush.
TROUBLESHOOTING
No Heat or Light
• Check heater is plugged in and switched on at the
mains.
• Check the switches are correctly set.
• Check the 13A fuse in the plug. Replace if
necessary.
Heat but no Light in Coal Bed
• Replace light bulb - see instructions overleaf.
Light but no Heat
• The thermostatic cut-out has operated. This will
re-set after a short period of time.
• Ensure the air supply and venting are not
restricted.
• If still blowing cold air, unplug the heater and
phone our helpline.
No Flame-effect
• Unplug the heater and phone our helpline.
Bulbs do not last very long
• If the bulbs keep blowing there is not a fault with
the fire. It is not possible to predict the life of a
lamp, some burn out more quickly than others.
Noise from the fans
• Unfortunately there is always some noise from the
fans, we have done our utmost to reduce this but
they will never be completely silent.
4
Hamlet Electric Stove
OPERATING