background image

Aarrow Stove User Guide

3. Any claim under this guarantee must be made through the approved

Arada dealer where the stove was purchased and accompanied by proof

of purchase (e.g. a valid receipt). Stoves not purchased from an approved

Arada dealer will not be covered by this guarantee.

4. Your stove must be installed in the UK for this guarantee to be valid. Stoves

installed outside of the UK will not be covered by this guarantee.

5. Your stove must have been installed by a suitably qualified person and in

accordance with the manufacturer’s installation instructions. Stoves not

installed by a suitably qualified person or not installed in accordance with the

manufacturer’s installation instructions will not be covered by this guarantee.

6. Any claims under this guarantee shall not be valid where the installation of

the stove does not conform to all required building regulations and other

legislation in force at the time of purchase and where flue draw readings

have not been made to confirm a suitability of the flue. The manufacturer’s

decision as to whether this condition has been satisfied shall be final.

7. The guarantee does not cover damage caused to the stove through careless

handling or misuse or neglect of the appliance (misuse and neglect being

not following the manufacturer’s instructions and user guides in relation to

the stoves, including the use of non-recommended fuels).

8. The following consumable service items are not covered by this guarantee:

• Firebox linings
• Grate bars
• Fuel retainer
• Throat plate / FED plate / Baffle plate
• Gaskets
• Door glass
• Seals
• Associate parts

9. The guarantee does not cover damage caused by storing or using the

stove in a damp environment, defects or faults caused by local conditions

such as draught problems and chimney defects or corrosion caused

by condensation, damp or water ingress into the flue, chimney or the

surrounding of the stove.

10. The guarantee is only valid if the stove is serviced and checked annually by

a suitably qualified heating engineer, with documentation to be retained and

produced in the event of a claim being made.

11. The guarantee is only valid where any spare parts used are supplied

by Arada or an approved Arada dealer. The use of spares other than

those supplied by Arada Limited shall invalidate the guarantee. Parts can

BK530 Rev13

22

Содержание BK530

Страница 1: ...Aarrow Stove User Guide Aarrow Stove User Guide December 2015 BS EN 13240 2001 A2 2004 CE BK530 Rev13...

Страница 2: ...ld provide a lifetime of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical supp...

Страница 3: ...our stove 8 5 1 Smoke Control Zones 8 5 1 1 Refuelling on to a low fire bed 8 5 1 2 Fuel overloading 9 5 1 3 Operation with door left open 9 5 1 4 Dampers left open 9 5 2 Burning wood 9 5 3 Burning so...

Страница 4: ...ted heat 17 9 Ongoing care for your Aarrow stove 18 9 1 Adjusting the door hinges 18 9 2 Liners firebricks 18 9 3 Throat plate 19 9 4 Fire door seal 19 9 5 Cracked glass 19 10 Further resources readin...

Страница 5: ...ernment approved competent persons scheme such as operated by HETAS If in doubt contact HETAS Limited telephone 01684 278170 or visit www hetas co uk A fireguard conforming to BS 8423 2002 should be u...

Страница 6: ...ained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and...

Страница 7: ...e both the chimney and the appliance and increase the risk of a chimney fire 2 2 Solid fuel If you have chosen a multi solid fuel stove this will have a cast iron riddling grate which allows you to bu...

Страница 8: ...ned to help you get the best from your Aarrow stove Always wear suitable protective fire gloves when refuelling your stove such as the Arada glove supplied with your stove We recommend that you light...

Страница 9: ...ase of the fire chamber and the airwash system secondary air provides overdraught and airwash jets The exact controls may differ from those illustrated in this manual but will work in the same way Fig...

Страница 10: ...e air wash control for ECB5PLUS SC and ECB7PLUS SC cannot be fully closed This is to prevent shut down of the appliance 4 2 i Series air controls 4 2 1 i Series Cassette Stoves The Aarrow i Series cas...

Страница 11: ...Aarrow Stove User Guide Figure 2 i Series air inlet controls BK530 Rev13 7...

Страница 12: ...e check the data plate before operating in a Smoke Control Zone to ensure it is a compliant product indicated by the letters SCE or just SC following the product name The i400 400 T F SCE i500 SCE i60...

Страница 13: ...y of air coming from above the fuel For this reason we will use all the air inlets while igniting the stove but will then reduce this to air coming from the airwash system and over draught As much as...

Страница 14: ...se the primary air control on non i Series stoves as generally no air from below the grate is required when burning wood 5 3 Burning solid fuels If you have an i Series stove please read section 5 4 o...

Страница 15: ...e airwash should be opened sufficiently to keep the door glass clean Whilst burning solid fuel it can be beneficial to occasionally riddle the grate bars so any burnt fuel will fall between the grate...

Страница 16: ...y sliding it to the right see instructions on page 6 3 Light as with wood see steps 2 3 and 4 on page 9 with kindling and fire lighters 4 Once flue draw has been established after about five minutes c...

Страница 17: ...from your HETAS registered installer Do not attempt to re light the fire until the cause of the fume emission has been identified and corrected 5 5 1 Refuelling on to a low fire bed If there is insuf...

Страница 18: ...e Firing the stove at maximum for prolonged periods may result in over firing If the chimney connector or casing glows red the appliance is being over fired and this may result in a chimney fire 6 3 P...

Страница 19: ...The ash pan should be emptied when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up to touch the underside of the grate bars as this will greatly re...

Страница 20: ...ends marked L sitting on the low sections The riddling lever either on the side or front of your stove can be operated with the stove operating tool to riddle ash into the ash pan below Only riddle th...

Страница 21: ...heat the objects they strike It is then these objects such as the chimney breast hearth etc which heat the surrounding air 8 2 Convected heat Air immediately adjacent to the stove is heated as a resu...

Страница 22: ...erture or catch This is quite normal and due to the settling of the casting Doors attached with two hinges fixed to the body with screws can be re aligned as follows When the appliance is cold open th...

Страница 23: ...r ability to control the burn rate and its efficiency whilst leading to an increase in heat lost through the flue 9 5 Cracked glass It is not recommended to operate the stove with cracked glass this c...

Страница 24: ...ted articles HETAS www hetas co uk Solid Fuel Association www solidfuel co uk Document J Building Regulations Combustion Appliances www planningportal gov uk The National Association of Chimney Sweeps...

Страница 25: ...Arada stoves Non boiler Aarrow and Villager stoves come with a lifetime guarantee Non boiler Hamlet stoves come with a ten year guarantee Stratford and Villager boiler stoves come with a five year gua...

Страница 26: ...hether this condition has been satisfied shall be final 7 The guarantee does not cover damage caused to the stove through careless handling or misuse or neglect of the appliance misuse and neglect bei...

Страница 27: ...rable and solely for the benefit of the original purchaser of the stove 11 3 General Our guarantee is offered as an addition to your statutory rights and will not affect your statutory rights You can...

Страница 28: ...Aarrow Stove User Guide This page is left intentionally blank BK530 Rev13 24...

Страница 29: ...Aarrow Stove User Guide Manual last updated December 2015 Arada Ltd 2015 T 44 0 1297 35700 info aradastoves com Arada Ltd Weycroft Avenue Axminster Devon EX13 5HU www aradastoves com BK530 Rev13...

Отзывы: