Aaronia SPECTRAN V6 Скачать руководство пользователя страница 5

RTSA interface overview

The RTSA-Suite PRO is a very complex software. Please refer to the full manual for a detailed usage guide. This 

quick start guide only references a few parts of the interface that are briefly described below: 

 

Accessing the SPECTRAN® V6 settings

The mission which is loaded by default in the RTSA-Suite PRO uses all available screen space for displaying data. 

To access the settings of the SPECTRAN

®

 V6 it is necessary to open the Spectran V6 block by clicking on the 

“Spectran V6” tab above the Waterfall display in the lower part of the RTSA-Suite PRO application window. That 

action will switch the lower window section from the Histogram block to the Spectran V6 block where the device 

parameters can be adjusted:

SPECTRAN V6 Ribbon Bar

Access to Blockgraph Editor

Access to SPECTRAN V6 and

IQ Power Spectrum blocks

CPU Saturation

Performance Monitor

The image only shows some of the available settings, it could be necessary to 

scroll down and possibly open the available submenus (by clicking on the arrow 

on the left side of the setting) to see them all.

In the same way the FFT parameters in the “IQ Power Spectrum” block can be 

accessed, or the processing or display parameters of any other block.

Configuring the SPECTRAN® V6 RSA

The “Spectran V6” block provides many configuration options for tuning the device to your specific measurement 

scenario. This quick start guide describes the most important settings briefly. If a setting is not mentioned below it 

is recommended to leave it at its default value. 

G

roup „Main“:

Device Select

device is connected the “Any available” setting is recommended.

Center Frequency

Adjust this to match the frequency range to be measured.

Span

Adjusts the span of the frequency range to be measured, based on the selected RTBW. “Full” yields the maxi-

mum frequency range, the other settings will reduce it by the selected factor.

Full Spectrum

Makes the full RTBW spectrum available for use. By default, the outer areas are discarded to avoid possible artifacts.

Reference Level

This variable controls the sensitivity of the device. Strong signals may require tuning this up to increase the 

Connect / Disconnect

establish the connection automatically, but in some cases, it might be necessary to perform this connection manually.

Start / Stop

Start / stop the actual measurement. The default mission should automatically start it.

Содержание SPECTRAN V6

Страница 1: ...Check package contents Before your new SPECTRAN V6 can be used please verify that all necessary components are available and all requirements are met USB Stick with manual application software and ot...

Страница 2: ...USB connection when operating at full capacity In such scenarios connect the black cable labeled Boost to the BOOST port of the device and a second USB 3 x port on your PC Do not use a USB hub for con...

Страница 3: ...ment providing signal strengths of up to 20 dBm not suppor ted on RSA 250X RX TX REF One SMB input labeled REF to connect an external 10 MHz clock signal One SMB in output labeled TRG for synchronizin...

Страница 4: ...ar within a few seconds Attention Linux users The RTSA also works on Linux but the installer is not included on the USB stick and needs to be downloaded from our website For obvious reasons the instal...

Страница 5: ...all In the same way the FFT parameters in the IQ Power Spectrum block can be accessed or the processing or display parameters of any other block Configuring the SPECTRAN V6 RSA The Spectran V6 block p...

Страница 6: ...hannels Receiver Select Output Format Receiver Clock Start Stop Connect Disconnect Center Frequency RF Amplifier Frequency Profile Status Display Span Attention Changing these parameters can result in...

Страница 7: ...nfigurations One of the simplest missions possible The mission begins with a calibration block on the left in the blockgraph editor see picture above To specify which cable antenna and or other RF equ...

Страница 8: ...tion does not support USB 3 SuperSpeed Please make sure the port is con nected to a USB 3 x port on the PC or the cable does support the USB 3 SuperSpeed standard The current measurement parameters ar...