Dear Customers 

 

Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors 
available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen.   

We recommend that you read through this manual carefully before using the device for the first time. 

 

Preliminary Remarks 

 

 

This device conforms to the European Directive 93/42 EEC for Medical Products. This is made evident by the 

       

  mark of conformity. (0123: The reference number to the involved notified body) 

 

The device is designed for use on adults only, not newborns or infants. 

 

Environment for use 
The device is for use in the home healthcare environment.

 

 

This device is designed to measure blood pressure and pulse rate of people for diagnosis. 

 

Precautions 

 

 

Precision components are used in the construction of this device. Extremes in temperature, humidity, direct 
sunlight, shock or dust should be avoided. 

 

Clean the device and cuff with a dry, soft cloth or a cloth dampened with water and a neutral detergent. Never 
use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff. 

 

Avoid tightly folding the cuff for long periods, as such treatment may shorten the life of the components. 

 

The device and cuff are not water resistant. Prevent rain, sweat and water from soiling the device and cuff. 

  Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, 

X-ray or other devices with strong electrical fields. 

Содержание UB-510

Страница 1: ...Wrist Digital Blood Pressure Monitor Model UB 510 1WMPD4001955A...

Страница 2: ...urement 7 Measurements 8 Normal Measurement 8 Notes For Proper Measurement 9 Operation Mode 9 What Is An Irregular Heartbeat 10 Pressure Bar Indicator 10 WHO Classification Indicator 11 About Blood Pr...

Страница 3: ...r use in the home healthcare environment This device is designed to measure blood pressure and pulse rate of people for diagnosis Precautions Precision components are used in the construction of this...

Страница 4: ...r proper use of the device Do not apply the cuff to an arm with another medical electrical equipment attached The equipment may not function properly People who have a severe circulatory deficit in th...

Страница 5: ...3 Parts Identification...

Страница 6: ...ny excessivebodymovementisdetectedduringthemeasurement Previous measurements stored in MEMORY FullBattery The battery power indicator during measurement lowBattery The battery is low when it blinks Re...

Страница 7: ...ice 2 Insert two AAA LR03 size batteries in the battery compartment with positive and negative terminals matching those indicated on the battery compartment 3 Slide the battery cover back on the devic...

Страница 8: ...atteries may leak and cause a malfunction Use the specified batteries only The batteries provided with the device are for testing the monitor performance and may have a shorter life 2 Fastening the Cu...

Страница 9: ...ath We recommend you to rest 20 or 30 minutes before taking measurement Measure your blood pressure at about the same time every day 4 Measurement During measurement it is normal for the cuff to feel...

Страница 10: ...starts to inflate It is normal for the cuff to feel very tight Note If you wish to stop inflation at any time press the START button again 3 The measurement starts automatically when pressurizing star...

Страница 11: ...measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Should the device detect a condition that is abnormal it wil...

Страница 12: ...rtbeat is defined as a heartbeat that varies by 25 from the average of all heartbeats during the blood pressure measurement It is important that you be relaxed remain still and do not talk during meas...

Страница 13: ...amental pressure which is measured first thing in the morning while one is still at rest and before eating What Is Hypertension And How Is It Controlled Hypertension an abnormally high arterial blood...

Страница 14: ...rd to age have been established by the World Health Organization WHO as shown in the chart on the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seasonal...

Страница 15: ...ed your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Raise your hand so that the cuff...

Страница 16: ...llometric measurement Clinical test According to ANSI AAMI SP 10 1992 Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute EMC IEC 60601 1 2 2007 Measurement accuracy Pressure 3 mmHg Pulse...

Страница 17: ...on Business Park Abingdon Oxfordshire OX14 1DY United Kingdo Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263...