manualshive.com logo in svg
background image

 

English  10

 

Measurements 

 

Measurement With The Desired Systolic Pressure 

 

If your systolic pressure is expected to exceed 230 mmHg, use this 
procedure. 

 

1.  Place the cuff on the arm (preferably the left arm).   

 

2.  Press and hold the 

START

 button. 

Release the button when the average 
of all the data in memory is displayed. 
Press and hold the START button 
again until a number about 30 to 40 
mmHg higher than your expected 
systolic pressure appears.   

 

3. Release the 

START

 button to start 

measurement, when the desired 
number is reached. Then continue to 
measure your blood pressure as 
described on the previous page. 

 
 

Notes For Proper Measurement 

  Sit down in a comfortable position. Place 

the arm to be used for the measurement 

on a table or other support so that the 

center of the cuff will be at the same 

height as your heart. 

 

  Relax for about five or ten minutes before taking a measurement. If you 

are excited or depressed by emotional stress, the measurement will 

reflect this stress as a higher (or lower) than normal blood pressure 

reading and the pulse reading will usually be faster than normal. 

 

  An individual's blood pressure varies constantly, depending on what you 

are doing and what you have eaten. What you drink can have a very 

strong and rapid effect on your blood pressure. 

 

  This device bases its measurements on the heartbeat. If you have a very 

weak or irregular heartbeat, the device may have difficulty determining 

your blood pressure. 

 

  Should the device detect a condition that is abnormal, it will stop the 

measurement and display an error symbol. Refer to page 4 for the 

description of the symbols. 

 

  This blood pressure monitor is intended for use by adults only. Consult 

with your physician before using this device on a child. A child should not 

use this device unattended. 

Refer to the previous page 

for measurement 

Press and hold the button

At heart level 

Release the button 

at the desired 

systolic pressure 

START

START

Press and hold the button

Release the button 

when the average   

is displayed. 

Starts inflation 

Содержание UA-851

Страница 1: ...Digital Blood Pressure Monitor Model UA 851 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung 1WMPD4001437A...

Страница 2: ...ter Measurement 8 Measurements 9 Normal Measurement 9 Measurement With The Desired Systolic Pressure 10 Notes For Proper Measurement 10 Recalling Memory Data 11 Clearing the memory data 11 What Is An...

Страница 3: ...r use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean...

Страница 4: ...TART Button Blue illumination Air Connector Plug Air Socket Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Systolic Pressure Pulse Rate Battery Indicator I H B Indicato...

Страница 5: ...ing the measurement Previous measurements stored in MEMORY FullBattery The battery power indicator during measurement LowBattery The battery is low when it blinks Replace all batteries with new ones w...

Страница 6: ...T button After all of the display segments the average of the stored data is displayed Release the START button Then the data number of the most recent measurement and the data are displayed Automatic...

Страница 7: ...RY mark does not appear when the batteries are drained Battery life varies with the ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided w...

Страница 8: ...ended Cuff Size Order No 32 cm to 45 cm Large cuff UA CUFDBKLA EC 22 cm to 32 cm Medium cuff UA CUFDBKAU EC Small cuff Arm size The circumference at the biceps Note This UA 851 monitor is NOT designed...

Страница 9: ...t after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement During measurement it is n...

Страница 10: ...time press the START button again 3 When inflation is complete deflation starts automatically and heart mark blinks indicating that the measurement is in progress Once the pulse is detected the mark b...

Страница 11: ...ed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood p...

Страница 12: ...the data are displayed Automatically the older data are displayed in turn 3 After the last data are displayed the power is turned off automatically Note Pressing the START button during the recalling...

Страница 13: ...this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator Each segment of the bar indicator corresponds to the WH...

Страница 14: ...regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 2...

Страница 15: ...etely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain ve...

Страница 16: ...nce Technical Data Type UA 851 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg or 2 whichever is grea...

Страница 17: ......

Отзывы: