background image

 

English  20

 

What Is The IHB/AFib Indicator? 

 

 

When the monitor detects an irregular rhythm during the measurements, 

the IHB/AFib indicator will appear on the display with the measurement 

values.   

 

 

Note:  We  recommend  contacting  your  physician  if  you  see  this 

 

IHB/AFib indicator frequently. 

 

 

  What Is The AFib? 

 

 

The heart contracts due to electrical signals occurring in heart and sends 

blood through the body. Arterial fibrillation (AFib) occurs when the electrical 

signal  in  the  atrium  becomes  confused  and  leads  to  disturbances  in  the 

pulse  interval.  AFib  can  cause  blood  to  stagnate  in  the  heart,  which  can 

easily create clots of blood, a cause of stroke and heart attack. 

 

IHB/AFib 

 

%IHB/AFib is displayed as frequency of IHB/AFib detected. 

IHB/AFib can detect not only noises such as physical movement but also 

an  irregular  heartbeat.  Therefore,  we  recommend  contacting  your 

physician

 

if %IHB/AFib level is high.

 

 
 
 
 
 
 

Display of %IHB/AFib: %IHB/AFib  is  displayed  when  displaying  average  values. 

(Refer to “2. Recalling the Data” in “Operation Mode”) 

%IHB/AFib is not displayed when the memory number is six or less.

 

Average value display

 

 
 
 
 
 
 
 
 
 
 

 

Level 0 

%IHB/AFib=0

 

Level 1 

%IHB/AFib=1 - 9

 

Level 2 

%IHB/AFib=10 - 24

Level 3 

%IHB/AFib=25 - 100

 

Not displayed 

 
 

 

 

 

%IHB/AFib = 

x 100 [%] 

Number of detected 

IHB/AFibs in memory 

Total number 

Содержание UA-767JP

Страница 1: ...Digital Blood Pressure Monitor Model UA 767JP Instruction Manual Original 使用手冊 翻譯 사용설명서 번역본 ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺩﻟﻳﻝ ﺗﺭﺟﻣﺔ 1WMPD4002956B English 한국어 中文 ﻋﺭﺑﻲ ...

Страница 2: ... Measurement 15 After Measurement 15 Measurements 16 Normal Measurement 16 Measurement with the Desired Systolic Pressure 17 Notes for Accurate Measurement 17 Recalling the Memory Data 18 What Is The IHB AFib Indicator 20 What Is The AFib 20 IHB AFib 20 Pressure Bar Indicator 21 WHO Classification Indicator 21 About Blood Pressure 22 What is Blood Pressure 22 What is Hypertension and How is it Con...

Страница 3: ...irect sunlight shock or dust should be avoided Clean the device and cuff with a dry soft cloth or a cloth dampened with water and a neutral detergent Never use alcohol benzene thinner or other harsh chemicals to clean the device or cuff Avoid tightly folding the cuff or storing the hose tightly twisted for long periods as such treatment may shorten the life of the components Take care to avoid acc...

Страница 4: ...use the device in a place within the reach of infants It may cause accidents or damage There are small parts that may cause a choking hazard if swallowed by mistake by infants Unplug the AC adapter when not in use during the measurement Use of accessories not detailed in this manual may compromise safety Should the battery short circuit it may become hot and potentially cause burns Allow the devic...

Страница 5: ...It may cause injury or accidents Do not use the device where flammable gases such as anesthetic gases are present It may cause an explosion Do not use the device in highly concentrated oxygen environments such as a high pressure oxygen chamber or an oxygen tent It may cause a fire or explosion ...

Страница 6: ...re Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator Heart Mark 1 5V Batteries R6P LR6 or AA Date Clock Display SET Button Button Button IHB AFib symbol Movement Error Symbol Cuff Fit Error Symbol Average START Button Proper Fit Range Index Mark Artery Position Mark Battery Cover Display IHB AFib User AC Adapter Plug ...

Страница 7: ...cture IP International protection symbol WEEE label SN Serial number Refer to instruction manual booklet Polarity of DC jack Keep dry Symbols that appear on the display Symbols Function Meaning Recommended Action Appears while measurement is in progress It blinks when the pulse is detected Measurement is in progress Remain as still as possible IHB AFib symbol Appears when an irregular heartbeat is...

Страница 8: ... blood pressure due to movement during measurement Takeanothermeasurement Remain very still during measurement The systolic and diastolic values are within 10 mmHg of each other Apply the cuff correctly and take another measurement The pressure value did not increase during the inflation The cuff is not applied correctly PUL DISPLAY ERROR The pulse is not detected correctly Blood pressure monitor ...

Страница 9: ...ata in memory The average of all measurements is displayed as indicated in the figure at the right Then each time the button is pressed the memory data is displayed as follows Most recent data No n in the example No 35 Last data No 1 For details on recalling the data refer to Recalling the Memory Data 3 Changing User for Memory Display Press the SET button while a memory is displayed The user is c...

Страница 10: ...and hold both the and buttons until the illuminated mark starts blinking 5 Measurement with the Desired Systolic Pressure Refer to page 17 for measurement with the desired systolic pressure 6 User Selection Press the SET button before measuring blood pressure to select a user from 1 to 4 In standby mode press the SET button Each time the SET button is pressed the user changes Press the START butto...

Страница 11: ...alfunction Replace the batteries two seconds or more after the device turns off If LOW BATTERY mark appears even after the batteries are replaced make a blood pressure measurement The device may then recognize the new batteries LOW BATTERY mark does not appear when the batteries are drained The battery life varies with the ambient temperature and may be shorter at low temperatures Generally four n...

Страница 12: ... connect the AC adapter to an electrical outlet Use the specified AC adapter Refer to page 25 When disconnecting the AC adapter from the electrical outlet grasp and pull the AC adapter body out of the outlet When disconnecting the AC adapter plug from the blood pressure monitor grasp and pull the AC adapter plug out of the monitor Air connector plug Air socket AC adapter plug DC jack ...

Страница 13: ...g the or button Press the SET button to set the current hour and move to minute selection 6 Select the minute using the or button Press the START or SET button to turn the device off Holding down the or button will change the value continuously Note After three minutes of non operation the device will turn off automatically When the clock has not been set the clock display indicates dashes as show...

Страница 14: ...ize Recommended Cuff Size Catalog Number 31 cm to 45 cm Large Adult Cuff CUF F LA 22 cm to 42 cm Wide Range Cuff CUF I 22 cm to 32 cm Adult Cuff CUF F A Arm size The circumference at the biceps Note Model UA 767JP is not designed for using a small cuff Applying the Arm Cuff 1 Wrap the cuff around the upper arm about 1 2 cm above the inside of the elbow as shown Place the cuff directly against the ...

Страница 15: ... Over range printed on the adult cuff and wide range cuff Use the large adult cuff instead of the adult cuff or wide range cuff Proper fit range for the wide range cuff It s printed on the wide range cuff Proper fit range for the large adult cuff It s printed on the large adult cuff Under range printed on the adult cuff and wide range cuff Under range printed on the large adult cuff Use the adult ...

Страница 16: ... keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement During measurement it is normal for the cuff to feel very tight Do not be alarmed After Measurement After measurement press the START button to turn the device off After ...

Страница 17: ...ng that the measurement is in progress Once the pulse is detected the mark blinks with each pulse beat Note If an appropriate pressure is not obtained the device starts to inflate again automatically To avoid re inflation see Measurement with the Desired Systolic Pressure on the next page 5 When the measurement is complete the systolic and diastolic pressure readings and pulse rate are displayed T...

Страница 18: ...ed or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure varies constantly depending on what you are doing and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device bases its measu...

Страница 19: ...the reverse order is pressed the memory data is displayed as follows Most recent data No n in the example No 35 Three seconds after the data number display the measurement data is displayed Last data No 1 Three seconds after the data number display the measurement data is displayed 3 After the last data is displayed press the button to return the average display of all measurements Average of all ...

Страница 20: ... SET button to change the user and display the memory display for that user 5 Press the START button to turn the device off After one minute of non operation the device will turn off automatically User 1 User 3 User 2 User 4 ...

Страница 21: ...val AFib can cause blood to stagnate in the heart which can easily create clots of blood a cause of stroke and heart attack IHB AFib IHB AFib is displayed as frequency of IHB AFib detected IHB AFib can detect not only noises such as physical movement but also an irregular heartbeat Therefore we recommend contacting your physician if IHB AFib level is high Display of IHB AFib IHB AFib is displayed ...

Страница 22: ...assification described on the next page WHO Classification Indicator Severe hypertension Moderate hypertension Mild hypertension High normal Normal Optimal The indicator displays a segment based on the current data corresponding to the WHO classification Inflation complete Pressurizing Inflation in progress Measurement in progress Releasing air Example Moderate hypertension Mild hypertension High ...

Страница 23: ...e regular physical checkups Maintain proper weight Why Measure Blood Pressure at Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 25 to 30 mmHg higher than that measured at home Home measurement reduces the effects of outside influences on blood pressure readings supplements the doctor s readings and provides a more accurate com...

Страница 24: ...e mark does not appear Replace all batteries with new ones The device does not measure Readings are too high or too low The cuff is not applied properly Apply the cuff correctly You moved your arm or body during measurement Make sure you remain very still and quiet during measurement The cuff position is not correct Sit comfortably and still Place your arm on a table with your palm facing upward a...

Страница 25: ...ement range Pressure 0 299 mmHg Systolic pressure 60 279 mmHg Diastolic pressure 40 200 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Power supply 4 x 1 5V batteries R6P LR6 or AA or AC adapter TB 233C Not included Number of measurements Approx 700 times LR6 alkaline batteries Approx 200 times R6P manganese batteries With pressure value of 180 mmHg at room temperature...

Страница 26: ...nction Meaning For indoor use only Class II device Thermal fuse Fuse EC directive device label EAC certification device label Polarity of AC adapter plug Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C Note Specifications are subject to change without prior notice IP classification is degrees of protection provided by e...

Страница 27: ...English 26 MEMO ...

Страница 28: ...3 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 OOO A D RUS OOO ЭЙ энд ДИ РУС 121357 Российская Федерация г Москва ул Верейская дом 17 Business Center Vereyskaya Plaza 2 121357 Russian Federation Moscow Vereyskaya Street 17 тел 7 495 937 33 44 факс 7 495 937 55 66 A D Technology Trading Shanghai Co Ltd 爱安德技研贸易 上海 有限公...

Отзывы: