8

 

Using The Monitor 

Applying The Arm Cuff 

1. Wrap the cuff around the upper arm, about 

1 to 2 cm above the elbow, as shown. 

Place the cuff directly against the skin, as 

clothing may cause a faint pulse and result 

in a measurement error. 

 

2. Constriction of the upper arm, caused by 

rolling up a shirtsleeve, may prevent 

accurate readings. 

 

3. Confirm that the index

 

 

points within the 

proper fit range. 

 
 
 
 
 

How To Take Proper Measurements 

  For the most accurate blood pressure measurement: 

  Sit comfortably on a chair. Rest your arm on the table. Do not cross your legs. 

Keep your feet on the floor and straighten your back. 

  Relax before measurement. 

  Place the center of the cuff at the same height as your heart. 

  Remain still and keep quiet during measurement. 

  Do not measure immediately after physical exercise or a bath. Rest before 

taking the measurement. 

  Try to measure your blood pressure at the same time every day. 

 
 

Measurement 

  During measurement, it is normal for the cuff to feel very tight. (Do not be alarmed) 

 
 

After Measurement 

  After measurement, press the 

 START 

  button to turn off the power.   

Remove the cuff and record your data. 

 

Note: The device has an automatic power shut-off function, which turns the power 

off approximately two minutes after measurement. 

Allow at least three minutes between measurements pn the same person. 

 

 

Do not roll up shirtsleeve tightly

1 to 2 cm 

Air hose

Cuff

Index

 

 

and Proper fit range

Artery position mark

Secure the fabric 

fastener firmly 

Содержание UA-621

Страница 1: ...Digital Blood Pressure Monitor Model UA 621 Instruction Manual 1WMPD4001898D...

Страница 2: ...ring Data 11 What Is An Irregular Heartbeat 12 Pressure Bar Indicator 12 WHO Classification Indicator 12 About Blood Pressure 13 What Is Blood Pressure 13 What Is Hypertension And How Is It Controlled...

Страница 3: ...es X ray or other devices with strong electrical fields Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulat...

Страница 4: ...pressure oxygen chamber or an oxygen tent It may cause a fire or explosion Parts Identification Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Battery Indicator I H B...

Страница 5: ...ry The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Страница 6: ...ory automatically 2 Recalling Data Refer to page 11 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are...

Страница 7: ...ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Remo...

Страница 8: ...cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 621 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action A...

Страница 9: ...ent Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest before taking the mea...

Страница 10: ...p inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse...

Страница 11: ...tional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure v...

Страница 12: ...1 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed 2 The data are automatically displayed...

Страница 13: ...Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator...

Страница 14: ...uce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can p...

Страница 15: ...batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measure...

Страница 16: ...Type UA 621 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Number of measurements Approximat...

Страница 17: ...33C Input 100 240V Output 6V 500mA TB 233BF Input 240V Output 6V 500mA Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C TB...

Страница 18: ...ingdon Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D Australasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 6...

Отзывы: