A&D FS-03i Скачать руководство пользователя страница 3

- 2 - 

1. OP-02 BATTERY 

 

1-1. Using the OP-02 SLA Battery

 

‰

 The scale can be operated with an SLA (Sealed Lead Acid) battery that will be 

commercially available. 

‰

 The scale (with no other options) can be operated with a fully charged battery for; 

LCD backlight OFF and Comparator light OFF: approximately 80 hours 
LCD backlight OFF and Comparator light ON: approximately 55 hours 
LCD backlight ON and Comparator light ON: approximately 25 hours 

‰

 The battery will take about 15 hours to be fully charged. 

‰

 The battery life will vary depending on how the scale is used, the ambient 

temperature and so on.

 

 
 
 
 
 
 
 
 
 

Installing the battery

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

‰

 Use a Yuasa Battery NP4-6 (6V, 4Ah). 

‰

 There will be risk of explosion if the battery is connected

improperly or replaced with the incorrect type. 

‰

 Dispose of a used battery according to the local laws and

regulations. 

Hexagon head screws

Do not remove
rubber O-rings.

M3x8 screws 

Battery support

Battery NP4-6

“+” electrode (RED)

“+” (RED) wire

“-” (BLACK) wire

“-” electrode (BLACK)

Rear cover

Содержание FS-03i

Страница 1: ...WM PD4001368 F FS S i i S Se er ri ie es s C Ch he ec ck k W We ei ig gh hi in ng g S Sc ca al le es s O Op pt ti io on n OP 02 OP 03 OP 04...

Страница 2: ...stitute Product Safety Signs and Labels The meanings are as follows WARNING A potentially hazardous situation which if not avoided could result in death or serious injury CAUTION A potentially hazardo...

Страница 3: ...Comparator light ON approximately 25 hours The battery will take about 15 hours to be fully charged The battery life will vary depending on how the scale is used the ambient temperature and so on Ins...

Страница 4: ...power cord again and check that the scale still works Charging the battery When the weight display shows lb1 the battery voltage is low in voltage and should be recharged Connect the main power cord...

Страница 5: ...utputs for comparator result are obtained The OP 03 unit includes an interface board a connector cable a cable gland and two screws M3x6 2 1 Installation Ten hexagon screws Rear cover Connector cable...

Страница 6: ...cluded in the OP 03 6 Tighten the cable gland and attach the rear cover to the front display firmly using the ten hexagon bolts 7 Connect the main power cord to the outlet 8 Set the function parameter...

Страница 7: ...ts _ k g Weighing unit kg _ _ g Weighing unit g _ l b Weighing unit lb _ o z Weighing unit oz _ _ HI LO limit F07 2 Example of data Weighing data kg S T 0 0 1 2 3 4 5 _ k g CR LF Weighing data g S T 0...

Страница 8: ...ccur until after the weight display falls below 5d Auto print Mode data F06 4 Data is sent if the weight display is stable at 5d d weighing display division and above below The next transmission can n...

Страница 9: ...mory number Examples of command and reply _ shows Space 20H Examples below are for F20 0 Reply to command is sent Request a weight data Command Q C LF Reply S T 0 0 1 2 3 4 5 _ k g C LF Stable Positiv...

Страница 10: ...LF Send a target weight in use Command O K C LF Reply O K 0 0 0 1 0 0 0 _ k g C LF Send a HI limit value or upper limit weight in use Command H I C LF Reply H I 0 0 0 3 0 5 0 _ k g C LF Upper limit w...

Страница 11: ...0 C LF Decimal point follows the weight display Reply L O 0 0 0 1 0 0 C LF FS 15Ki F07 0 0 100 kg will be set as a lower limit weight F07 1 0 100 kg will be set as a LO limit weight F07 2 is set the c...

Страница 12: ...ed memory number No reply for F20 1 Command C M 0 1 C LF Clear the contents of memory number 01 Reply C M 0 1 C LF Reply in case of the function setting F20 0 There are other replies to the commands o...

Страница 13: ...ta Code WT Weight CM Comma 2CH TR Tare weight in use SP Space 20H CP Comparator result CR CR 0DH OK Target weight LF LF 0AH HI HI limit value or upper limit weight LO LO limit value or lower limit wei...

Страница 14: ...ata 3 digit unit TR _ _ _ 1 2 3 4 _ k g 1 234 kg 9 digit tare data 3 digit unit CP O K Comparator result OK 2 characters H I Comparator result HI 2 characters L O Comparator result LO 2 characters _ _...

Страница 15: ...s an interface board a connector cable two cable glands and two screws M3x6 The relay output specifications are same as the OP 03 See 2 2 OP 03 Specifications 3 1 Installation Ten hexagon screws Rear...

Страница 16: ...mission form Asynchronous bi directional half duplex Data format Baud rate 2400 4800 9600 bps Data 7 bits parity 1bit even odd or 8 bits non parity Start bit 1 bit Stop bit 1 bit Code ASCII Terminator...

Страница 17: ...f the scale to send a command at the head of command of the RS 232C All of data or reply from the scale have at the head Connect TRM with RDB at the farthest FS i from the host computer Host computer...

Страница 18: ...nd 2 3 Q C LF Reply 2 3 S T 0 0 1 2 3 4 5 _ k g C LF Stable data 2 3 U S 0 0 0 7 8 9 0 _ k g C LF Unstable data 2 3 O L 9 9 9 9 9 9 9 _ k g C LF E display Zero the scale No reply for F20 1 Command 2 3...

Отзывы: