5.3.

 

Connecting the wires

CAUTION

During wiring operations, use care so that water will not enter the box interior. 
Make sure the cable shield is grounded. Otherwise, the box performance will be unstable 
and readings may not be accurate. 

Connect the wires to the terminal block. As the terminal block is a spring clamp type, connecting wires is 
simple and no compression lug is required. For the wiring procedure, refer to Fig.3 

Fig.3 Terminal wiring procedure 

Connect the wire from the load cell or a weighing indicator according to Table 1. The wire color matches the 
wiring color of A&D digital load cell. 
No particular terminal block is assigned to connect load cells or a weighing indicator. Use any terminal 
block.

 

Table 1 Terminal assignment and wire color 

Terminal (Top view) 

 

No.  1 

 

RED 

GRN 

YEL 

POW+    DATA+    SHD 

WHT    BLU 

POW -    DATA -

 

No. 

Symbol 

RED  

POW+ 

WHT  

POW- 

GRN  

DATA+ 

BLU  

DATA- 

YEL  

SHD 

Wire Color 

Red (R)  White(W)  Green(G)  Blue (B)  Yellow(Y) 

Connection 

Power 

Power 

supply(-) 

Data ( + )  Data ( - ) 

Shield 

5.4.

 

Tightening the cable glands and attaching the cover

CAUTION

After the cables are connected, tighten the cable glands firmly. Insufficient tightening will 
allow water to enter the box interior and result in a malfunction. 

 Tighten the screws to secure the cover firmly. Insufficient tightening will allow water to 

enter the box interior and result in a malfunction. 

When wiring operations are complete, check each connection to make sure it is correct. Then, tighten the 
cable glands firmly and attach the cover securely by tightening the screws firmly. Insufficient tightening will 
allow water to enter the box interior and result in a malfunction.

 

Wire insert port 

Содержание AD-4388 Series

Страница 1: ...MSAWT001 1 AD 4388 AD 4388 series Junction box for digital load cells Instruction Manual AD 4388 4 for four load cells AD 4388 6 for six load cells 1WMPD4001535B...

Страница 2: ...ompany Limited All rights reserved No part of this publication may be reproduced transmitted transcribed or translated into any language in any form by any means without the written permission of A D...

Страница 3: ...4 SPECIFICATIONS 12 5 USING THE JUNCTION BOX 13 5 1 Installing the junction box 13 5 2 Inserting the cables 13 5 3 Connecting the wires 14 5 4 Tightening the cable glands and attaching the cover 14 6...

Страница 4: ...4...

Страница 5: ...5...

Страница 6: ...6 mm 45 8 3 48 4 3 10 1...

Страница 7: ...7 No 1 2 3 4 5 RED GRN YEL POW DATA SHD WHT BLU POW DATA No 1 2 3 4 5 RED POW WHT POW GRN DATA BLU DATA YEL SHD...

Страница 8: ...8 100 C1 R1 JP1 100 C1 R1 JP1 JP1 AD4388 6 AD 4388 4...

Страница 9: ...9 100 C1 R1 JP1 100 C1 R1 JP1...

Страница 10: ...10 mm 175 45 157 MAX 30 25 22 74 MAX 187 127 109 25 175 45 157 MAX 30 25 22 74 MAX 187 127 109 25 45...

Страница 11: ...precautions and be sure to observe them In addition read the instruction manual thoroughly before using the junction box CAUTION Upon receipt and before installation store the junction box where it wi...

Страница 12: ...gital load cells can be connected 4 SPECIFICATIONS Material Main unit polyester Cable gland polyamide Permissible temperature range 20 C to 80 C Mass AD 4388 4 approx 0 51 kg AD 4388 6 approx 0 56 kg...

Страница 13: ...over securing screw hole For detailed sizes refer to Fig 1 After installation keep the cover removed for internal wiring operations Unit mm Fig 1 Detailed view of the screw hole to secure the junction...

Страница 14: ...al assignment and wire color Terminal Top view No 1 2 3 4 5 RED GRN YEL POW DATA SHD WHT BLU POW DATA No 1 2 3 4 5 Symbol RED POW WHT POW GRN DATA BLU DATA YEL SHD Wire Color Red R White W Green G Blu...

Страница 15: ...the jumper JP1 in the junction box installed furthermost from the weighing indicator as is and cut the jumpers JP1 in the other junction boxes using nippers Fig 4 shown below is an example connection...

Страница 16: ...ircuit diagram Power supply Power supply Data Data Shield 100 C1 R1 JP1 R W G B Y R W G B Y R W G B Y R W G B Y R W G B Y 100 C1 R1 JP1 R W G B Y R W G B Y R W G B Y R W G B Y R W G B Y R W G B Y Powe...

Страница 17: ...17 9 EXTERNAL DIMENSIONS AD 4388 4 AD 4388 5 Unit mm Fig 6 External dimensions 175 45 157 MAX 30 25 22 74 MAX 187 127 109 25 175 45 157 MAX 30 25 22 74 MAX 187 127 109 25 45...

Страница 18: ...18 MEMO...

Страница 19: ...IA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bldg 33 Gukjegeumyung ro 6 gil Yeongdeungpo gu Seoul 07331 Korea 82 2 780 4101 82 2 782 4264 OOO A D RUS O...

Страница 20: ......

Отзывы: