background image

 

  If the tower site is located on the soft soil, you will need to have a tamped 

area of no less than 30” diameter to prevent the foundation from shifting 
and caving. 

 

If the tower site is located on the loose sand, dig a hole of 30” in diameter 
and 5 feet deep. Fill the base with 2 feet of compressed rock or clay, tamp 
that down, and add 2 feet of concrete. Once the concrete sets, fill the hole 
with soil.

 

 

 
 

 

Construction Specification Layout of Tower for Wind Turbine-Guyed Tower 

 
 

 

 

The tower base pad layout 

Содержание PowerMax+ 400

Страница 1: ...INSTALLATION MANUAL 400W OFF GRID TURBINE...

Страница 2: ...with a mass distribution that ensures the rotors operate with nearly no noise and minimal vibration Wind Solar hybrid controller to work with both wind turbine and solar panels Low Start up and cut in...

Страница 3: ...1 Package Contents Check the crate packaging Call your PowerMax reseller to report any damage or missing parts...

Страница 4: ...shown in above picture We stock either a Weld on Ring Collar or bolt on pole collar Part Number Description Quantity Usage 1 Generator Assembly 1 2 Rotor Blade 3 3 Rotor Hub 1 4 Front Cover 1 5 Front...

Страница 5: ...to 70 85 Nm 2 3 Mounting the Rotor Blades 1 Blades should be in front of the rotor hub with the flat side facing upwind 2 Insert three bolts in the holes on the hub and blade Place flat washers on the...

Страница 6: ...3 Assemble the wind turbine rotor hub 4 Attach the wind turbine rotor blades 5 Attach the wind turbine front cover 6 Secure the wind turbine screw cover...

Страница 7: ...ven if this means placing the turbine farther away from the load than originally planned the increased efficiency of your machine will more than make up for any loss due to distance 4 Tower Recommenda...

Страница 8: ...ing and caving If the tower site is located on the loose sand dig a hole of 30 in diameter and 5 feet deep Fill the base with 2 feet of compressed rock or clay tamp that down and add 2 feet of concret...

Страница 9: ...cations PowerMax 400 PowerMax 600 Height of Tower Tower Diameter Tower Diameter Tower Wall Thickness Radius of Guy Wire 8 meters 80mm 100mm 3 5mm 4 6m 6 meters 60mm 80mm 3 4mm 4m Dimension of Tower Ba...

Страница 10: ...5 Cable Wiring The basic wiring diagram of single PowerMax system is as shown...

Страница 11: ...eters 100 150 meters Cable Size 12 AWG 4mm2 10 AWG 6mm2 8 AWG 10mm2 6 Maintenance The PowerMax is a very reliable series and is designed to run for long periods without any maintenance under severe co...