Allied Analogic, Inc.
1
Copyright © 2018
OVERVIEW
TriTone Transmitter 3 is designed for identifying cables and cable pairs by
generating identification tone at 577.5Hz or 987Hz at one of three amplitudes;
Normal, High, and Maximum. TriTone 3 provides Simplex and Triplex tone modes
allowing the user to select the best mode for the application.
The TriTone Transmitter 3 is used with existing amplifier probes; filtered, tunable,
or unfiltered; aerial coils; and hand coils that are compatible with 577.5 Hz or 987
Hz. The AALogic DAP-125 is ideal when identifying pairs using the TRI-PLEX
mode.
The TriTone Transmitter 3 includes automatic visual and audible short indications
to assist in confirming the correct pair is identified.
CONNECTIONS
The TriTone Transmitter 3 has a Pair Cord, with Red and Black needle clips, and a
Ground Cord. Connect the Pair Cord assembly and the Ground Cord to the jacks
located on the top of the TriTone Transmitter 3.
The clips and ground should be connected to the pair and shield of the cable as
needed.
Pair Identification, SMPLX
1T, SMPLX 3T, and TRI-
PLEX
Black clip to Tip, Red clip to
Ring, and Ground clip to
shield/ground
Pair Identification, Metallic Ground clip to Tip and Red
Clip to Ring
Pair Cord
Ground Cord