Aalberts DSI DRAFT 2 GO S Скачать руководство пользователя страница 2

 

S- & D-Type / EN 

Seite  2/4 
Version-5 

 

 

 

Draft2Go S- & D-Type/ Well & Draft 

Dispensing Unit from DSI for Schäfer-Kegs 

 

General 

The  dispensing  unit  offers  a  compact  and  simple  solution  for  mobile  dispensing  from  a  keg.  For  this  purpose,  the  suitable 
dispensing head is installed with an already preset pressure reducer incl. quick-connect coupling for the gas supply from the 
pressure  tank  (7  bar)  of  the  keg  and  a  compensator  dispensing  tap.  For  operating  the  Draft-2-Go  Tap  unit  you  need  basic 
knowledge of tapping beer and you have to respect to mentioned details in this instruction. For Service or repair of the unit, ask 
us or a qualified dispense system technician. 

 

Installation 

Before  initial  startup,  you  must  rinse  the  components  under  clean  water  to  remove  any  production  residues.  To  do  this, 
thoroughly rinse the dispense head (1) and the tap (2) in the beverage-touched areas as shown. (see chapter: Cleaning/Service) 
 
To assemble your D2G dispensing unit, proceed as follows: Take the dispense head (1) incl. 
pre-mounted pressure reducer (4) out of the packaging and mount the tap incl. shank (2) 
on the side outlet of the dispense head (1). The alignment of the tap can be done later at 
the  knurled  nut  between  tap  and  shank.  Now  take  the  plug-in  coupling  (3)  incl.  pre-
assembled gas line and push the end of the line into the connection on the pressure reducer 
(4).  
Do not connect any gas supply other than the gas supply located in the keg and intended 
for this product. 
 

Instruction manual 

Now you can put the dispensing unit into operation. To 
do  this,  place  the  dispense  head  (1)  into  the  keg  from 
above by aligning the two notches. Then turn it clockwise 
against the stop so that it is locked on the Keg. To align 
the tap (2), you can swivel it to the left/right. Then push 
the plug-in coupling (3)  onto  the  gas  supply  on  the  keg 
until it fits. To do this, pull up the outer ring of the plug-
in coupling (3) and push it all the way down. The unit is 
now automatically supplied with gas and regulated to the 
required  pressure.  Please  check  the  gas-carrying 
connection  points  for  leaks.  The  dispense  head  (1)  can 
now  be  attached  to  the  keg  to  start  dispensing.  To  do 
this,  move  the  handle  of  the  dispense  head  (1) 
completely to the lower position until it locks into place.  
Be careful not to squeeze yourself during the operation. 
The  beverage  is  now  pressurized  and  ready  for 
dispensing. To remove the unit, proceed in reverse order. 
 
To tap the beverage/beer you can now start directly, thanks to the fixed gas pressure. 
Make sure that the keg is securely positioned so that it does not fall over when tapping.  

Отзывы: