10
IM 725 (1-02)
1. Product Category
U = Unit Ventilator
2. Product Identifier*
AVS = Floor, Face and Bypass Damper, Heat/Cool, Heat Only, Cool
Only
AVV = Floor, Valve Control, Hydronic or Electric Heat/Cool, Heat
Only, Cool Only
AVR = Floor, Valve Control, Hydronic or Electric Reheat/Dehumid
AVB = Floor, Face and Bypass Damper, Hydronic Reheat
* End panels not included; Ordered as accessory, shipped
separately boxed
3. Design Series
4 = D Design
4. Nominal Capacity, cubic feet per minute (cfm)
S07 = 750
S10 = 1000
S13 = 1250
S15 = 1500
5. Voltage, volts, phase, Hertz (v-Hz-ph)
A = 115-60-1
C = 208-60-1
G = 230-60-1
J = 265-60-1
D = 208-60-3
H = 230-60-3
K = 460-60-3
6. Cooling Options
U = 2-row Chilled Water/Hot Water, 2-pipe
D = 3-row Chilled Water/Hot Water, 2-pipe
E = 4-row Chilled Water/Hot Water, 2-pipe
F = 5-row Chilled Water/Hot Water, 2-pipe
1 = 2-row High Capacity Chilled Water/Hot Water, 2-pipe
2 = 3-row High Capacity Chilled Water/Hot Water, 2-pipe
3 = 4-row High Capacity Chilled Water/Hot Water, 2-pipe
4 = 5-row High Capacity Chilled Water/Hot Water, 2-pipe
G = Direct Expansion (DX)
S = 3-row Chilled Water
V = 2-row Chilled Water
W = 4-row Chilled Water
Y = 5-row Chilled Water
5 = 2-row High Capacity Chilled Water
6 = 3-row High Capacity Chilled Water
7 = 4-row High Capacity Chilled Water
8 = 5-row High Capacity Chilled Water
Z = None
7. Heating Options
00 = None
12 = Low Electric Heat, 3-element
13 = High Electric Heat, 6-element
65 = 1-row, Hot Water
66 = 2-row, Hot Water
67 = 3-row, Hot Water
68 = Low Capacity Steam
69 = High Capacity Steam
78 = Low Capacity Steam, Opposite End Drain
79 = High Capacity Steam, Opposite End Drain
Unit Ventilator (Floor Type) Data Plate - Specific Information
8. Hand Orientation [Right (RH) Left (LH)]
A = LH Both Coils (only w Controls by Others)
B = RH Both Coils (only w Controls by Others)
D = RH Electric Heating, One Coil
E = LH Heating, RH Cooling
F = RH Heating, LH Cooling
G = RH Electric Heating, LH Cooling
R = LH Single Coil
S = RH Single Coil
9. Controls
15 = MicroTech w Unit Mounted Sensor
16 = Part Load Variable Air MicroTech w Unit Mounted Sensor and
Humidity Sensor (if required)
19 = MicroTech for Remote Wall Sensor (accessory Sensor and
Humidity Sensor (required)
20 = Part Load Variable Air MicroTech for Remote Wall Sensor
(accessory Sensor/ Humidity Sensor required)
23 = Field Mounted Controls by Others
17 = Digital Ready/with Damper Acutators, (3)@ 10k NTC Sensors,
3 Terminal Strips, 75 VA 24 Volt T’fmr, w/o UV Controller
10. Discharge
AB = 21-7/8" Unit, Top Bar Grille Discharge, Full Adapter Back w
Closed Pipe Tunnel w Solid Back
AK = 21-7/8" Unit, Top Bar Grille Discharge, Partial Adapter Back w
Open Pipe Tunnel
AL = 16-5/8" Unit, Top Bar Grille Discharge
AM = 21-7/8" Unit, Top Bar Grille Discharge, 2" Stepdown Full
Adapter Back w Closed Pipe Tunnel
AN = 21-7/8" Unit, Top Bar Grille Discharge, Full Adapter Back w
Closed Pipe Tunnel
AP = 21-7/8" Unit, Top Bar Grille Discharge, Partial Adapter Back w
Closed Pipe Tunnel, Top Duct Intake
11. Return Air (RA) / Outside Air (OA)
22 = RA Bottom Front / OA Rear Duct Collar
24 = 100% RA Bottom Front / No OA Opening / No OA/RA Dampers
30 = RA Bottom Front w Draft Stop / OA Rear Duct Collar
12. Power Connection
G = Box w Switch
13. Color
B = Putty Beige
G = Soft Gray
I = Antique Ivory
W = Off White
14. SKU
B = Standard Delivery
C = Extended Delivery
15. Product Style
1
Field-Installed Accessories may accompany Unit Ventilator(s), or
may be shipped separately. These may include: Adapter Backs;
Aluminum Louvers; Aluminum Grilles; Auxiliary Drain Pans; Controls
/ Sensors; End Panels; Spare Filters; MicroTech Controls, Sensors
(temperature, humidity, CO
2
); End of Cycle DDC Valve; Modulating
DDC Valves; Subbases. See instructions shipped with accessories
and install according to these and the plans.
Field
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Model
U
AVS
4
S07
A
S
65
E
23
AL
22
G
B
C
1