background image

COPPA 2:  

INSTRUCTIONS 

FOR USE AND 

MAINTENANCE

Содержание COPPA 2

Страница 1: ...COPPA 2 INSTRUCTIONS FOR USE AND MAINTENANCE ...

Страница 2: ... circuit diagram 12 Notices Read the information in these operating instructions carefully and familiarize yourself with them Our company reserves all rights to the interpretation of these operating instructions The actual appearance is determined by the object Once they have been read the operating instructions should be kept safely together with the invoice Subject to upgrades of the product tec...

Страница 3: ...ht indicate different air quality Combo Filter Air intake Left hand clip Right hand clip Operator panel Power switch Display panel Digital PM2 5 concentration indicator temperature air humidity Light sensor The brightness of the operator panel adapts itself to the ambient brightness ...

Страница 4: ...urface area the copper containing filter reliably deactivates viruses and bacteria 3 Highly efficient HEPA filter Filters particles with a diameter greater than 0 1 µm e g pollen dust mites and other allergens 99 9 separation DIN EN 1822 5 2009 4 Activated charcoal filter Cleans the air and removes volatile organic compounds VOCs passive smoke formaldehyde benzene helium and other harmful gases 5 ...

Страница 5: ...ight goes out this means that the timer is switched off To activate the child lock press the Timer child lock symbol for 3 seconds in Operation mode The symbol then lights up During this time no other symbol can be actuated Press the symbol for another 3 seconds to unlock the device again The child lock is no longer lit up and all symbols are active again Wi Fi connection Press the Wi Fi symbol fo...

Страница 6: ...the corresponding symbols light up PM2 5 Display of the PM2 5 value in real time Temperature Display of the temperature in real time Air humidity Display of the air humidity in real time Filter service life The filter service life gradually decreases the display is reduced by one bar every 500 operating hours One bar corresponds to 500 hours of use OPERATOR PANEL Display The air quality check is a...

Страница 7: ... make sure that you have removed the packaging before using the device for the first time Put the upper part back into its original position and make sure that the clips click back into place Fig 4 Frequency of filter change Change the filter in accordance with the filter service life indicated in the display For hygienic reasons we recommend changing the filter at least 1 x per year Notice Make s...

Страница 8: ...use the device under supervision 3 Always unplug the device immediately in the event of an accident and do not use the device in a defective condition 4 To avoid hazards a damaged power cable may only be exchanged by the manufacturer or by qualified maintenance personnel 5 The manufacturer accepts no liability for damage resulting from failure to observe the maintenance and servicing specification...

Страница 9: ... toilet utility room or kitchen Please do not block the air inlet and outlet Please do not operate the air purifier without the filter inserted The filter cannot be cleaned or washed Only sockets with a voltage of 220 V may be used Please hold onto the mains connector firmly when unplugging it and do not pull on the power cable as this may result in an electric shock or short circuit When using th...

Страница 10: ...cribed below Adjust the receiving antenna or turn it Place the air purifier further away from the radio television receiver Connect the air purifier and television radio to separate sockets Contact the manufacturer or a qualified radio television technician if you require help The device is not suitable for persons with physical or mental handicaps or perception disorders or for children They may ...

Страница 11: ...n the room takes longer The device is installed in a confined area or there are obstacles in the vicinity with a detrimental effect on the cleaning performance The filter is clogged with a detrimental effect on the cleaning performance cleaning the filter or inserting a new one is recommended Odours from the air outlet Many people in the room smoke barbecue or perform some other task that creates an...

Страница 12: ...filter change 1 x per year Guarantee 3 years without filter commercial 1 year TECHNICAL DATA Certifications of the woven copper layer ISO18184 2019 06 viruses DIN EN ISO 20743 2013 12 bacteria DIN EN 14119 2003 12 microfungi The device must not be disposed of with household waste Electrical circuit diagram M Notice The positions in the electrical circuit diagram do not correspond to the actual pos...

Страница 13: ...278 452277 E sales jfilters com F 44 0 1278 450873 www room air purifier co uk Service Division 5 Stratfield Park Elettra Avenue Waterlooville Hampshire PO7 7XN Online Services Our Energy Rated products are available online at www jfilters com Filter Manufacture Air Hygiene Solutions Manufactured in the UK Delivered on time ...

Отзывы: