38 PCM-5890 User's Manual
Ethernet software configuration
The PCM-5890’s on-board Ethernet interface supports all major
network operating systems. I/O addresses and interrupts are easily
configured via the Award BIOS Setup. To configure the medium
type, to view the current configuration, or to run diagnostics, do
the following:
1. Power the PCM-5890 on. Ensure that the RSET8029.EXE file
is located in the working drive.
2. At the prompt type RSET8029.EXE and press <Enter>. The
Ethernet configuration program will then be displayed.
3. This simple screen shows all the available options for the
Ethernet interface. Just highlight the option you wish to
change by using the Up and Down keys. To change a selected
item, press <Enter>, and a screen will appear with the avail-
able options. Highlight your option and press <Enter>. Each
highlighted option has a helpful message guide displayed at the
bottom of the screen for additional information.
4. After you have made your selections and your are sure that
this is the configuration you want, press ESC. A prompt will
appear asking if you want to save the configuration. Press Y if
you want to save.
The Ethernet Setup Menu also offers three very useful diagnostic
functions. These are:
1. Run EEPROM test
2. Run Diagnostics on Board
3. Run Diagnostics on Network
Each option has its own display screen which shows the format
and result of any diagnostic tests undertaken.