3.4.7  Advanced: USB Configuration 

 

 

Options summary: 

Legacy USB Support   

Enabled 

Default 

Disabled 

 

Auto 

 

Enables BIOS Support for Legacy USB Support. When enabled, USB can be functional 

in legacy environment like DOS. 

AUTO option disables legacy support if no USB devices are connected 

 

 

 

 

Chapter 3 – AMI BIOS Setup 

 

60

 

Содержание FWS-7820

Страница 1: ...FWS 7820 Network Appliance User s Manual 1 st Ed Last Updated August 8 2016...

Страница 2: ...al is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its us...

Страница 3: ...icrosoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom is a trademark of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM PC...

Страница 4: ...r product please make sure the following items have been shipped Item Quantity FWS 7820 1 EAR bracket kit 1 Console cable 1 Product DVD 1 If any of these items are missing or damaged please contact yo...

Страница 5: ...criptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to fac...

Страница 6: ...dware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disconnect it fr...

Страница 7: ...f the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working as expected...

Страница 8: ...battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local gove...

Страница 9: ...Network Appliance FWS 7820 China RoHS Requirements CN AAEON Embedded Box PC Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006 Preface IX...

Страница 10: ...s Connectors for External Connections O O O O O O Chassis O O O O O O CPU RAM O O O O O O Hard Disk O O O O O O PSU O O O O O O O The quantity of poisonous or hazardous substances or elements found in...

Страница 11: ...nnector 1 0mm FPC 1 x 16P CN17 19 2 4 3 Key PAD Connector 2 54mm Pin Header 1 x 4P CN41 20 2 4 4 COM Port 2 0mm BOX Header 2 x 5P CN14 20 2 4 5 VGA Port 2 0mm Box Header VGA1 21 2 4 6 HDD Power Connec...

Страница 12: ...onfiguration Serial Port 2 Configuration 53 3 4 5 3 SIO Configuration Parallel Port Configuration 54 3 4 6 Advanced Hardware Monitor 55 3 4 6 1 Hardware Monitor Smart Fan Function Full on Mode 56 3 4...

Страница 13: ...Event Logs 77 3 9 1 Event Logs Change Smbios Event Log Settings 78 3 9 2 Event Logs View Smbios Event Log 80 Chapter 4 Drivers Installation 81 4 1 Drivers Installation 82 Appendix A Watchdog Timer Pro...

Страница 14: ...Network Appliance FWS 7820 Chapter 1 Chapter 1 Product Specifications...

Страница 15: ...lash x 1 Note 1 Expansion Interface PCIe x4 slot with x8 connector x 1 Note 2 USB 3 0 x2 Watchdog Timer 1 255 steps by software programming RTC Internal RTC Storage 3 5 SATA HDD bay x 1 or 2 5 SATA HD...

Страница 16: ...pset Intel integrated Connector VGA cable Optional I O Serial Port RJ 45 console x 1 Keyboard and Mouse USB USB 3 0 x 2 type A x 2 on I O side Reserved internal USB pin header GPIO 8 bit BIOS default...

Страница 17: ...eration 11m sec duration operation 20G peak acceleration 11m sec duration non operation Note 1 2nd SATA is Co layout with mSATA CF CFast The default is CF and you can choose any one from the 4 options...

Страница 18: ...Network Appliance FWS 7820 Chapter 2 Chapter 2 Hardware Information...

Страница 19: ...Network Appliance FWS 7820 2 1 Dimensions System Chapter 2 Hardware Information 6...

Страница 20: ...Network Appliance FWS 7820 Board Chapter 2 Hardware Information 7...

Страница 21: ...Network Appliance FWS 7820 Chapter 2 Hardware Information 8...

Страница 22: ...Network Appliance FWS 7820 PER T393 Chapter 2 Hardware Information 9...

Страница 23: ...Network Appliance FWS 7820 Chapter 2 Hardware Information 10...

Страница 24: ...Network Appliance FWS 7820 2 2 Jumpers and Connectors Component Side Chapter 2 Hardware Information 11...

Страница 25: ...Network Appliance FWS 7820 Solder Side Chapter 2 Hardware Information 12...

Страница 26: ...Network Appliance FWS 7820 PER T393 Chapter 2 Hardware Information 13...

Страница 27: ...Network Appliance FWS 7820 Chapter 2 Hardware Information 14...

Страница 28: ...rs Please refer to the table below for all of the board s jumpers that you can configure for your application Label Function CN40 RTC Reset CN39 Secondary RTC Reset CN23 CF Power Selection JP1 Auto Po...

Страница 29: ...3 2 Secondary RTC Reset CN39 Normal Default RTC TEST 2 3 3 Auto Power Button Selection CN23 Don t use Auto PWRBTN Default Use Auto PWRBTN 2 3 4 CFD Voltage 3 3 5V Selection JP1 3 3 V Default 5 V 1 2 3...

Страница 30: ...ector CPU_FAN1 CPU_FAN1 CPU_FAN2 CPU_FAN2 SYS_FAN1 SYS_FAN1 CN11 Power button CN12 PCIE Slot For FWS 7820 Pin Define CN14 COM Port CN17 LCM Connector CN18 CN27 SATA Port Connector CN19 CN20 HDD Power...

Страница 31: ...DIMM3 Channel B DDR4 U DIMM DIMM4 Channel B DDR4 U DIMM FP1 Front Panel Pin Header FP2 Front Panel Pin Header PCIE1 NIM Card Connector PCIE2 NIM Card Connector PCIE4 NIM Card Connector USB1 USB2 USB3...

Страница 32: ...Output 5 DIO4 Input Output 6 DIO5 Input Output 7 DIO6 Input Output 8 DIO7 Input Output 9 3 3V PWR 10 GND GND 2 4 2 LCM Connector 1 0mm FPC 1 x 16P CN17 Pin Signal Signal Type 1 LCMGND GND 2 LCMVCC PWR...

Страница 33: ...D Connector 2 54mm Pin Header 1 x 4P CN41 Pin Signal Signal Type 1 KEY PAD Down Input 2 KEY PAD Up Input 3 KEY PAD Right Input 4 KEY PAD Left Input 2 4 4 COM Port 2 0mm BOX Header 2 x 5P CN14 RS232 Pi...

Страница 34: ..._CRT PWR 3 Green Output 4 GND GND 5 Blue Output 6 CRT_PLUG Input 7 NC 8 DDC_DATA Input Output 9 GND GND 10 CRT_OHSYNCF Output 11 GND GND 12 CRT_OVSYNCF Output 13 GND GND 14 DDC_CLK Input Output 15 GND...

Страница 35: ...1 5V_USB PWR 2 USB3_RX1_DN DIFF 3 USB3_RX1_DP DIFF 4 GND GND 5 USB3_TX1_DN DIFF 6 USB3_TX1_DP DIFF 7 GND GND 8 USBP_0N DIFF 9 USBP_0P DIFF 10 NC 11 USBP_1P DIFF 12 USBP_1N DIFF 13 GND GND 14 USB3_TX2_...

Страница 36: ...3 GND GND 4 5V_KB PWR 5 MS_DATA Input Output 6 MS_CLK Output 7 NC 8 Key 2 4 9 Front Panel Pin Header FP1 Pin Signal Signal Type 1 External Speaker Output 2 Key Board Lock Output 3 NC Floting 4 GND POW...

Страница 37: ...5 HDD LED POWER 6 Power LED POWER 7 HDD LED Output 8 Power LED Output 2 4 11 LPC Connector 1 0mm Box Wafer 1 x 12P CN22 Pin Signal Signal Type 1 LAD0 Input Output 2 LAD1 Input Output 3 LAD2 Input Outp...

Страница 38: ...nel Jumpers and Connectors List Label Function SW1 Software Reset LED1 POWER STATE HDD LED Instruction CN4 COMSOLE 2PORT USB3 0 CN5 2PORT RJ45 Management LAN PORT CN6 4PORT RJ45 LAN PORT LED2 BYPASS L...

Страница 39: ...Network Appliance FWS 7820 2 6 Installing 2 5 Hard Disk Drives 2 pieces 1 Remove the highlighted screws 2 From the front of the system slide it upwards to remove Chapter 2 Hardware Information 26...

Страница 40: ...Network Appliance FWS 7820 3 Remove the four highlighted screws to remove the HDD bracket 4 Put the provided screws not the ones from step 3 into cushions Chapter 2 Hardware Information 27...

Страница 41: ...twork Appliance FWS 7820 5 Attach the assembled screws to the top and bottom of the inside of the bracket 6 Place the HDDs into the bracket tighten the screws to secure Chapter 2 Hardware Information...

Страница 42: ...Network Appliance FWS 7820 7 Place the assembled HDDs back into the system secure with screws and reattach the SATA and power cables Chapter 2 Hardware Information 29...

Страница 43: ...Network Appliance FWS 7820 Chapter 2 Hardware Information 30...

Страница 44: ...Network Appliance FWS 7820 2 7 Installing 3 5 Hard Disk 1 Remove the highlighted screws 2 From the front of the system slide it upwards to remove Chapter 2 Hardware Information 31...

Страница 45: ...Network Appliance FWS 7820 3 Remove the screws to remove the bracket 4 Place the 3 5 HDD on the bracket secure with screws on the underside Chapter 2 Hardware Information 32...

Страница 46: ...Network Appliance FWS 7820 5 Put the assembled HDD on the HDD bay secure with screws and reattach the SATA and power cables Chapter 2 Hardware Information 33...

Страница 47: ...Network Appliance FWS 7820 2 8 Installing CPU and Heat Sink 1 Remove the highlighted screws to remove the fan duct Chapter 2 Hardware Information 34...

Страница 48: ...Network Appliance FWS 7820 2 Lift the socket arm up to open the CPU socket Chapter 2 Hardware Information 35...

Страница 49: ...Network Appliance FWS 7820 Chapter 2 Hardware Information 36...

Страница 50: ...Network Appliance FWS 7820 3 Remove the cover and place the CPU into the socket Make sure the two fillisters are properly locked Chapter 2 Hardware Information 37...

Страница 51: ...rk Appliance FWS 7820 4 Push the arm down to lock the CPU into place 5 Place the heat sink onto the CPU Make sure the direction of the heat sink is not against the airflow Chapter 2 Hardware Informati...

Страница 52: ...Network Appliance FWS 7820 6 Close the air duct and secure with screws Chapter 2 Hardware Information 39...

Страница 53: ...Network Appliance FWS 7820 2 9 Installing Expansion Card 1 Remove the highlighted screws 2 From the front of the system slide it upwards to remove Chapter 2 Hardware Information 40...

Страница 54: ...Network Appliance FWS 7820 3 Remove the screw to remove the cover bracket 4 Firmly insert the expansion card into the slot and secure the screw Chapter 2 Hardware Information 41...

Страница 55: ...Network Appliance FWS 7820 Chapter 3 Chapter 3 AMI BIOS Setup...

Страница 56: ...guration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to set the configuration informa...

Страница 57: ...BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date element...

Страница 58: ...Network Appliance FWS 7820 3 3 Setup Submenu Main Chapter 3 AMI BIOS Setup 45...

Страница 59: ...Network Appliance FWS 7820 3 4 Setup Submenu Advanced Chapter 3 AMI BIOS Setup 46...

Страница 60: ...el Virtualization Technology Disabled Enabled Default En Disable CPU Virtualization Technology function Intel R SpeedStep tm Disabled Default Enabled When enabled OS sets CPU frequency according load...

Страница 61: ...es BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available TPM State Disable Enable Default Enable or Disables security device Pen...

Страница 62: ...ierarchy Storage Hierarchy Disable Enable Default Enable or Disables Storage Hierarchy 3 4 3 Advanced SATA Configuration Options summary SATA Controllers Disabled Enabled Default En Disable SATA Contr...

Страница 63: ...t Disabled Enabled Default En Disable Port Hot Plug Disabled Default Enabled En Disable Hot Plug function 3 4 4 Advanced PCH FW Configuration Options summary Firmware Update Configuration Disabled Def...

Страница 64: ...Network Appliance FWS 7820 3 4 5 Advanced SIO Configuration Chapter 3 AMI BIOS Setup 51...

Страница 65: ...y Use This Device Disabled Enabled Default Enable or Disable this Logical Device Possible Change Settings Auto Default IO 3F8h IRQ 4 IO 2F8h IRQ 3 Allows user to change Device s Resource settings New...

Страница 66: ...y Use This Device Disabled Enabled Default Enable or Disable this Logical Device Possible Change Settings Auto Default IO 2F8h IRQ 3 IO 3F8h IRQ 4 Allows user to change Device s Resource settings New...

Страница 67: ...efault Enable or Disable this Logical Device Possible Parallel Port Auto Default IO 378h IRQ 5 Allows user to change Device s Resource settings New settings will be reflected on This Setup Page after...

Страница 68: ...sabled Enabled Default Allows BIOS to En Disable CPU Fan 1 Smart Control CPU Fan 2 Smart Control Disabled Enabled Default Allows BIOS to En Disable CPU Fan 2 Smart Control SYS Fan 1 Smart Control Disa...

Страница 69: ...r Smart Fan Function Full on Mode Options summary Smart Fan Mode Full on Mode Automatic Mode Default Manual Mode Full on Mode Always on Manual Mode Depends on PWM Duty Automatic Mode FAN Speed is depe...

Страница 70: ...ons summary Smart Fan Mode Full on Mode Default Automatic Mode Manual Mode Full on Mode Always on Manual Mode Depends on PWM Duty Automatic Mode FAN Speed is depends on CPU Temperature Manual PWM Sett...

Страница 71: ...art Fan Mode Select Temperature Source CPU temperature Default System temperature Select temperature Source Fan off temperature limit 0 127 Default 15 Temperature Limit Value of Fan Off Note Some fans...

Страница 72: ...an start PWM 0 255 Default 35 Fan will start with this PWM value PWM SLOPE SETTING 0 15 Default 8 PWM SLOPE Selection Full Speed Temperature 0 127 Default 72 Temperature Limit Value of FAN Full Speed...

Страница 73: ...ns summary Legacy USB Support Enabled Default Disabled Auto Enables BIOS Support for Legacy USB Support When enabled USB can be functional in legacy environment like DOS AUTO option disables legacy su...

Страница 74: ...t Allows BIOS to select input output function to corresponding DIO ping DIO_P 5 8 Input Default Output Allows BIOS to select input output function to corresponding DIO ping DIO_P 1 4 Direction Low Hi...

Страница 75: ...er Management Options summary Power Mode ATX Type Default AT Type Select system power mode Restore AC Power Loss Last State Default Always on Always off RTC wake system from S5 Disabled Default Fixed...

Страница 76: ...n sec specified n Dynamic Time System will wake on the current time Increase minute s 3 4 10 Advanced LAN Bypass Configuration Options summary LAN Bypass Status LED Configuration LED OFF Default RED L...

Страница 77: ...N Bypass Status LED Configuration LAN Bypass Kit Configuration Mode for power on PassTru Default Bypass Mode for power off PassTru Default Bypass Select LAN Bypass Kit Configuration WDT Configuration...

Страница 78: ...isabled Console Redirection Enable or Disable Legacy Console Redirection Com0 Default Select Legacy Console Redirection port Console Redirection EMS Enabled Default Disabled Microsoft Windows Emergenc...

Страница 79: ...820 3 4 11 1 Serial Port Console Redirection COM0 Console Redirection Settings Options summary Terminal Type VT100 VT100 Default VT UTF8 ANSI Bits per second 9600 19200 38400 Default 57600 115200 Chap...

Страница 80: ...pace Stop Bits 1 Default 2 Flow Control None Default Hardware RTS CTS VT UTF8 Combo Key Support Enabled Default Disabled Recorder Mode Enabled Disabled Default Resolution 100x31 Enabled Disabled Defau...

Страница 81: ...S 7820 Putty Keypad VT100 Default LINUX XTERMR6 SCO ESCN VT400 Redirection After BIOS POST Always Enabe Default BootLoader 3 4 11 2 Serial Port Console Redirection Console Redirection Settings Chapter...

Страница 82: ...s Summary Out of Band Mgmt Port COM0 Default COM1 Terminal Type VT100 VT100 Default VT UTF8 ANSI Bits per second 9600 19200 Default 57600 115200 Flow Control None Default Hardware RTS CTS Software Xon...

Страница 83: ...Network Appliance FWS 7820 3 5 Setup submenu Chipset Chapter 3 AMI BIOS Setup 70...

Страница 84: ...Network Appliance FWS 7820 3 5 1 Chipset System Agent SA Configuration Options summary PEG Port Gen Speed Auto Default Gen1 Gen2 Gen3 Configure PEG Port Gen Speed Chapter 3 AMI BIOS Setup 71...

Страница 85: ...phics device should be Primary Display Or select SG for Switchable Gfx Primary IGFX Boot Display VBIOS Default Default CRT Select the Video Device which will be activated during POST This has no effec...

Страница 86: ...Network Appliance FWS 7820 3 5 2 Chipset PCH IO Configuration Options summary PCIEX4_1 Gen Speed Auto Default Gen1 Gen2 Gen3 Select PCI Express port speed Chapter 3 AMI BIOS Setup 73...

Страница 87: ...e features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or numbers Press Enter to confirm you...

Страница 88: ...ce FWS 7820 3 7 Setup submenu Boot Options summary Quiet Boot Disabled Default Enabled En Disable showing boot logo Launch PXE OpROM Disabled Default Enabled En Disable Legacy Boot Option Chapter 3 AM...

Страница 89: ...Network Appliance FWS 7820 3 8 Setup submenu Save Exit Chapter 3 AMI BIOS Setup 76...

Страница 90: ...Network Appliance FWS 7820 3 9 Setup submenu Event Logs Chapter 3 AMI BIOS Setup 77...

Страница 91: ...disable all features of Smbios Event Logging during boot Erase Event Log No Default Yes Next reset Yes Every reset Choose options for erasing Smbios Event Log Erasing is done prior to any logging act...

Страница 92: ...from 1 to 255 METW 0 99 Default 60 Mutiple Event Time Window The number of minutes which must pass between duplicate log entries which utilize a multiple event counter The value ranges from 0 to 99 m...

Страница 93: ...Network Appliance FWS 7820 3 9 2 Event Logs View Smbios Event Log Chapter 3 AMI BIOS Setup 80...

Страница 94: ...Network Appliance FWS 7820 Chapter 4 Chapter 4 Drivers Installation...

Страница 95: ...2 Install Graphic Driver 1 Open the Step 2 Graphic folder and select your OS 2 Open the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 3 Install...

Страница 96: ...followed by the SetupRST exe file 2 Follow the instructions 3 Drivers will be installed automatically Step 7 Install Serial Port Driver Optional Note Patch file for Serial port when encountering time...

Страница 97: ...FWS 7820 For Windows 7 32 64 bit 1 To run Change User Account Control Settings in Control panel User Accounts and Family Safety 2 Change User Account Control Settings to Never notify Chapter 4 Driver...

Страница 98: ...Network Appliance FWS 7820 3 Reboot 4 To run patch bat with Run as administrator Chapter 4 Driver Installation 85...

Страница 99: ...Network Appliance FWS 7820 For Windows 8 32 64 bit 1 Right click Command Prompt and run as administrator Chapter 4 Driver Installation 86...

Страница 100: ...Network Appliance FWS 7820 2 Run Command Prompt by administrator 3 To run patch bat in UART driver folder path Chapter 4 Driver Installation 87...

Страница 101: ...Network Appliance FWS 7820 4 Update successful 5 Restart Chapter 4 Driver Installation 88...

Страница 102: ...Network Appliance FWS 7820 6 Com port driver serial sys provider will change to Windows R Win7 DDK provider Chapter 4 Driver Installation 89...

Страница 103: ...Network Appliance FWS 7820 Appendix A Appendix A Watchdog Timer Programming...

Страница 104: ...Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This register is byte access Counting Unit 0x07 Note5 0x72 Note...

Страница 105: ...define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This parameter is represented from Note7 define byte Unit...

Страница 106: ...re AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure will enable the WDT counting AaeonWDTEna...

Страница 107: ...t Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet LDN Register BitNum Value VOID WDTParame...

Страница 108: ...te SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID SIOExitMBPnPMode IOWriteByte SIOIndex 0x02 IOWriteBy...

Страница 109: ...IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet byte LDN byte Register byte Value SIOEnt...

Страница 110: ...Network Appliance FWS 7820 Appendix B Appendix B I O Information...

Страница 111: ...Network Appliance FWS 7820 B 1 I O Address Map Appendix B I O Information 98...

Страница 112: ...Network Appliance FWS 7820 Appendix B I O Information 99...

Страница 113: ...Network Appliance FWS 7820 B 2 Memory Address Map Appendix B I O Information 100...

Страница 114: ...Network Appliance FWS 7820 Appendix B I O Information 101...

Страница 115: ...Network Appliance FWS 7820 B 3 IRQ Mapping Chart Appendix B I O Information 102...

Страница 116: ...Network Appliance FWS 7820 Appendix B I O Information 103...

Страница 117: ...Network Appliance FWS 7820 Appendix B I O Information 104...

Страница 118: ...Network Appliance FWS 7820 Appendix B I O Information 105...

Страница 119: ...Network Appliance FWS 7820 Appendix B I O Information 106...

Страница 120: ...Network Appliance FWS 7820 Appendix B I O Information 107...

Страница 121: ...Network Appliance FWS 7820 Appendix B I O Information 108...

Страница 122: ...Network Appliance FWS 7820 Appendix B I O Information 109...

Страница 123: ...Network Appliance FWS 7820 Appendix B I O Information 110...

Страница 124: ...Network Appliance FWS 7820 Appendix B I O Information 111...

Страница 125: ...Network Appliance FWS 7820 Appendix B I O Information 112...

Страница 126: ...Network Appliance FWS 7820 Appendix B I O Information 113...

Страница 127: ...Network Appliance FWS 7820 Appendix B I O Information 114...

Страница 128: ...Network Appliance FWS 7820 Appendix C Appendix C Standard LAN Bypass Platform Setting...

Страница 129: ...nk 0 1 1 Reserved 1 0 0 Green LED Blink 1 0 1 Green LED Fast Blink 1 1 0 Green LED On 1 1 1 Table2 Status LED and register mapping table CPLD Slave Address 0x90 Note1 Attribute Offset SMBUS BitNum Val...

Страница 130: ...SLAVE_ADDRESS OFFSET switch LED_FLAG case 0 LED Off BIT2 0 BIT1 0 BIT0 0 bData bData 0xF8 break case 1 Red LED On BIT2 0 BIT1 0 BIT0 1 bData bData 0xF8 0x01 break case 2 Red LED Blink BIT2 0 BIT1 1 BI...

Страница 131: ...ase 5 Green LED Blink BIT2 1 BIT1 0 BIT0 1 bData bData 0xF8 0x05 break case 6 Green LED Fast Blink BIT2 1 BIT1 1 BIT0 0 bData bData 0xF8 0x06 break default break SmbusWriteByte CPLD_SLAVE_ADDRESS 0x00...

Страница 132: ...0 0 1 LAN Kit 10 Selected Table2 LAN Bypass register table Function Description LAN_ID3 Use for selecting which LAN kit will be configured refert to Table 1 of ID Select table of LAN kit They should...

Страница 133: ...0x01 Note2 2 Table 1 LAN_ID1 R W 0x01 Note2 1 Table 1 LAN_ID0 R W 0x01 Note2 0 Table 1 PWR_ON R W 0x01 Note2 6 Table 2 PWR_OFF R W 0x01 Note2 5 Table 2 WDT_EN R W 0x01 Note2 4 Table 2 ACT_EN R W 0x01...

Страница 134: ...ff Action Reg01h bit5 if SET_PASS_THROUGH Pass Through bData bData 0xDF else Bypass bData bData 0x20 WDT Action Reg01h bit4 if SET_WDT_RESET Reset bData bData 0xEF else Bypass bData bData 0x10 SmbusWr...

Страница 135: ...er returns the pin level status which is normal high active low 0 Pin Level States Low 1 Pin Level States High Sample Code define Word BTN_STS This parameter is represented from Note1 define Byte BTN_...

Отзывы: