background image

 

 

Chapter 3 – AMI BIOS Setup 

 

83

 

Fan

les

s E

mb
ed

ded

 Bo

PC

 

 

 

AE

C-

6637

 

 

1 GB 

 

1.25 GB 

 

1.5 GB 

 

1.75 GB 

 

2 GB 

 

2.25 GB 

 

2.5 GB 

 

2.75 GB 

3 GB 

3.25 GB 

Maximum Value of TOLUD. Dynamic assignment would adjust TOLUD automatically 

based on largest MMIO length of install graphic controller. 

 

 

Содержание AEC-6637

Страница 1: ...Last Updated December 31 2015 AEC 6637 Fanless Embedded Box PC User s Manual 3rd Ed ...

Страница 2: ...ed in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to as...

Страница 3: ...d trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Страница 4: ...ing items have been shipped Item Quantity BOXER 6637 1 RAM thermal pad 1998F15003 x 1 1998666630 x2 1998666652 x 1 4 Screw package 1 Wallmount bracket 2 Product DVD with User s Manual in pdf and drivers 1 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Страница 5: ...s detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the AAEON com for the latest version of this document ...

Страница 6: ...he system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disconnect it from the power supply to avoid damage by transient over voltage 8 Always disconnect this device from any AC supply before cleaning 9 While cleaning use a damp cloth instead of liquid or s...

Страница 7: ...ners 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 19 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENVI...

Страница 8: ...xplosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalent r...

Страница 9: ...ed Box PC Industrial System 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 电源 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 电源为选购品 ...

Страница 10: ...l Ethers PBDE PCB Other Components Wires Connectors for External Connections Chassis CPU RAM Hard Disk PSU O The quantity of poisonous or hazardous substances or elements found in each of the component s parts is below the SJ T 11363 2006 stipulated requirement X The quantity of poisonous or hazardous substances or elements found in at least one of the component s parts is beyond the SJ T 11363 20...

Страница 11: ... 3 4 COM2 Pin8 Function Selection JP8 13 2 3 5 Front Panel Connector JP9 14 2 3 6 Touch Screen 4 5 8 Wire Selection JP10 14 2 3 7 Clear CMOS JP11 14 2 3 8 AT ATX Power Supply Mode Selection JP12 15 2 4 List of Connectors 16 2 4 1 LVDS Port 1 Inverter Backlight Connector CN1 18 2 4 2 External 12V Input CN2 18 2 4 3 USB2 0 Port 7 and Port 8 CN3 19 2 4 4 USB2 0 Port 5 and Port 6 CN4 19 2 4 5 USB2 0 P...

Страница 12: ...0 Realtek LAN RJ 45 Port CN23 34 2 4 21 Intel LAN RJ 45 Port CN24 35 2 4 22 USB Port 1 and Port 2 CN25 35 2 4 23 VGA Port CN26 36 2 4 24 COM Port 1 D SUB 9 CN27 37 2 4 25 CFast Slot CN28 37 2 4 26 DDR3 SODIMM Slot CN29 38 2 4 27 Mini Card Slot CN30 38 2 4 28 SATA Port 1 SATA1 40 2 4 29 SATA Port 2 SATA2 41 2 5 CFast Card Installation 42 2 6 Hard Disk Drive HDD Installation 45 2 7 Memory Card Insta...

Страница 13: ...er IO Configuration Serial Port 2 Configuration 74 3 4 7 3 Super IO Configuration Serial Port 3 Configuration 76 3 4 7 4 Super IO Configuration Serial Port 4 Configuration 77 3 5 Setup submenu Chipset 78 3 5 1 Chipset Onboard Device 79 3 5 2 Chipset PCH IO Configuration 80 3 5 3 Chipset Memory Configuration 82 3 5 4 Chipset Graphic Configuration 84 3 6 Setup submenu Boot 86 3 6 1 Boot BBS Prioriti...

Страница 14: ...nless Embedded Box PC AEC 6637 B 1 I O Address Map 106 B 2 Memory Address Map 108 B 3 IRQ Mapping Chart 109 B 4 DMA Channel Assignments 110 Appendix C RAID AHCI Settings 111 C 1 Setting RAID 112 C 2 Setting AHCI 119 ...

Страница 15: ...Fanless Embedded Box PC AEC 6637 Chapter 1 Chapter 1 Product Specifications ...

Страница 16: ...B Chipset Intel QM77 Display Interface VGA DB 15 x 1 Storage Device SSD Onboard CFast x 1 HDD 2 5 SATA 6 0Gb s Hard Disk Drive Bay x 1 Network LAN Gigabit Ethernet Wireless Optional by Mini Card Front I O USB Host USB 2 0 x 2 LAN Serial Port DIO Audio 1 KB MS Others Power ON OFF Switch x 1 antenna hole x 2 Rear I O USB Host USB 3 0 x 1 LAN RJ 45 x 2 Serial Port RS 232 x 3 RS 232 422 485 x 1 DIO Au...

Страница 17: ...ting Wall mounted Dimension W x H x D 212 x 64 x 156 mm 8 36 x 2 52 x 6 2 Gross Weight 3 6 kg 7 94 lb Certification EMC CE FCC Class A Safety OS Support Windows 10 Windows 7 Windows XP Windows XP Embedded Ubuntu 11 10 Kernel 3 0 0 12 generic Environmental Operating Temperature 10 45 C 14 113 F CFast without air flow 10 50 C 14 122 F HDD without air flow Storage Temperature 20 70 C 4 158 F Anti Vib...

Страница 18: ...Chapter 1 Product Specifications 4 Fanless Embedded Box PC AEC 6637 Anti Shock 50G peak acceleration 11 msec duration CFast 20G peak acceleration 11 msec duration HDD ...

Страница 19: ...Fanless Embedded Box PC AEC 6637 Chapter 2 Chapter 2 Hardware Information ...

Страница 20: ...Chapter 2 Hardware Information 6 Fanless Embedded Box PC AEC 6637 2 1 Dimensions A1M A2M Version ...

Страница 21: ...Chapter 2 Hardware Information 7 Fanless Embedded Box PC AEC 6637 ...

Страница 22: ...Chapter 2 Hardware Information 8 Fanless Embedded Box PC AEC 6637 C1 C2 Version ...

Страница 23: ...Chapter 2 Hardware Information 9 Fanless Embedded Box PC AEC 6637 ...

Страница 24: ...Chapter 2 Hardware Information 10 Fanless Embedded Box PC AEC 6637 2 2 Jumpers and Connectors Component Side Component Side ...

Страница 25: ...Chapter 2 Hardware Information 11 Fanless Embedded Box PC AEC 6637 Solder Side Solder Side ...

Страница 26: ...an configure for your application Label Function JP3 LVDS Port 1 Backlight Inverter VCC Selection JP5 LVDS Port 1 Operating VDD Selection JP6 LVDS Port 1 Backlight Lightness Control Mode Selection JP8 COM2 Pin8 Function Selection JP9 Front Panel Connector JP10 Touch Screen 4 5 8 wire Mode Selection JP11 Clear CMOS Jumper JP12 AT ATX Power Supply Mode Selection ...

Страница 27: ...unction Selection JP8 12V Ring Default 5V 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 ...

Страница 28: ...onnector JP9 Pin Signal 1 PWR_BTN 2 PWR_BTN 3 HDD_LED 4 HDD_LED 5 SPEAKER 6 SPEAKER 7 PWR_LED 8 PWR_LED 9 H W RESET 2 3 6 Touch Screen 4 5 8 Wire Selection JP10 4 8 wire Mode Default 5 wire Mode 2 3 7 Clear CMOS JP11 Normal Default Clear CMOS 1 2 3 4 5 6 7 8 9 10 1 2 3 1 2 3 1 2 3 1 2 3 ...

Страница 29: ...Chapter 2 Hardware Information 15 Fanless Embedded Box PC AEC 6637 2 3 8 AT ATX Power Supply Mode Selection JP12 AT Mode Default ATX Mode 1 2 3 1 2 3 ...

Страница 30: ...12V Input CN3 USB 2 0 Ports 7 and 8 CN4 USB 2 0 Ports 5 and 6 CN5 USB 2 0 Ports 3 and 4 CN6 External 5VSB Input CN8 Audio I O Port CN9 LVDS Port 1 CN11 COM Port 2 CN12 LPT Digital I O Port CN13 COM Port 3 CN14 LPC Port CN15 COM Port 4 CN16 UIM Card Module CN17 PS 2 Keyboard Mouse Combo Port CN18 5VSB Output w SMBus CN19 Touch Screen Connector CN20 CPU FAN CN22 5V Output for SATA HDD CN23 Realtek L...

Страница 31: ...hapter 2 Hardware Information 17 Fanless Embedded Box PC AEC 6637 CN27 COM Port 1 D SUB 9 CN28 CFast Slot CN29 DDR3 SODIMM Slot CN30 Mini Card Slot SATA1 SATA Port1 Connector SATA2 SATA Port 2 Connector ...

Страница 32: ...gnal Type Signal level 1 BKL_PWR PWR 5V 12V 2 BKL_CONTROL OUT 3 GND GND 4 GND GND 5 BKL_ENABLE OUT 5V Note LVDS1 BKL_PWR can be set to 5V or 12V by JP3 LVDS1 BKL_CONTROL can be set by JP6 2 4 2 External 12V Input CN2 Pin Pin Name Signal Type Signal level 1 12V PWR 12V 2 GND GND BLK_PWR 2 3 4 5 1 BKL_CONTROL GND GND BKL_ENABLE 12V GND ...

Страница 33: ...D 3 USB7_D DIFF 4 GND GND 5 USB7_D DIFF 6 USB8_D DIFF 7 GND GND 8 USB8_D DIFF 9 GND GND 10 5VSB PWR 5V 2 4 4 USB2 0 Port 5 and Port 6 CN4 Pin Pin Name Signal Type Signal level 1 5VSB PWR 5V 2 GND GND 3 USB5_D DIFF 4 GND GND 5 USB5_D DIFF GND GND USB8_D USB8_D 5VSB 5VSB 1 2 9 10 USB7_D USB7_D GND GND GND GND USB6_D USB6_D 5VSB 5VSB 1 2 9 10 USB5_D USB5_D GND GND ...

Страница 34: ...SB PWR 5V 2 4 5 USB2 0 Port 3 and Port 4 CN5 Pin Pin Name Signal Type Signal level 1 5VSB PWR 5V 2 GND GND 3 USB3_D DIFF 4 GND GND 5 USB3_D DIFF 6 USB4_D DIFF 7 GND GND 8 USB4_D DIFF 9 GND GND 10 5VSB PWR 5V 2 4 6 External 5VSB Input CN6 GND GND USB4_D USB4_D 5VSB 5VSB 1 2 9 10 USB3_D USB3_D GND GND 5VSB GND PS_ON 1 2 3 ...

Страница 35: ... 3 5VSB PWR 5V 2 4 7 Audio I O Port Connector CN8 Pin Pin Name Signal Type Signal level 1 MIC_L IN 2 MIC_R IN 3 GND_AUDIO GND 4 LINE_L_IN IN 5 LINE_R_IN IN 6 GND_AUDIO GND 7 LEFT_OUT OUT 8 GND_AUDIO GND 9 RIGHT_OUT OUT 10 5V_AUDIO PWR 5V MIC_L 1 10 MIC_R LINE_L_IN LINE_R_IN LEFT_OUT RIGHT_OUT 5V_AUDIO GND_AUDIO GND_AUDIO GND_AUDIO ...

Страница 36: ...L_ENABLE OUT 2 BKL_CONTROL OUT 3 LCD_PWR PWR 3 3V 5V 4 GND GND 5 LVDS_A_CLK DIFF 6 LVDS_A_CLK DIFF 7 LCD_PWR PWR 3 3V 5V 8 GND GND 9 LVDS_DA0 DIFF 10 LVDS_DA0 DIFF 11 LVDS_DA1 DIFF 12 LVDS_DA1 DIFF 13 LVDS_DA2 DIFF 14 LVDS_DA2 DIFF 15 LVDS_DA3 DIFF 16 LVDS_DA3 DIFF 17 DDC_DATA I O 3 3V 18 DDC_CLK I O 3 3V PIN 1 PIN 2 PIN 30 PIN 29 ...

Страница 37: ...23 LVDS_DB2 DIFF 24 LVDS_DB2 DIFF 25 LVDS_DB3 DIFF 26 LVDS_DB3 DIFF 27 LCD_PWR PWR 3 3V 5V 28 GND GND 29 LVDS_B_CLK DIFF 30 LVDS_B_CLK DIFF Note LVDS1 LCD_PWR can be set to 3 3V or 5V by JP5 2 4 9 COM Port 2 Connector CN11 RS 232 Pin Pin Name Signal Type Signal level 1 DCD IN 2 DSR IN 3 RX IN 4 RTS OUT 9V 5 TX OUT 9V 1 2 3 4 5 6 7 8 9 ...

Страница 38: ...5V 12V 9 GND GND RS 422 Pin Pin Name Signal Type Signal level 1 RS422_TX OUT 5V 2 NC 3 RS422_RX IN 4 NC 5 RS422_TX OUT 5V 6 NC 7 RS422_RX IN 8 NC 5V 12V PWR 5V 12V 9 GND GND RS 485 Pin Pin Name Signal Type Signal level 1 RS485_D I O 5V 2 NC 3 NC 4 NC 5 RS485_D I O 5V 6 NC 7 NC 8 NC 5V 12V PWR 5V 12V 9 GND GND ...

Страница 39: ... Type Signal level 1 STROBE IN 2 AFD I O 3 PD0 I O 4 ERROR IN 5 PD1 I O 6 PRINT I O 7 PD2 I O 8 SLIN I O 9 PD3 I O 10 GND GND 11 PD4 I O 12 GND GND 13 PD5 I O 14 GND GND 15 PD6 I O N C N C N C N C N C GND GND GND GND GND GND GND GND N C DIO0 DIO1 DIO2 DIO3 N C N C N C N C DIO7 DIO6 DIO5 DIO4 STROBE 1 2 25 26 1 2 25 26 AFD ERROR PRINT SLIN GND GND GND GND GND GND GND GND N C PD0 PD1 PD2 PD3 PD4 PD5...

Страница 40: ... set by BIOS setting Default is LPT Function DIO Mode Pin Pin Name Signal Type Signal level 1 NC 2 NC 3 DIO0 I O 5V 4 NC 5 DIO1 I O 5V 6 NC 7 DIO2 I O 5V N C N C N C N C N C GND GND GND GND GND GND GND GND N C DIO0 DIO1 DIO2 DIO3 N C N C N C N C DIO7 DIO6 DIO5 DIO4 STROBE 1 2 25 26 1 2 25 26 AFD ERROR PRINT SLIN GND GND GND GND GND GND GND GND N C D0 D1 D2 D3 D4 D5 D6 D7 ACK BUSY PE SLCT LPT Mode ...

Страница 41: ...5V 20 GND GND 21 DIO6 I O 5V 22 GND GND 23 DIO5 I O 5V 24 GND GND 25 DIO4 I O 5V 26 NC GPIO Port Pin Name Location Pin I O Port Access Address Port 1 DIO0 3 Bit 0 of 0xA06 Port 2 DIO1 5 Bit 1 of 0xA06 Port 3 DIO2 7 Bit 2 of 0xA06 Port 4 DIO3 9 Bit 3 of 0xA06 Port 5 DIO4 25 Bit 0 of 0xA07 Port 6 DIO5 23 Bit 1 of 0xA07 Port 7 DIO6 21 Bit 2 of 0xA07 Port 8 DIO7 19 Bit 3 of 0xA07 ...

Страница 42: ...Name Signal Type Signal level 1 DCD IN 2 DSR IN 3 RX IN 4 RTS OUT 9V 5 TX OUT 9V 6 CTS IN 7 DTR OUT 9V 8 RI IN 9 GND GND 2 4 12 LPC Port Connector CN14 Pin Pin Name Signal Type Signal level 1 LAD0 I O 3 3V DCD DSR RX RTS TX CTS DTR RI GND LAD0 1 12 LAD1 LAD2 LAD3 LFRAME LRESET LDRQ0 LDRQ1 SERIRQ GND LCLK 3 3V ...

Страница 43: ...3 I O 3 3V 5 3 3V PWR 3 3V 6 LFRAME IN 7 LRESET OUT 3 3V 8 GND GND 9 LCLK OUT 10 LDRQ0 IN 11 LDRQ1 IN 12 SERIRQ I O 3 3V 2 4 13 COM Port 4 Connector CN15 Pin Pin Name Signal Type Signal level 1 DCD IN 2 DSR IN 3 RX IN 4 RTS OUT 9V 5 TX OUT 9V 6 CTS IN 7 DTR OUT 9V 8 RI IN DCD DSR RX RTS TX CTS DTR RI GND ...

Страница 44: ..._PWR PWR 2 UIM_RST IN 3 UIM_CLK IN 4 GND GND 5 UIM_VPP PWR 6 UIM_DATA I O 2 4 15 PS 2 Keyboard Mouse Combo Port Connector CN17 Pin Pin Name Signal Type Signal level 1 KB_DATA I O 5V 2 KB_CLK I O 5V 3 GND GND 4 5VSB PWR 5V 5 MS_DATA I O 5V 6 MS_CLK I O 5V UIM_PWR 1 6 UIM_RST UIM_CLK GND UIM_VPP UIM_DATA KB_CLK KB_DATA 1 4 6 2 MS_DATA 5VSB GND MS_CLK ...

Страница 45: ..._ON OUT 3 3V 6 5VSB PWR 5V 2 4 17 Touch Screen Connector CN19 4 wire Pin Pin Name Signal Type Signal level 1 GND GND 2 TOP IN 3 BOTTOM IN 4 LEFT IN SMB_DATA 1 6 GND SMB_CLK GND PS_ON 5VSB GND 1 9 1 9 1 9 TOP EXCITE BOTTOM EXCITE LEFT EXCITE RIGHT EXCITE TOP SENSE BOTTOM SENSE LEFT SENSE RIGHT SENSE GND TOP BOTTOM LEFT RIGHT NC NC NC NC GND UL Y UR H LL L LR X SENSE S NC NC NC 8 Wires 4 Wires 5 Wir...

Страница 46: ...gnal Type Signal level 5 RIGHT IN 6 NC 7 NC 8 NC 9 NC 5 wire Pin Pin Name Signal Type Signal level 1 GND GND 2 UL Y IN 3 UR H IN 4 LL L IN 5 LR X IN 6 SENSE S IN 7 NC 8 NC 9 NC 1 9 1 9 1 9 GND TOP BOTTOM LEFT RIGHT NC NC NC NC GND UL Y UR H LL L LR X SENSE S NC NC NC 8 Wires 4 Wires 5 Wires ...

Страница 47: ...OTTOM SENSE IN 8 LEFT SENSE IN 9 RIGHT SENSE IN Note Touch mode can be set by JP10 2 4 18 CPU FAN Connector CN20 Pin Pin Name Signal Type Signal level 1 GND GND 2 FAN_POWER PWR 5V GND 1 9 1 9 TOP EXCITE BOTTOM EXCITE LEFT EXCITE RIGHT EXCITE TOP SENSE BOTTOM SENSE LEFT SENSE RIGHT SENSE GND TOP BOTTOM LEFT RIGHT NC NC NC NC GND UL Y UR H LL L LR X SENSE S NC NC NC 8 Wires 4 Wires 5 GND 1 2 3 FAN_P...

Страница 48: ...V Output for SATA HDD CN22 Pin Pin Name Signal Type Signal level 1 5V PWR 5V 2 GND GND 2 4 20 Realtek LAN RJ 45 Port CN23 Pin Pin Name Signal Type Signal level 1 MDI0 DIFF 2 MDI0 DIFF 3 MDI1 DIFF 4 MDI2 DIFF 5 MDI2 DIFF 6 MDI1 DIFF 7 MDI3 DIFF 8 MDI3 DIFF 5V GND 1 ACT LINK LED SPEED LED 8 ...

Страница 49: ...0 DIFF 2 MDI0 DIFF 3 MDI1 DIFF 4 MDI2 DIFF 5 MDI2 DIFF 6 MDI1 DIFF 7 MDI3 DIFF 8 MDI3 DIFF 2 4 22 USB Port 1 and Port 2 CN25 Pin Pin Name Signal Type Signal level 1 5VSB PWR 5V 2 USB1_D DIFF 3 USB1_D DIFF 4 GND GND 5 USB1_SSRX DIFF 6 USB1_SSRX DIFF 7 GND GND 1 ACT LINK LED SPEED LED 8 10 Port 2 Port 1 11 12 13 1 2 3 4 14 15 16 17 18 5 6 7 8 9 ...

Страница 50: ... 11 USB2_D DIFF 12 USB2_D DIFF 13 GND GND 14 USB2_SSRX DIFF 15 USB2_SSRX DIFF 16 GND GND 17 USB2_SSTX DIFF 18 USB2_SSTX DIFF 2 4 23 VGA Port CN26 Pin Pin Name Signal Type Signal level 1 RED OUT 2 GREEN OUT 3 BLUE OUT 4 NC 5 GND GND 6 RED_GND_RTN GND 7 GREEN_GND_RTN GND 8 BLUE_GND_RTN GND 9 5V PWR 5V 10 GND GND 11 NC ...

Страница 51: ...5 DDC_CLK I O 5V 2 4 24 COM Port 1 D SUB 9 CN27 Pin Pin Name Signal Type Signal level 1 DCD IN 2 RX IN 3 TX OUT 9V 4 DTR OUT 9V 5 GND GND 6 DSR IN 7 RTS OUT 9V 8 CTS IN 9 RI IN 2 4 25 CFast Slot CN28 Pin Pin Name Signal Type Signal level S1 GND GND S2 SATA_TX DIFF S3 SATA_TX DIFF S4 GND GND S5 SATA_RX DIFF 1 5 6 9 ...

Страница 52: ...GND GND PC3 NC PC4 NC PC5 NC PC6 NC PC7 GND GND PC8 NC PC9 NC PC10 NC PC11 NC PC12 NC PC13 3 3V PWR 3 3V PC14 3 3V PWR 3 3V PC15 GND GND PC16 GND GND PC17 NC 2 4 26 DDR3 SODIMM Slot CN29 Standard specification 2 4 27 Mini Card Slot CN30 Pin Pin Name Signal Type Signal level 1 PCIE_WAKE IN 2 3 3VSB PWR 3 3V ...

Страница 53: ... 9 GND GND 10 UIM_DATA I O 11 PCIE_REF_CLK DIFF 12 UIM_CLK IN 13 PCIE_REF_CLK DIFF 14 UIM_RST IN 15 GND GND 16 UIM_VPP PWR 17 NC 18 GND GND 19 NC 20 W_DISABLE OUT 3 3V 21 GND GND 22 PCIE_RST OUT 3 3V 23 PCIE_RX DIFF 24 3 3VSB PWR 3 3V 25 PCIE_RX DIFF 26 GND GND 27 GND GND 28 1 5V PWR 1 5V 29 GND GND 30 SMB_CLK I O 3 3V 31 PCIE_TX DIFF ...

Страница 54: ...IE_TX DIFF 34 GND GND 35 GND GND 36 USB_D DIFF 37 GND GND 38 USB_D DIFF 39 3 3VSB PWR 3 3V 40 GND GND 41 3 3VSB PWR 3 3V 42 NC 43 GND GND 44 NC 45 NC 46 NC 47 NC 48 1 5V PWR 1 5V 49 NC 50 GND GND 51 NC 52 3 3VSB PWR 3 3V 2 4 28 SATA Port 1 SATA1 Pin Pin Name Signal Type Signal level Pin 1 Pin 7 ...

Страница 55: ...C 6637 1 GND GND 2 SATA_TX DIFF 3 SATA_TX DIFF 4 GND GND 5 SATA_RX DIFF 6 SATA_RX DIFF 7 GND GND 2 4 29 SATA Port 2 SATA2 Pin Pin Name Signal Type Signal Level 1 GND GND 2 SATA_TX DIFF 3 SATA_TX DIFF 4 GND GND 5 SATA_RX DIFF 6 SATA_RX DIFF 7 GND GND Pin 1 Pin 7 ...

Страница 56: ...Chapter 2 Hardware Information 42 Fanless Embedded Box PC AEC 6637 2 5 CFast Card Installation Step 1 Remove the screws on the AEC 6637 Step 2 Remove the screws on the brackets ...

Страница 57: ...Chapter 2 Hardware Information 43 Fanless Embedded Box PC AEC 6637 Step 3 Remove the screws on the bottom cover Step 4 Remove the screws on the CFast bracket ...

Страница 58: ...Fanless Embedded Box PC AEC 6637 Step 5 Install the CFast Card to the CFast slot and adhere the thermal pad onto the CFast Card Then cover up the CFast Bracket Step 6 Tighten the screws on the CFast bracket to complete the installation ...

Страница 59: ...Chapter 2 Hardware Information 45 Fanless Embedded Box PC AEC 6637 2 6 Hard Disk Drive HDD Installation Step 1 Remove the screws on the AEC 6637 Step 2 Remove the screws oo the brackets ...

Страница 60: ...er 2 Hardware Information 46 Fanless Embedded Box PC AEC 6637 Step 3 Remove on the screws oo the bottom cover Step 4 Get the HDD and HDD Bracket ready Attach the HDD to the HDD bracket and tighten the screws ...

Страница 61: ...Chapter 2 Hardware Information 47 Fanless Embedded Box PC AEC 6637 Step 5 Connect the SATA cable to the HDD Step 6 Close the bottom cover of the AEC 6637 Tight the screws to secure ...

Страница 62: ...Chapter 2 Hardware Information 48 Fanless Embedded Box PC AEC 6637 2 7 Memory Card Installation Step 1 Remove the screws on the AEC 6637 Step 2 Remove the screws on the brackets ...

Страница 63: ...Chapter 2 Hardware Information 49 Fanless Embedded Box PC AEC 6637 Step 3 Remove the screws on the bottom cover Step 4 Remove the screws on the bracket of Memory Card ...

Страница 64: ...ed Box PC AEC 6637 Step 5 Adhere the Thermal pads onto the top and bottom of the Memory Card and then insert the RAM diagonally to the memory slot push down to secure Step 6 Tighten the screws of the bracket of Memory Card to finish the installation ...

Страница 65: ...Chapter 2 Hardware Information 51 Fanless Embedded Box PC AEC 6637 2 8 Wallmount Kit Installation To attach the wallmount kit on to the AEC 6637 tightens four screws as shown in the diagram below ...

Страница 66: ...Fanless Embedded Box PC AEC 6637 Chapter 3 Chapter 3 AMI BIOS Setup ...

Страница 67: ...s check the current system configuration against the values stored in the CMOS memory If they do not match an error message will be outputted in which case you will need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS settings You are starting your system for the first time You have changed your syste...

Страница 68: ... when the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date elements Advanced Enable Disable boot option for legacy network devices Chipset For hosting bridge parameters Boot Enable Disable quiet Boot Option Security The setup a...

Страница 69: ...nless Embedded Box PC AEC 6637 3 3 Setup Submenu Main Options summary default setting System Date Day MM DD YYYY Change the month year and century The Day is changed automatically System Time HH MM SS Change the clock of the system ...

Страница 70: ...ubmenu Advanced Options summary default setting ACPI Settings System ACPI Parameters CPU Configuration CPU Configuration Parameters SATA Configuration SATA Device Options Settings AMT Configuration AMT Configuration Parameters USB Configuration USB Configuration Parameters ...

Страница 71: ...Chapter 3 AMI BIOS Setup 57 Fanless Embedded Box PC AEC 6637 H W Monitor Monitor hardware status Super IO Configuration Super IO Configuration Parameters ...

Страница 72: ...ettings Options summary default setting Enable Hibernation Enabled Disabled Enabled or disabled hibernate OS S4 Sleep State ACPI Sleep State Suspend Disabled S1 only CPU Stop Clock S3 only Suspend to RAM Auto Select the ACPI state used for System Suspend Wake on Ring Enabled Disabled ...

Страница 73: ...Chapter 3 AMI BIOS Setup 59 Fanless Embedded Box PC AEC 6637 Enabled or disabled wake on ring function RTC Wake Settings Enable system to wake from S5 using RTC alarm ...

Страница 74: ...3 4 1 1 ACPI Settings RTC Wake Settings Options summary default setting Wake system with Fixed Time Disabled Enabled Enable or disable System wake on alarm event Wake up time is setting by following settings Wake up day 0 31 Wake up hour 0 23 Wake up minute 0 59 ...

Страница 75: ...up 61 Fanless Embedded Box PC AEC 6637 Wake up second 0 59 Wake system with Dynamic Time Disabled Enabled Enable or disable System wake on alarm event Wake up time is current time Increase minutes Wake up minute increase 1 5 ...

Страница 76: ...figuration Options summary default setting Hyper Threading Disabled Enabled En Disable CPU Hyper Threading function Active Processor Cores ALL 1 to Max CPU cores Number of CPU cores to be active Limit CPUID Maximum Disabled Enabled Disabled for Windows XP Execute Disable Bit Disabled ...

Страница 77: ...etup 63 Fanless Embedded Box PC AEC 6637 Enabled En Disable XD bit for supporting OS Intel Virtualization Technology Disabled Enabled En Disable Intel VT x function CPU PPM Configuration CPU Power Management configuration ...

Страница 78: ...iguration CPU PPM Configuration Options summary default setting EIST Enabled Disabled En Disable Intel SpeedStep Turbo Mode Disabled Enabled En Disable Intel Turbo Mode CPU C1 Enhanced Report Disabled Enabled Report CPU support ACPI C1 Enhanced state to OS CPU C3 Report Disabled ...

Страница 79: ...p 65 Fanless Embedded Box PC AEC 6637 Enabled Report CPU support ACPI C3 state to OS CPU C6 Report Disabled Enabled Report CPU support ACPI C6 state to OS CPU C7 Report Disabled Enabled Report CPU support ACPI C7 state to OS ...

Страница 80: ...iguration Options summary default setting SATA Controller s Disabled Enabled En Disable SATA controller Configure SATA as IDE AHCI RAID Available for QM77 Sku Configure SATA controller operating as IDE AHCI RAID mode Port 1 Port 2 CFast Slot Disabled Enabled En Disable the selected port ...

Страница 81: ...Chapter 3 AMI BIOS Setup 67 Fanless Embedded Box PC AEC 6637 Hot Plug Disabled Enabled En Disable Hot Plug feature for specified port ...

Страница 82: ...apter 3 AMI BIOS Setup 68 Fanless Embedded Box PC AEC 6637 3 4 4 Advanced AMT Configuration Options summary default setting Un Configure ME Enabled Disabled OEMFlag Bit 15 Un Configure ME without password ...

Страница 83: ...les BIOS Support for Legacy USB Support When enabled USB can be functional in legacy environment like DOS AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI application USB3 0 Support Enabled Disabled Enables BIOS Support for USB3 0 XHCI When disabled PCH USB3 0 controller will also be disabled ...

Страница 84: ...ce Name Emulation Type Auto Floppy Forced FDD Hard Disk CD ROM If Auto USB devices less than 530MB will be emulated as Floppy and remaining as Floppy and remaining as hard drive Forced FDD option can be used to force a HDD formatted drive to boot as FDD Ex ZIP drive ...

Страница 85: ...Chapter 3 AMI BIOS Setup 71 Fanless Embedded Box PC AEC 6637 3 4 6 Advanced H W Monitor ...

Страница 86: ...ons summary default setting Serial Port 1 2 3 4 Configuration Set Parameters of Serial Port 1 2 3 4 Restore AC Power Loss Power Off Power On Last State Select AC power state when power is re applied after a power failure EuP Power Control Disabled Enabled Configure Energy using Product EuP Power Control ...

Страница 87: ...uration Options summary default setting Serial Port Disabled Enabled En Disable specified serial port Change Settings Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Select a resource setting for Super IO device ...

Страница 88: ...uration Options summary default setting Serial Port Disabled Enabled En Disable specified serial port Change Settings Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Select a resource setting for Super IO device ...

Страница 89: ...Chapter 3 AMI BIOS Setup 75 Fanless Embedded Box PC AEC 6637 Device Type RS232 RS422 RS485 Configure COM2 operated as RS232 RS422 or RS485 ...

Страница 90: ...ration Options summary default setting Serial Port Disabled Enabled En Disable specified serial port Change Settings Auto IO 3E8h IRQ 11 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Select a resource setting for Super IO device ...

Страница 91: ...ration Options summary default setting Serial Port Disabled Enabled En Disable specified serial port Change Settings Auto IO 2E8h IRQ 11 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Select a resource setting for Super IO device ...

Страница 92: ...ded Box PC AEC 6637 3 5 Setup submenu Chipset Options summary default setting Onboard Device Configure Onboard Devices PCI IO Configuration South Bridge Parameters Memory Configuration Memory Parameters Graphic Configuration Graphic Parameters ...

Страница 93: ...1 Chipset Onboard Device Options summary default setting Onboard HD Audio Disabled Enabled Auto En Disabled HD Audio controller Intel LAN Controller Enabled Disabled En Disabled Intel i82579 NIC Realtek LAN Controller Enabled Disabled En Disabled Realtek RTL8111E NIC ...

Страница 94: ... Configuration Options summary default setting Power Mode 128MB 256MB Select the poer type used on the system PCIe MiniCard Slot Disabled Enabled Control the PCI Express Root Port PCIe Speed Auto Gen1 Gen2 Select PCI Express port speed Some PCIe carsd must set to Gen1 for operation ...

Страница 95: ...MI BIOS Setup 81 Fanless Embedded Box PC AEC 6637 ICC Spread Spectrum Disabled Enabled Enabled or Disable Clock spread spectrum control AAEON ICC Spread Spectrum 0 to 50 45 Spread spectrum level From 0 0 to 50 0 5 ...

Страница 96: ...pset Memory Configuration Options summary default setting DIMM Profile Default DIMM profile XMP Profile 1 XMP Profile 2 Select DIMM timing profile that should be used Memory Frequency Limiter Auto 1067 1333 1600 Maximum Memory Frequency Selections in Mhz Max TOLUD Dynamic ...

Страница 97: ...less Embedded Box PC AEC 6637 1 GB 1 25 GB 1 5 GB 1 75 GB 2 GB 2 25 GB 2 5 GB 2 75 GB 3 GB 3 25 GB Maximum Value of TOLUD Dynamic assignment would adjust TOLUD automatically based on largest MMIO length of install graphic controller ...

Страница 98: ...Fanless Embedded Box PC AEC 6637 3 5 4 Chipset Graphic Configuration Options summary default setting GTT Size 1MB 2MB Select the GTT Size Aperture Size 128MB 256MB 512MB Select the Aperture Size DVMT Pre Allocated 64MB 32MB 1024MB ...

Страница 99: ...ss Embedded Box PC AEC 6637 Select DVMT 5 0 Pre Allocated Fixed Graphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem 128MB 256MB Max Select DVMT 5 0 Total Graphic Memory size used by the Internal Graphics Device ...

Страница 100: ...p submenu Boot Options summary default setting Quiet Boot Disabled Enabled En Disable showing boot logo Launch I82579LM RTL8111E PXE OpROM Disabled Enabled En Disable PXE boot for I82579LM RTL8111E LAN Boot Option X XXXX Drive BBS Priorities The order of boot priorities ...

Страница 101: ...Chapter 3 AMI BIOS Setup 87 Fanless Embedded Box PC AEC 6637 3 6 1 Boot BBS Priorities Options summary default setting Boot Option x Disabled Device name Sets the system boot order ...

Страница 102: ...rd is set The password will be required during boot up or when the user enters the Setup utility Please Note that a User Password does not provide access to many of the features in the Setup utility Select the password you wish to set press Enter to open a dialog box to enter your password you can enter no more than six letters or numbers Press Enter to confirm your entry after which you will be p...

Страница 103: ...ss Embedded Box PC AEC 6637 confirmation Press Enter again after you have retyped it correctly Removing the Password Highlight this item and type in the current password At the next dialog box press Enter to disable password protection ...

Страница 104: ...and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options ...

Страница 105: ...Fanless Embedded Box PC AEC 6637 Chapter 4 Chapter 4 Drivers Installation ...

Страница 106: ...structions 4 Drivers will be installed automatically Step 2 Install Graphic Driver 1 Open the STEP2 VGA folder and select your OS 2 Open the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Note 1 This motherboard supports VGA and LVDS display devices In Single Display mode use the hot keys to switch between VGA to LVDS device or vice versa By defaul...

Страница 107: ... Open the setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 5 Install Audio Driver 1 Open the STEP5 Audio folder and select your OS 2 Open the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically Step 6 Install ME Driver 1 Open the STEP6 ME folder and select your OS 2 Open the exe file in the folder 3 F...

Страница 108: ...ollow the instructions 4 Drivers will be installed automatically Step 9 Install Serial Port Driver Optional For Fintek drivers 1 Open the STEP9 Serial Port Driver optional folder followed by the FintekT4R8 folder 2 Open the Setup exe file in the folder 3 Follow the instructions 4 Drivers will be installed automatically For ITE drivers For Windows 7 1 Change User Account Control settings to Never n...

Страница 109: ...Chapter 4 Driver Installation 95 Fanless Embedded Box PC AEC 6637 2 Reboot and log in as administrator 3 Run patch bat as administrator ...

Страница 110: ...Fanless Embedded Box PC AEC 6637 Appendix A Appendix A Watchdog Timer Programming ...

Страница 111: ...our application Configuring Sequence Description After the hardware reset or power on reset the ITE 8728F enters the normal mode with all logical devices disabled except KBC The initial state enable bit of this logical device KBC is determined by the state of pin 121 DTR1 at the falling edge of the system reset during power on reset There are three steps to complete the configuration setup 1 Enter...

Страница 112: ...f the next step 2 Modify the Data of the Registers All configuration registers can be accessed after entering the MB PnP Mode Before accessing a selected register the content of Index 07h must be changed to the LDN to which the register belongs except some Global registers 3 Exit the MB PnP Mode Set bit 1 of the configure control register Index 02h to 1 to exit the MB PnP Mode WatchDog Timer Confi...

Страница 113: ...er Programming 99 Fanless Embedded Box PC AEC 6637 WatchDog Timer Control Register Index 71h Default 00h WatchDog Timer Configuration Register Index 72h Default 00h WatchDog Timer Time out Value Register Index 73h Default 00h ...

Страница 114: ...guration_mode CALL Check_Chip mov cl 7 call Set_Logic_Device time setting mov cl 10 10 Sec dec al Watch_Dog_Setting Timer setting mov al cl mov cl 73h call Superio_Set_Reg Clear by keyboard or mouse interrupt mov al 0f0h mov cl 71h call Superio_Set_Reg unit is second mov al 0C0H mov cl 72h call Superio_Set_Reg game port enable mov cl 9 call Set_Logic_Device ...

Страница 115: ... 21h Enter_Configuration_Mode PROC NEAR MOV SI WORD PTR CS Offset Cfg_Port MOV DX 02Eh MOV CX 04h Init_1 MOV AL BYTE PTR CS SI OUT DX AL INC SI LOOP Init_1 RET Enter_Configuration_Mode ENDP Exit_Configuration_Mode PROC NEAR MOV AX 0202h CALL Write_Configuration_Data RET Exit_Configuration_Mode ENDP Check_Chip PROC NEAR MOV AL 20h ...

Страница 116: ...L Read_Configuration_Data CMP AL 12h JNE Not_Initial Need_Initial STC RET Not_Initial CLC RET Check_Chip ENDP Read_Configuration_Data PROC NEAR MOV DX WORD PTR CS Cfg_Port 04h OUT DX AL MOV DX WORD PTR CS Cfg_Port 06h IN AL DX RET Read_Configuration_Data ENDP Write_Configuration_Data PROC NEAR MOV DX WORD PTR CS Cfg_Port 04h OUT DX AL XCHG AL AH ...

Страница 117: ...perio_Set_Reg proc near push ax MOV DX WORD PTR CS Cfg_Port 04h mov al cl out dx al pop ax inc dx out dx al ret Superio_Set_Reg endp Set_Logic_Device proc near Set_Logic_Device proc near push ax push cx xchg al cl mov cl 07h call Superio_Set_Reg pop cx pop ax ret Set_Logic_Device endp Select 02Eh Index Port 02Fh Data Port Cfg_Port DB 087h 001h 055h 055h ...

Страница 118: ...ndix A Watchdog Timer Programming 104 Fanless Embedded Box PC AEC 6637 DW 02Eh 02Fh END Main Note Interrupt level mapping 0Fh Dh not valid 0Ch IRQ12 03h IRQ3 02h not valid 01h IRQ1 00h no interrupt selected ...

Страница 119: ...Fanless Embedded Box PC AEC 6637 Appendix B Appendix B I O Information ...

Страница 120: ...Appendix B I O Information 106 Fanless Embedded Box PC AEC 6637 B 1 I O Address Map ...

Страница 121: ...Appendix B I O Information 107 Fanless Embedded Box PC AEC 6637 ...

Страница 122: ...Appendix B I O Information 108 Fanless Embedded Box PC AEC 6637 B 2 Memory Address Map ...

Страница 123: ...Appendix B I O Information 109 Fanless Embedded Box PC AEC 6637 B 3 IRQ Mapping Chart ...

Страница 124: ...Appendix B I O Information 110 Fanless Embedded Box PC AEC 6637 B 4 DMA Channel Assignments ...

Страница 125: ...Fanless Embedded Box PC AEC 6637 Appendix C Appendix C RAID AHCI Settings ...

Страница 126: ... to SETUP RAID Mode Step 1 Copy below files from Driver CD Step7 RAID AHCI WinXP_32 to diskette Step 2 Connect the USB Floppy drive to the board and insert the diskette from previous step Step 3 Configure SATA Controller to RAID mode in BIOS SETUP Menu Advanced SATA Configuration SATA Mode RAID Mode ...

Страница 127: ...Appendix C RAID AHCI Settings 113 Fanless Embedded Box PC AEC 6637 Step 4 Configure DVD CD ROM drive as the first boot device Step 5 Save changes and exit BIOS SETUP ...

Страница 128: ...Appendix C RAID AHCI Settings 114 Fanless Embedded Box PC AEC 6637 Step 6 Press CTRL I to enter RAID Configuration Utility Step 7 Choose 1 Create RAID Volume ...

Страница 129: ...Appendix C RAID AHCI Settings 115 Fanless Embedded Box PC AEC 6637 Step 8 Configure RAID parameters for the system Step 9 Choose Create Volume and confirmed in next warning message ...

Страница 130: ...Appendix C RAID AHCI Settings 116 Fanless Embedded Box PC AEC 6637 Step 10 Exit RAID Configuration Utility and Reboot to DVD CD ROM device to install OS Step 11 Press F6 to install RAID driver ...

Страница 131: ...Appendix C RAID AHCI Settings 117 Fanless Embedded Box PC AEC 6637 Step 12 Press S to install RAID driver Step 13 Choose Intel R Mobile Express Chipset SATA RAID Controller ...

Страница 132: ...Appendix C RAID AHCI Settings 118 Fanless Embedded Box PC AEC 6637 Step 14 It will show the model you selected and then press ENTER Windows Setup will continue to install OS ...

Страница 133: ... to SETUP AHCI Mode Step 1 Copy below files from Driver CD Step7 RAID AHCI WinXP_32 to diskette Step 2 Connect the USB Floppy drive to the board and insert the diskette from previous step Step 3 Configure SATA Controller to RAID mode in BIOS SETUP Menu Advanced SATA Configuration SATA Mode AHCI Mode ...

Страница 134: ...Appendix C RAID AHCI Settings 120 Fanless Embedded Box PC AEC 6637 Step 4 Configure DVD CD ROM drive as the first boot device Step 5 Save changes and exit BIOS SETUP ...

Страница 135: ...Appendix C RAID AHCI Settings 121 Fanless Embedded Box PC AEC 6637 Step 6 Boot to DVD CD ROM device to install OS Step 7 Press F6 to install AHCI driver Step 8 Press S to install AHCI driver ...

Страница 136: ...I Settings 122 Fanless Embedded Box PC AEC 6637 Step 9 Choose Intel R 7 Series Chipset Family SATA AHCI Controller Step 10 It will show the model you selected and then press ENTER Windows Setup will continue to install OS ...

Отзывы: