5.4 Service Management

The MyM-3T contains 2 separate DVB-S/S2 
tuners and totally 3 services can be selected 
for each of output channels, named 

[CH-1], 

[CH-2] 

and 

[CH-3]

.

The list of services presents all received 
services from both tuner inputs. 

When one program (service) is selected, the 
box in front of the program name changes 
colour to green.

The service list gives following information:

Selected service   

Green colour indication

Service name

Program name

Provider

Name of satellite operator

Input

Indicates from which 
antenna input the service 
is received

SID

Service ID number (as 
received)

NOTE!

To detect whether a Common 

Interface module and smart card actually 
decrypts the programs is only possible 
by watching the outgoing signal on a TV-
set tuned to the correct frequency.

Menus and settings (continued)

5.5 CI menu

The MyM-3T contains 2 CI (Common 
Interface). CI 1 decrypt services for output 
Ch1 and Ch2. The CI 2 decrypt services for 
output Ch 3. In menu you get information 
about CAM and card. 

In the Advanced settings menu you can 
change timing settings for the used CAM if 
there is a need for changing that. After a 
change is made the “Save” button must be 
clicked on. If changes are made and does not 
work, you can get the default settings agaion
by a click on the “Reset” button and a click on 
the “Save” button.

Содержание MyM-3TMicro Master

Страница 1: ...1 1 MyM 3TMicro Master Installation Guide design for TV English...

Страница 2: ...settings 5 Menus and settings 5 1 Overview menu 5 2 Input settings 5 3 Output settings 5 4 Service management 5 5 CI menu 5 6 System options 6 Installation and Configuration examples 7 Technical speci...

Страница 3: ...es DVB S and DVB S2 transmissions The MyM 3T unit is delivered with hardware and software that supports DVB S S2 reception MPEG2 MPEG4 decoding DSB RF modulation with NICAM or A2 audio IP control and...

Страница 4: ...ice see page 3 for contact info English Important information about power supply to MyM 3T unit To avoid problems with theMyM 3T its is important to use the supplied power supply Operation with other...

Страница 5: ...a Common Interface module into this slot Supports decryption for Channel 1 and 2 5 Common Interface 2 Insert a Common Interface module into this slot Supports decryption for Channel 3 6 Ethernet port...

Страница 6: ...the default IP address 192 168 0 20 First time installation requires that you set a static IP address on your computer For example set your PC to IP address 192 168 0 19 and Net mask 255 255 255 0 En...

Страница 7: ...ng your PC to the MyM 3T Connect the MyM 3T to the supplied DC power supply See section 6 for installation Next connect your PC to the MyM 3T with a network cable Start your web browser Internet Explo...

Страница 8: ...rdware revision serial number and current IP Network settings All necessary settings can be made in the web GUI via a web browser When first connection is made with the MyM 3T following overview menu...

Страница 9: ...ngs As the MyM 3T contains 2 separate tuners start by selecting either Tuner 1 or Tuner 2 Bandwidth can be selected between 6 7 or 8 MHz Write the center frequency of the wanted Mux and press Set 5 Me...

Страница 10: ...rsonal preference The Channel Indicator will enable you to detect on a TV screen which programs that are transmitted from the MyM 3T Press Set after each entering National Subtitle Type Set type of su...

Страница 11: ...Select here if loopthrough for input antenna signal shall be On or Off 5 Menus and settings continued 5 3 Output settings continued Auto conversion Converts subtitling to fit actual picture aspect rat...

Страница 12: ...ed SID Service ID number as received NOTE To detect whether a Common Interface module and smart card actually decrypts the programs is only possible by watching the outgoing signal on a TV set tuned t...

Страница 13: ...ves statistics of uptime and possible re starts The log can be cleared in order to have a clean sheet after installation IP settings This section shows current IP address Netmask and Gateway settings...

Страница 14: ...s in public places Before connecting power to the MyM 3T make sure that all other connections have been made A coaxial cable of good quality with an F connector should be connected to the Antenna inpu...

Страница 15: ...t level Typ 80 dB V fixed Built in aerial amplifier 5 dB RF output connector Type F female 75 Input frequency 950 2150 MHz Symbol rate 1 45 Msymbols s Connectors Type F female 75 Input level 65 to 25...

Страница 16: ...16 16 The document for Declaration of Conformity is available for download from www a2b se Further information at www a2b se English 8 Declaration of Conformity...

Страница 17: ...little or no manual configuration Common Interface Connector for a PCMCIA module used for decrypting encrypted TV programs Modules should comply with the DVB CI standard SD Standard definition TV 576...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...ics AB S dra All n 23 25 591 37 Motala P O Box 14 591 21 Motala SWEDEN Phone 46 141 229100 Fax 46 141 229101 E mail market a2b se To view our full line of Professional Products visit our Web site www...

Отзывы: