3 INSTALLATION
Pag. 8 di 37
3
INSTALLATION
Verify the nominal capacity of equipment
To check the nominal capacity of equipment, consult the identification label (
Check operating pressure and flow rate oil
A.T.I.B. advises to respect the hydraulic flow rates and operating pressures shown in
, in
order to optimize the operation of the equipment and avoid problems during the work or
commissioning phases. The values are indicative and may vary depending on the equipment.
TIPO and ISO
PORTATA (l/mm)
Max operating
pressure (Bar)
Min.
Max.
racommended
883 ISO II [2400kg.@500mm.]
10
20
15
80
883 ISO III [3000kg.@500mm.]
15
25
20
80
883 ISO III [4500kg.@500mm.]
15
25
20
80
883 ISO IV [4500kg.@600mm.]
30
60
45
80
883 ISO IV [7000kg.@600mm.]
35
60
45
80
Tab 2
The forklift manufacturer is responsible for calculating the residual capacity of the
forklift /equipment assembly.
WARNING!!
RESPECT THE MAXIMUM WORKING PRESSURES INDICATED
WARNING
Make sure that the operator of the forklift is aware of the maximum capacity of the
attachments, so as NOT to pose a danger to himself and to the people who work in his
vicinity.