A SYSTEMS SR703 Скачать руководство пользователя страница 4

4

SR703 CONTRACTOR AMPLIFIER

English

INTRODUCTION

Congratulations on your purchase of the Asystems 

SR703 professional contractor power amplifier. The SR 

series is a line of power amplifiers specifically designed 

for contracting application� The SR703 has independent 

channels and is able to drive 200V, 140V, 100V, 70V, 

50V or 25V constant voltage lines� Each channel has 

its own power transformer (toroidal type) secondary to 

provide maximum audio separation (minimum sound 

leakage) between two channels, minimizing interaction 

that  can  otherwise  occur  on  amplifiers  with  a  common 

power supply�

FEATURES

√ 

Automatic dual-speed, high efficiency fan cooling

√ 

Rear panel detented gain controls for security and 

resetability

√ 

Stereo, bridge or parallel operating modes

√ 

XLR and barrier strip inputs

√ 

XLR in and outs for multiple amplifier operation & 

easy signal pass-through

√ 

Fully short-circuit, temperature and DC offset 

protection

√ 

Barrier strip connection determines output mode - 

25V, 70V, 100V and direct low-impedance outputs 

available

√ 

Toroidal output transformers provide full electrical 

isolation and meet worldwide safety agency approval

√ 

45Hz subsonic filter prevents speaker transformer 

saturation with minimal effect on program material

√ 

Power-up muting

PRECAUTIONS

1.

  When first powering up the amp, keep the amplifier 

gain controls all the off, in order to block potentially 

damaging or annoying sounds caused by defective 

cables or hookups� When turning up the gain, do it 

gradually, until normal operation is verified� These 

precautions are necessary with all high-power 

amplifiers, since they have enough power to blow 

most speakers in abnormal situations�

2.

  Check local voltage levels before connecting the AC 

plug� Under no circumstances should the grounding 

pin of the power cable be defeated�

3.

 

 Speaker Output Shock Hazard! 

The SR703 amps 

are capable of producing hazardous output voltages� 

To avoid electrical shock, make sure the cover is in 

place over the output terminals, and do not touch 

any exposed speaker wiring while the amplifier is 

operating�

ABOUT THIS MANUAL

Please  be  reminded  that  a  power  amplifier  is  a  high-

current, high-power device and should be treated with 

care and respect� Please read this manual before 

connecting and operating your unit, and file it in a safe 

place for future reference�

FRONT PANEL

1. Power Switch

The power ON/OFF switch with an LED indicator�

2. Protect LED Indicators

The SR703 features several types of protection to prevent 

damage to the circuitry during turn-on or fault conditions� 

If the LEDs light up, this indicates that one of the various 

protections  is  safeguarding  the  different  sections  of  the 

amplifier and in these cases, the power output is normally 

switched off until normal operating conditions are restored.
• 

Loudspeaker protection: the power-on protection relay 

prevents damaging thumps to the speakers as the 

power comes on� When the amp is switched on, the 

protect LED will light for a few seconds, and then go out, 

indicating that the relay has closed�

• 

Thermal protection on the heat sink: If the amp 

overheats, thermal shutdown protects the circuitry until 

the temperature is reduced to a safe level�

• 

Short circuit protection: The Protect LED Indicator 

will also light up if the speaker terminals are short-

circuited, or the impedance of the load is too low� In 

these circumstances, the Protect LED will stay on until 

the fault conditions are rectified.

Some  protection  situations  require  the  amplifier  to  be 

switched  off  and  then  back  on  for  normal  operating 

conditions to be restored�

3. Signal “Status” LED Indicator

Each channel of the SR703 features a signal LED to show 

that there is an audio signal at the input to the channel� 

The threshold for the indicator is -26dB, which should be 

enough to avoid noise triggering the LED�

4. Limit LED Indicator

The SR703 has a built-in limiter on each channel to 

prevent clipping� Should the signal reach a level high 

enough to cause clipping, the limiter momentarily reduces 

the input signal level, just enough to prevent it� The limit 

LED lights whenever this occurs�

Содержание SR703

Страница 1: ...User s Manual Manual del Usuario Contractor Power Amplifier Amplificador de Potencia Para Contratista SR703...

Страница 2: ...CIONES 10 ACERCA DE ESTE MANUAL 10 PANEL FRONTAL 10 PANEL POSTERIOR 11 CONEXIONES DE ENTRADA 12 CONEXIONES DE SALIDA 12 ESPECIFICACIONES 14 DIMENSIONS DIMENSIONES 15 Asystems reserves the right to alt...

Страница 3: ...paratus during lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power su...

Страница 4: ...er is in place over the output terminals and do not touch any exposed speaker wiring while the amplifier is operating ABOUT THIS MANUAL Please be reminded that a power amplifier is a high current high...

Страница 5: ...ther SR or other amplifier 9 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the amplifiers In Parallel operation one signal is tre...

Страница 6: ...f before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Direct Low Impedance Output connection for SR703 bridge mono mode Output co...

Страница 7: ...refer to the Rear Panel section on page 5 Low Impedance and Distributed Speakers If your application calls for connection of an 8 ohm speaker and a distributed line to the same amplifier channel the S...

Страница 8: ...mpedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat sink overhea...

Страница 9: ...9 SR703 AMPLIFICADOR DE POTENCIA PARA CONTRATISTA Espa ol...

Страница 10: ...os a la salida Para evitar descargas el ctricas aseg rate de que la cubierta este encima de las terminales de salida y no toques ning n cable de altavoz que este expuesto mientras el amplificador este...

Страница 11: ...amplificador 9 Selector Est reo Paralelo Bridge En operaci n est reo dos se ales separadas ser n transmitidas por los canales 1 y 2 de los amplificadores En operaci n en Paralelo una se al es tratada...

Страница 12: ...ado antes de cambiar cualquier conexi n de salida Liberal los tornillos de las terminales inserta las conexiones de los cables debajo de los tornillos Aprieta firmemente las terminales de los tornillo...

Страница 13: ...or favor refi rete a la descripci n previa del Panel Trasero Altavoces Distribuidos y de Baja Impedancia en los Amplificadores SR703 SI tus aplicaciones necesitan la conexi n de altavoces de 8 ohm y u...

Страница 14: ...esbalanceada 20k 10k ohm Factor Damping 200 direct output Relaci n S R Menor a 100dB debajo de la salida medida 20Hz 20kHz Circuitos de Protecci n Protecci n de offset de voltaje de salida Protecci n...

Страница 15: ...15 SR703 CONTRACTOR AMPLIFIER Appendix DIMENSIONS DIMENSIONES Measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas 132 5 2 480 19...

Страница 16: ...www asystems sys com...

Отзывы: