A.R.I. D-060 Скачать руководство пользователя страница 4

4

 

IOM

 

 

 

Safety Instructions - Commissioning and Operation

 

1.

 

Read carefully the operation instructions prior to any attempt to operate the product. 

2.

 

Observe the safety stickers on the product and never perform any operation contradicting the instructions given. 

3.

 

In order to achieve maximum performance and smooth operation of the product, it is crucial to perform the startup and first 
operation procedures exactly as described in this manual. 

4.

 

In cases where formal commissioning procedure is required, it should be done by an authorized A.R.I. technician prior to the 
first operation of the product. 

 

Safety Instructions - Maintenance

 

Before any maintenance or non-regular operation, please read the following: 

1.

 

Servicing the product should be done only by qualified technicians for this type of work. 

2.

 

Make sure that you know the exact type of the system fluid. Act accordingly and comply with all the relevant standards and 
regulations set for handling this type of fluid. 

3.

 

Before disconnecting the product from the system and before releasing the residual pressure do NOT: 
-

 

loosen or unscrew the product bolts; 

-

 

remove any protection cover; 

-

 

open any service port. 

4.

 

Before any maintenance or non-regular operation, shut off the Isolation valve and release the residual pressure: 
A.

 

For air valves with a pressure release outlet, slowly open the pressure release plug or the ball valve and make sure that all 

pressure is released. Please note that some air release valves, especially the waste water models, may contain a significant 
volume of compressed gas with accumulated energy! 
B.

 

For air valves without a pressure release outlet, slowly unscrew the flange bolts until all the pressure is released from the 

valve. 

5.

 

Make sure the air valve is empty of all liquid prior to commencing maintenance. 

6.

 

Remove the product from the line only after ensuring that internal pressure has been released. 

7.

 

Place warning signs around the work area as required by the local standards and procedures. 

8.

 

Inspect the product’s safety stickers and replace any damaged or faded sticker. 

9.

 

Manual cleaning of the product and/or its components using high water pressure or steam should be performed in 
accordance with its specific cleaning instructions, the local standards and regulations and without endangering the operator 
or the vicinity 

10.

 

Manual cleaning of product and/or its components using acid or other chemical agents should be performed in accordance 
with the specific cleaning instructions, the relevant safety instructions for using that chemical as given by its supplier, the local 
standards and regulations and without endangering the operator or his vicinity. 

11.

 

For products used in potable water systems, if it is required to disinfect the product, do so according to the local water 
authority standards and regulations before putting the product into service. 

 
 

Safety Instructions - Before returning to regular  operation

 

1.

 

Re-assemble any protection covers or protection mechanisms removed during service or maintenance operations. 

2.

 

Make sure that all the tools, ladders, lifting devices, etc. used during the maintenance procedures are taken away from the 
product area and stored. 

3.

 

Remove grease and fat material residues in order to avoid slipping. 

4.

 

In order to return the product to regular operation, follow the First Start-up Operation instructions as detailed in your user 
manual. 

 

 

Содержание D-060

Страница 1: ... an Automatic Air Release valve and an Air Vacuum valve The Air Release component is designed to automatically release small pockets of air to the atmosphere as they accumulate along a pipeline or piping system when it is full and operating under pressure The Air Vacuum component is designed to automatically discharge or admit large volumes of air during the filling or draining of a pipeline or pi...

Страница 2: ...d hereto may be used in any form or by any means without the prior written consent from A R I If you received this Disclaimer and or in any document enclosedheretoinerrororby mistakeorifthis Disclaimerand orinanydocumentenclosedheretoisnotintendedforyou pleasenotifyA R I inwriting immediately A R I assumes that all users understand the risks involved within this Disclaimer and or in any document e...

Страница 3: ...ons table doesn t include pressure changes caused by water hammer and pressure surge effects Use the product only according to its designated pressure rate specifications 10 Use the product only for its intended use as designed by A R I Any misuse of the product may lead to undesired damages and may affect your warranty coverage Please consult with A R I prior to any non regular use of this produc...

Страница 4: ...Forairvalveswithout apressurereleaseoutlet slowlyunscrewtheflangeboltsuntilallthepressureisreleased fromthe valve 5 Make sure the air valve is empty of all liquid prior to commencing maintenance 6 Removetheproductfromthelineonly afterensuringthat internalpressurehasbeen released 7 Place warning signs around the work area as required by thelocal standards and procedures 8 Inspecttheproduct ssafety ...

Страница 5: ... Isolating Valve at 45 to Air Valve outlet Two Air Valves on an Air Trap with separate Isolating Valves Air Valve outlets face outward and the Isolating Valves at 45 to Air Valve outlets Two Air Valves on a shared Isolating Valve Air Valves outlets face outward and the Isolating Valve at 45 to Air Valve outlets Underground Installations Underground installations require a venting pipe from the man...

Страница 6: ...s up to 12 300mm in diameter D the Air Trap diameter d should be the same as the pipeline diameter For larger pipelines of up to 60 1500mm in diameter D the Air Trap diameter d should be 60 of the pipeline diameter For larger than 60 1500mm pipelines D the Air Trap diameter d should be 35 of the pipeline diameter The Air Trap length H should allow easy access to the air valve from below and should...

Страница 7: ...Place washers on each of the bolts nuts that connect the air valve flange to the isolating valve flange 7 Tighten all the bolts and nuts using the crossover method 8 The closure tightness of the bolts and nuts shall be according to the standard torque for their specific size 9 Use ring wrench keys for the closing and opening of all bolts of the air valve including the flange bolts 2 4 Directions f...

Страница 8: ... is essential to efficiently drain the system The automatic air release component releases entrapped air in pressurized systems As the system starts to fill the valve functions according to the following stages 1 Air in the pipeline is discharged by the valve 2 Liquid enters the valve lifting the float which pushes the sealing mechanism to its sealing position 3 Entrapped air which accumulates at ...

Страница 9: ...fety instructions standards and work regulations 4 1 Preparation Releasing Pressure Shut the isolating valve located on the riser under the air valve Option A Using two combination spanners partially unscrew the bolts connecting the air valve to the riser in order to release the pressure Wait till the pressure is released Option B for air valves with Plug Use a ratchet box wrench to gradually rele...

Страница 10: ...e Strainer the Clamping Stem the Float and the Rolling Seal under clean running water 5 Check to make sure that the Rolling Seal is not damaged torn or cracked and is located precisely in the middle of its groove in the Float 6 Replace the Rolling Seal if it is damaged or has been removed from the float 7 Reassemble the air valve in the reverse order 8 First insert half the length of the Rolling S...

Страница 11: ...11 IOM S 050 AUTOMATIC VALVE ASSEMBLY BOM TABLE AND DRAWING 1 Body 2 Discharge Outlet Elbow 3 Rolling Seal 4 Float 5 Clamping Stem 6 O ring 7 Base 8 Strainer ...

Страница 12: ...g the Strainer the Clamping Stem the Float and the Rolling Seal under clean running water 5 Check to make sure that the Rolling Seal is not damaged torn or cracked and is located precisely in the middle of its groove in the Float 6 Replace the Rolling Seal if it is damaged or has been removed from the float 7 Reassemble the air valve in the reverse order 8 First insert half the length of the Rolli...

Страница 13: ...13 IOM S 050C S 052 AUTOMATIC VALVE ASSEMBLY BOM TABLE AND DRAWING 1 Shell 2 O ring 3 Discharge Outlet 4 Body 5 Rolling Seal 6 Float 7 Clamping Stem 8 O ring 9 Base 10 Strainer 9 10 ...

Страница 14: ...ing Seal under clean running water 6 Check to make sure that the Rolling Seal is not damaged torn or cracked and is located precisely in the middle of its groove in the Float 7 Replace the Rolling Seal if it is damaged or has been removed from the float 8 Reassemble the air valve in the reverse order 9 First insert half the length of the Rolling Seal into the groove in the Body and then push it th...

Страница 15: ...15 IOM S 050L AUTOMATIC VALVE ASSEMBLY BOM TABLE AND DRAWING 1 Body 2 Discharge Outlet 3 Rolling Seal 4 Clamping Stem 5 Float 6 O ring 7 Body Extension 8 Plug 9 Base 10 Strainer 9 10 ...

Страница 16: ...m steps 1 3 of the Basic Periodic Maintenance found above 2 Unscrew and remove the Discharge Outlet 3 Remove the Roll pin with the aid of a hand punch small hammer and pliers 4 Press down on the threaded end of the Orifice and Float Assembly that extends out from the top the Cover remove and place it on a flat surface for the next step 5 Remove the damaged Rolling Seal by extracting it from both e...

Страница 17: ...UTOMATIC VALVE ASSEMBLY BOM TABLE AND DRAWING 1 Air Release Outlet 2 Circlip 3 Cover 4 O Ring 5 Orifice seat 6 Rolling Seal 7 Lever 8 Roll Pin 9 Float 10 O Ring 11 Bolts Nuts Washers 12 Body 13 Adaptor 10 9 13 12 11 ...

Страница 18: ...ime and or accumulated scale 5 Check that the Orifice Seal is not damaged torn and or cracked 6 In case the Orifice Seal is damaged consult your dealer 7 Reassemble the air valve in the reverse order 8 First insert the Float and then place the O ring in the groove 9 Place the Cover on the Body insert the Bolts and Washers and tighten the Nuts 10 Tighten all the Bolts and Nuts using the crossover m...

Страница 19: ...19 IOM AIR VACUUM VALVE ASSEMBLY BOM TABLE AND DRAWING 1 Cover Assembly 2 Float 3 O ring 4 Bolts Nuts 5 Body ...

Страница 20: ...t a minute and open it again very fast If leaking continues follow instructions for 4 2 Maintenance Automatic Air Release Component Leakage from the Large Orifice Dirt particles stuck on the Orifice Seal Orifice Seat or on the Float Shut the isolating valve wait a minute and open it again very fast If leaking continues follow steps for 4 3 Maintenance Air Vacuum Valve Component ...

Страница 21: ...e nor does this warranty extend to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or property loss of use of the products loss of goodwill loss of profits or any other contingent liabilities of any kind or character alleged to be the cause of loss or damage to the purchaser This warranty does...

Отзывы: