background image

The first time the user interface is turned ON, the clock must be set to the 

current time.  

Set the Speed and Start/Stop times for 
the  motor  in  the  Set  Schedule  menu. 

The  schedule  is  based  on  a  24-hour 

cycle  and  will  repeat  each  day  of  the 

week. The highest speed rating for the 

V-Green  motor  is  3450  RPM  and  the 

lowest is 600 RPM.

SET CLOCK Menu Buttons

1.  Turn the selector knob (see Figure 5) to SET CLOCK.

2.  At any time, the user can press BACK to return to the previous area.

3.  Press + or – to change the Month. Press → to move to the Day setting.

4.  Press the + or – to change the Day. Press → to move to the Year setting.

5.  Press + or – to change the Year. Press → to move to the Hour setting.  

6.  Press + or – to change the Hour. Press → to move to the Minute setting.

7.  Press + or – to change the Minute. Press → to move to the AM or PM  
 

setting.

 

8.  Press SET when the time is correct.

 

9.  Press SET again if the user needs to make additional changes.    

 

 

The cursor returns to the Month setting. 

 

10. If the date and time are correct, move the selector knob to Set    

 

 

Schedule, Step 1.

NOTE:

 Neither of the Override buttons affects this menu. 

The message “Invalid Key” appears if the user presses an Override button. 

Key Lockout Feature

 

The A. O. Smith User Interface has a key lockout feature to prevent 

unwanted changes to the settings.  To lock the keys, hold down the 

“+, -, and SET” buttons for more than 3 seconds.  The display will then 

show a symbol of a key indicating the buttons are locked.  The user 

can unlock the keys by holding down the same buttons for more than 3 

seconds. 

Custom Schedule Table

Step 1

Step 2

Step 3

Speed

Start Time
Stop Time

Set STEP 1 Menu Buttons

2.  The first digit in the Speed setting flashes. Press + or – to change the    

 

first digit in the Speed setting. The number increases one unit at a time.

3.  Press → to move to the second digit in the Speed setting. Press + or – to  

 

change the second digit. The number increases one unit at a time.

4.  Press → to move to the third digit in the Speed setting. Press +    

 

 

or – to change the third digit. The number increases one unit at a time.

5.  Press → to move to the fourth digit in the Speed setting. Press + or – to    

 

change the fourth digit. The number increases five units at a time. 

6.  Press → to move to the Start Time setting.
7.  Press the + or – to change the Hour. Press → to move to the Minute setting.
8.  Press the + or – to change the Minute. Press → to move to the AM or PM  

 

setting.

9.  Press → to move to the Stop Time setting. Follow steps 6 through 8 to    

 

set the Stop Time settings.

10. Press Set to save the settings. If necessary, press Set again to move the   

 

cursor back to the first digit.

Unless changes are necessary, move the selector knob to Steps 2 and 3 and 

repeat procedural steps 2 through 10.

Set the Clock

Set the Schedule

Prime Configuration

Setup

Use the following table to enter a personalized schedule

Custom Schedules

1.  Make certain the selector knob points to Set Schedule, Step 1.

Setup allows the user to configure the following parameters:
 

•  Freeze Protection  

 

•  Reset Factory Defaults

 

•  Auxiliary Load Settings   

•  Set Contrast Level

 

•  Prime Settings   

 

Setup Menu Buttons

 

Freeze Protection can be either enabled or disabled when the user turns the 

User Interface selector knob to Setup.  If it is enabled, the user will be able to set 

the temperature at which the pump will turn on.  The control is designed to run 

the pump for 8 hours at 2600 RPM if the temperature drops below the setpoint.

Freeze Protection

The Auxiliary Load is a relay inside the control designed to provide AC power to 

a load that should not be energized without adequate water flow from the pump 

(i.e. heater, booster pump, salt water chlorinator).  

The control is designed to turn on the Auxiliary 

Load relay when the pump speed is above the 

MINIMUM ON SPEED (default is 2000 RPM).  

The Auxiliary Load relay will stay closed as 

long as the pump speed is above the MINI-

MUM ON SPEED.  In addition, the control can 

be programmed to limit the amount of time 

the Auxiliary Load relay is closed in a 24-hour 

period.  For example, if the pump runs at 3450 

RPM for 12 hours a day, but the auxiliary load 

only needs to be powered for 6 hours, the user can set the MAXIMUM RUN 

TIME.  
 

1.  Make certain the selector knob points to Setup.

 

2.  Press → one time to change the Auxiliary Load settings.  Press SET to    

 

  enter “change mode.”  Press + or – to increase or decrease the Minimum   

 

  Speed. Press → to change the Maximum Run Time.  Press the + or – to    

 

      increase or decrease the Maximum Run Time. Press SET to save changes.

  1.  Make certain the selector knob points 

    to Setup.
  2.  Press or – to change the 

    Freeze Protection setting. 

    Press Set to save any changes.

WARNING:

  Freeze Protection will ONLY function with the selector knob in the 

RUN position.  Damage may occur to the user’s pool system if Freeze Protection 

is enabled and the switch is not in the RUN position.

Auxiliary Load Setup

The priming speed and time can be adjusted within this menu.  The minimum 

priming speed is 1500 RPM.  The maximum priming time is 10 minutes.
 

1.  Make certain the selector knob points 

 

 

to Setup.

 

2.  Press → two times to change the 

 

 

Prime settings.  

 

3.  Press SET to enter “change mode.”  

 

4.  Press + or – to increase or decrease 

 

 

the Prime Speed. 

 

5.  Press → to change the Prime Time.  

 

 

Press the + or – to increase or decrease the Maximum Run Time. 

 

6.  Press SET to save changes.

This menu will permit the user to reset all settings in the control to the factory 

default settings.
 

1.  Make certain the selector knob points 

 

 

to Setup.

 

2.  Press → three times to Reset to 

 

 

Factory Default settings. Press SET 

 

 

two times to verify intent to Reset to 

 

 

the Factory Default settings.

This menu will change the contrast of the LCD screen to optimize viewing for 

various lighting conditions.
 

1.  Make certain the selector knob points to Setup.

 

2.  Press → four times to change the Contrast setting.  Use + and – to 

 

 

adjust the contrast level.  Press SET to save the setting.

The V-Green is equipped with both High and Low Overrides, which can be 

engaged to temporarily run at higher or lower speeds between 600 and 3450 

RPM.  Override High is recommended for high flow uses such as a pool heater 

startup, backflush, filtering, and for cleaner water requirements that exist 

outside of the daily operating schedule.  The Override Low is recommended 

for low circulation requirements that exist outside of the daily operating 

schedule.  Once an Override (either High or Low) is completed, the motor will 

automatically return to the programmed schedule.  
 

1.  Depending on the Override desired, press the appropriate button. 

 

2.  Press SET to change the Override settings. 

 

3.  Press + or – to increase or decrease the first digit in the speed.  The  

 

 

maximum speed is 3450 RPM and the minimum speed is 600 RPM. 

 

4.  Press (arrow symbol to the right) to move to the second, third, and  

 

 

fourth digits in the speed. 

 

5.  Press SET to save the speed setting.  The Override Duration Time  

 

 

setting flashes. 

 

6.  Press + or – to increase or decrease the Override Duration Time.  The  

 

 

maximum duration is 24 hours and the minimum is .5 hours (half an hour). 

 

7.  Press SET to save the Override Duration Time setting. 

Reset Factory Defaults

Set Contrast

Override High or Low

Содержание V-Green Green Choice

Страница 1: ...VARIABLE SPEED QUICK START GUIDE Premium Efficiency Variable Speed Motor v...

Страница 2: ...ut of the Box Operations Pre Set Schedule The V GreenTM motor is programmed with a pre set schedule that complies with California Title 20 requirements Only the clock setting is required to enable the...

Страница 3: ...o the AM or PM setting 8 Press SET when the time is correct 9 Press SET again if the user needs to make additional changes The cursor returns to the Month setting 10 If the date and time are correct m...

Страница 4: ...Press or to change the third digit The number increases one unit at a time 5 Press to move to the fourth digit in the Speed setting Press or to change the fourth digit The number increases five units...

Страница 5: ...The Auxiliary Load relay will stay closed as long as the pump speed is above the MINI MUM ON SPEED In addition the control can be programmed to limit the amount of time the Auxiliary Load relay is cl...

Страница 6: ...V Green is equipped with both High and Low Overrides which can be engaged to temporarily run at higher or lower speeds between 600 and 3450 RPM Override High is recommended for high flow uses such as...

Страница 7: ...Duration 8 OFF Quick Start Guide Using custom schedule Menu Structure for Selector Knob Positions q Observe all safety warnings and cautions q Make certain the motor is prop erly wired refer to user m...

Страница 8: ...ctrical Products Company 531 North Fourth Street Tipp City OH 45371 Customer Service 800 262 6484 Fax 937 667 5030 1011982 003 5 2011 Copyright 2011 A O Smith Corporation Distribution Services 1325 He...

Отзывы: