8

WARNING

Explosion Hazard

If the temperature and pressure relief 

valve is dripping or leaking, have a 

qualified person replace it.
Examples of a qualified person include:
licensed plumbers, authorized gas 

company personnel, and authorized 

service personnel.
Do not plug valve.
Do not remove valve.
Failure to follow these instructions can 

result in death or explosion.

FIGURE 11

TEMPERATURE AND PRESSURE

RELIEF VALVE INSTALLATION

TEMPERATURE AND

PRESSURE RELIEF 

VALVE

DISCHARGE LINE

3/4 INCH MIN.

DO NOT CAP OR PLUG

6 INCH

MAXIMUM

AIR GAP

DRAIN PAN

DRAIN

Closed System/Thermal Expansion

As water is heated, it expands (thermal expansion). In a  
closed system, the volume of water will increase. As the 
volume of water increases, there will be a corresponding 
increase in water pressure due to thermal expansion. 
Thermal expansion can cause premature tank failure 
(leakage). This type of failure is not covered under the 
limited warranty. Thermal expansion can also cause 
intermittent temperature-pressure relief valve operation: 
water discharged from the valve due to excessive 
pressure build up. The temperature-pressure relief 
valve is not intended for the constant relief of thermal 
expansion. This condition is not covered under the limited 
warranty. 

A properly-sized thermal expansion tank should be 
installed on all closed systems to control the harmful 
effects of thermal expansion. Contact a plumbing service 
agency or your retail supplier regarding the installation of 
a thermal expansion tank.

Do not plug the temperature and pressure relief 
valve.

Solar Control Systems

Solar control systems used with this solar storage tank 
must not allow temperatures in the tank to exceed 180°F 
and must protect the system from freeze damage when 
the temperatures approach freezing.

This solar storage tank does not contain a heat 
exchanger; therefore, only potable (drinkable) water may 
be allowed to enter the tank.  If this solar storage tank is 
installed in a system using any heat transfer 

fl

 uid other 

than potable water, a separate heat exchanger must be 
installed.  Heat exchangers used in conjunction with this 
solar storage tank must provide adequate protection of 
contamination of potable water by toxic 

fl

 uids used in 

heat exchange systems.

If this water heater is used as a solar storage heater or as 
a backup for the solar storage system, the water supply 
temperatures to the water heater tank may be in excess 
of 120°F.  A mixing valve or other temperature limiting 
device should be installed in the water supply line to limit 
the supply temperature to 120°F.

Temperature and Pressure  Relief Valve

For protection against excessive pressures and 
temperatures, a temperature and pressure relief valve must 
be installed in the opening marked “T & P RELIEF VALVE” 
(See Figure 11).

Caution:  To reduce the risk of excessive pressures and 
temperatures in this solar storage tank water heater, 
install temperature and pressure relief protective 
equipment required by local codes, but no less than 
a combination temperature and pressure relief valve 
certi

fi

 ed by a nationally recognized testing laboratory that 

maintains periodic inspection of the production of listed 
equipment or materials, as meeting the requirements 
for Relief Valves and Automatic Shutoff Devices for Hot 
Water Supply Systems, ANSI Z21.22 - current edition. 

Содержание Solar Storage Tank Water Heater

Страница 1: ...f installation 5 Place of Purchase Solar Storage Tank Water Heater Safety 2 Installing Your Solar Storage Tank Water Heater 3 9 Unpacking Instructions 3 Location Requirements 4 Electrical Requirements...

Страница 2: ...eeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink befor...

Страница 3: ...e necessary skills required to properly install this solar storage tank water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the inst...

Страница 4: ...ge tank water as shown below to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank The drain pan must limit the water level to a...

Страница 5: ...EATING ELEMENT 2 Disconnect the electric power 3 Loosen the screw holding the junction box cover to the top of the solar storage tank water heater and set aside 4 Connect the electrical supply to the...

Страница 6: ...Figure 8 Connect the cold water supply 3 4 NPT to the fitting marked Cold Water In Connect the hot water supply 3 4 NPT to the fitting marked Hot Water Out IMPORTANT Some models may contain energy sa...

Страница 7: ...10 HOT COLD HOT COLD HOT COLD RECIRCULATION RETURN SPRING CHECK VALVE COLD WATER SUPPLY MIXING VALVE MIXED HOT WATER OUTLET SPRING CHECK VALVE COLD WATER SUPPLY MIXING VALVE MIXED HOT WATER OUTLET SO...

Страница 8: ...Control Systems Solar control systems used with this solar storage tank must not allow temperatures in the tank to exceed 180 F and must protect the system from freeze damage when the temperatures app...

Страница 9: ...n the discharge line Must not be capped blocked plugged or contain any valve between the relief valve and the end of the discharge line Must terminate a maximum of six inches above a floor drain or ex...

Страница 10: ...stat High Limit Control section to properly reset the high limit control If the high limit control switch continues to shut off the water heater contact a qualified person for service Water Temperatur...

Страница 11: ...be made by qualified service personnel 1 Disconnect the electric power 2 Remove the access cover and fold up the insulation from the thermostat Do not remove the plastic cover 3 Using a screwdriver to...

Страница 12: ...an 3 8 Significant sections of the support wire approx 1 3 or more of the anode rod s length are visible If the anode rod shows signs of either or both it should be replaced NOTE Whether reinstalling...

Страница 13: ...UTION Do not turn on power to the water heater unless it is completely filled with water To ensure that the tank is full open a hot water faucet and allow the water to run until the air is purged and...

Страница 14: ...ts set too low 5 Sediment or lime in tank 6 Heater too small for job 7 Wrong piping connections 8 Leaking faucets 9 Wasted hot water 10 Long runs of exposed pipe 11 Hot water piping on outside wall 1...

Страница 15: ...Item number 3 Parts description LEGEND Not supplied on some models Electrical Assisted only REPAIR PARTS LIST ITEM NO PARTS DESCRIPTION 13 13 12 11 9 8 8 10 5 2 14 16 6 7 3 4 and 1 15 5 5 COLD INLET N...

Страница 16: ...6603461G RED HEATING ELEMENT GROUND SCREW ELECTRICAL SERVICE GROUND WHITE BLACK BLACK HOT WHITE THERMOSTAT HIGH LIMIT CONTROL NEUTRAL FUSED DISCONNECT OR CIRCUIT BREAKER WIRING NO 1 SINGLE ELEMENT HE...

Отзывы: