background image

F

D

3" VENT

11.5" MIN.

FROM TOP OF

HEATER TO

CENTER LINE

OF FLUE

1/2" GAS

CONNECTION

B

A

E

C

4"

GPDX-50 is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
GPD-75 is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.
Recovery capacity based on actual performance tests.
Water connections, 3/4" on all models.

Propane inputs/recoveries: GPD-40: 36,000BTU/37GPH

GPD-50: 38,000BTU/39GPH
GPDX-50: 60,000BTU/59GPH
GPD-75: 65,000BTU/67GPH

*R Value shown is “performance rated.”

MODEL

NUMBER

FIRST

HOUR

RATING

GALLONS

ENERGY

FACTOR

GAL.

CAP.

BTU

INPUT

PER HOUR

NATURAL

RECOVERY

90ºF RISE

GALLONS

PER HOUR

R

VALUE*

A

B

C

D

E

F

BLOWER

OUTLET

APPROX.

SHIPPING

WEIGHT

(LBS)

GPD-40

70

.60

40

40,000

41

16

57

48-1/2

21

15

8

42

3

224

GPD-50

87

.59

50

40,000

41

16

66

57-1/2

21

15

8

51

3

232

GPDX-50

105

.58

50

65,000

64

16

69-1/2

61

21

15

8

54-1/2

3

232

GPD-75

130

.58

75

70,000

72

16

71-1/2 61-1/2 26-1/4 15-1/2

8

54-3/4

3

300

DIMENSIONS IN INCHES

IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS

Read and follow requirements shown in the Installation Manual for ProMax

®

Power Direct-Vent Gas water heaters dealing with type, placement and length
of vent pipe and vent termination, as well as clearances required to provide
adequate combustion and proper ventilation.

IMPORTANT:
SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER
HEATERS

OPTIONAL (DELUXE) ROUND HORIZONTAL
VENT TERMINATION KIT

Part Number 9002749005

OPTIONAL (DELUXE) SQUARE HORIZONTAL
VENT TERMINATION KIT

Part Number 9003328005

Maximum hydrostatic working pressure: 150 psi

www.hotwater.com

For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.