PRODUCT PARAMETER
Trade mark:
A.O. Smith
Country of origin:
China
Manufacturers No.:
MEV/MEH
Rated Voltage:
220~240Volt 50/60Hz
Rated input : 1200-1400W /1500-1800W
/2000-2400W/2500-2750W
(See Product label)
Rated working pressure: 600 kPa (6 bar)
Pressure relieve valve: 700 kPa (7 bar)
Top pressure relieve valve: 800 kPa (8 bar)
The Test Pressure:
1600kPa (16 bar)
Max. Thermostat setting: 75
℃
Thermal cut-out:
87
℃
For safety purposes it is recommended to connect the water heater to the power supply
via a suitable double-pole switch, preferably provided with fuses.
Remove the cover at the bottom to access the electrical connections.
Connect the ground conductor to the ground connection (5).
Connect the other two conductors to L and N.
Replace bottom cover.
LEGEND
1)
Thermometer
2)
Heating element
3)
Anode
4)
Cold water inlet pipe with diffuser
5)
Hot water outlet pipe
6)
Control thermostat and thermal cut-out reset button
7)
Combination pressure relieve/check valve
8)
Additional top pressure relieve valve
9)
Stop cock (not included with water heater)
10) Pilot light
11) Blue ring
12) Red ring
MODELS: MEV 50/80/100
1
2
3
4
5
6
A.O.S
7
9
10
11
12
15
14
17
16
1-Thermostat setting knob
2-Pilot light
3-Thermal cut-out reset knob
4-Power supply connection
5-Ground connection
6-Heating element
A
DIVISION
OF A.O. SMITH
CORPORATION
ELECTRICAL CONNECTION
A.O. Smith Water Products Company B.V., De Run 5503 LW Veldhoven
,
PO Box 70 NL –5500
AB Veldhoven
,
Netherlands
Tel. +31 40 294 25 00 Fax. +31 40 294 25 09
E-Mail:[email protected]. Internet: www.aosmithme.com
MODELS: MEH 50/80/100
PN:407703-005 REV.20190509