background image

MODEL

NUMBER

A

B

C

D

E

F

G

H

GAS

CONN.

WATER

CONN.

APPROX.

SHIPPING

WEIGHT

(LBS.)

BTR-151

and

BTR-201

inches

45

40

27-3/4

32-1/4

15-3/4

5

6-1/2

6

3/4

1-1/2

460

cm

114.3

101.6

70.5

81.9

40

12.7

16.5

15.2

-

-

181.8

B

E

F

C

D

H

G

A

1 1/2" NPI

OUTLET

1 1/2" NPI

INLET

CLEARANCE

1" NPI RELIEF

VALVE OPENING

15.2cm

1.5

3.8cm

Commercial Gas Water Heaters

BOOSTER MODELS

SUGGESTED SPECIFICATION

Gas booster water heater(s) shall be A.O. Smith Master-Fit, Model Number ___________________ , with a 32-gallon storage
capacity, an input rate of __________________ BTU/HR, _________________ gas, and a recovery rate of ________ gallons
per hour at a ________ degree Fahrenheit temperature rise, and a maximum hydrostatic working pressure of 160 psi.

Unit(s) shall have a fan-assisted combustion system, providing a power-induced draft of makeup air prior to burner ignition.
Unit(s) shall be equipped with intermittent electronic ignition with power on/off switch, which shall provide flame failure
response in less than one second. The burner for the unit(s) shall be easily removable. Unit(s) shall be equipped with a 
factory-installed temperature and pressure relief valve, and a 2-3/4'' x 3-3/4'' tank inspection port.

The water heater tank shall be glasslined and protected against premature failure in the following ways:

1. Against electrolytic corrosion by multiple, factory-installed anode rods

2. Against failure due to overheating caused by the buildup of scale, film and other sediment by a self-cleaning device, 

positioned inside the tank so that it directs the flow of inlet water in such a way that microscopic particles of precipitated 
solids shall be kept in suspension and exhausted from the water heater on that or successive hot water draws.

Unit(s) shall meet or exceed ASHRAE/IESNA 90.1-1999, and be design certified by UL (Underwriters Laboratories), according
to ANSZ21.10.3-CSA4.3 standards governing storage-type water heaters.

MODEL

NUMBER

BTU

INPUT

PER

HOUR

Gallons

or

Litres

TANK

SIZE

FIRST

HOUR

RATING

GPH

or

LPH

40°F

22°C

60°F

33°C

80°F

44°C

100°F

56°C

140°F

78°C

BTR-151 150,000

U.S.Gallons

32

167

GPH

364

242

182

145

104

Litres

121.1

632.1

LPH

1377.7 916 688.9 548.8 393.6

BTR-201 199,000

U.S.Gallons

32

216

GPH

485

322

241

194

139

Litres

121.1

817.6

LPH

1835.7 1218.8 912.2 734.3 526.1

RECOVERY – GALLONS or LITRES

PER HOUR AT DEGREE RISE

DIMENSIONS AND WEIGHT

CAPACITY, INPUT AND OUTPUT

DIMENSIONS

500 Tennesse Waltz Parkway, Ashland City, TN 37015

For Technical Information and Automated Fax Service, call 800-527-1953.

A.O. Smith reserves the right to make product changes or improvements without prior notice.

Printed in U.S.A.

ACGSS00705

www.hotwater.com