0312734_ITS_400-1000_NLENFR_V4.0, 2019-03-08
31
3
Filling and draining
Note
These products can be installed as vented and unvented. This manual only
discusses unvented installations. For information about vented installations please
contact A.O. Smith.
Legend
1. pressure relief valve
(mandatory if mains water
pressure is too high)
3. T&P-valve
4. stop valve (recommended)
5. non-return valve
(mandatory)
6. circulation pump (optional)
9. drain valve
11. service stop valve
12. temperature gauge
(optional)
14. draw-off points
15. expansion valve
(mandatory)
16. expansion vessel
(mandatory)
A. cold water supply
B. hot water supply
C. circulation pipe
F. inlet heat exchanger
G. outlet heat exchanger
Installation Diagram
IMD-0451 R1.0
3.1 Filling
To fill the water heater, proceed as follows:
1. Open the stop valve (11) in the hot water pipe and, if present, the stop valves (4)
for the circulation pump (6).
2. Close the drain valve (9).
3. Open the nearest hot water draw-off point (14).
4. Open the stop valve (4) on the cold water side (A) so that cold water flows into
the water heater.
5. Completely fill the water heater. When a full water jet flows from the nearest
draw-off point, the water heater is full.
6. Bleed the entire installation of air, for example by opening all draw-off points.
7. The water heater is now under water supply pressure. There should now be no
water coming out of the inlet combination expansion valve or (if used) out of the
T&P valve (3). If there is, the cause might be:
-
The water supply pressure is greater than the specified value (1.6 "General
specifications"). Rectify this by fitting a pressure reducing valve (1).
-
The expansion valve in the protected cold supply set-up is defective or
incorrectly fitted.
Содержание ITS 1000
Страница 4: ...Installatie Service en Gebruikershandleiding 4 ...
Страница 6: ...Installatie Service en Gebruikershandleiding 6 ...
Страница 8: ...Installatie Service en Gebruikershandleiding 8 ...
Страница 11: ...0312734_ITS_400 1000_NLENFR_V4 0 2019 03 08 11 Doorsnede vooraanzicht toestel IMD 1294 R0 0 ...
Страница 12: ...Installatie Service en Gebruikershandleiding 12 ...
Страница 22: ...Installation Service and User Manual 22 ...
Страница 24: ...Installation Service and User Manual 24 ...
Страница 28: ...Installation Service and User Manual 28 ...
Страница 38: ...Notice d installation Mode d emploi Notice d entretien 38 ...
Страница 40: ...Notice d installation Mode d emploi Notice d entretien 40 ...
Страница 44: ...Notice d installation Mode d emploi Notice d entretien 44 ...