background image

ITE

Technical specifications

ITE 400

 

ITE 500

 

ITE 600

 

ITE 750

 

ITE 1000

Technical data

                        

Output coil 

kW 

 

52 

68 

72 

80 

87

Surface area coil 

m

2

 

 

2.45 

3.11 

3.45 

3.72 

4.82

Water capacity coil 

 

14.8 

18.8 

29.3 

31.6 

40.9

Flow rate coil  (80-60°C) 

l/h 

 

2236 

2924 

3096 

3440 

3741

Pressure drop coil 

mbar 

 

244 

489 

104 

128 

259

Maximum working pressure tank 

bar 

 

10 

10 

10 

10 

10

Maximum working pressure coil 

bar 

 

16 

16 

16 

16 

16

Maximum operating temperature tank 

°C 

 

95 

95 

95 

95 

95

Maximum operating temperature coil 

°C 

 

110 

110 

110 

110 

110

Standby loss 

kWh/24h 

 

1.60 

1.88 

1.85 

2.03 

2.19

Anodes 

 

1

Maximum weight 

kg 

 

520 

657 

881 

971 

1338

                          

Draw-off capacity 

                        

Storage capacity 

 

389 

478 

652 

734 

1024

30 min. 

T=44°C 

 

882 

1120 

1345 

1504 

1882

60 min. 

T=44°C 

 

1390 

1784 

2048 

2286 

2733

90 min. 

T=44°C 

 

1898 

2449 

2752 

3068 

3583

120 min. 

T=44°C 

 

2406 

3113 

3455 

3856 

4433

Continuous 

T=44°C 

l/h 

 

899 

1525 

1955 

2033 

2189

Heating-up time 

T=44°C 

min. 

 

20 

15 

15 

19 

20

30 min. 

T=50°C 

 

776 

985 

1183 

1324 

1656

60 min. 

T=50°C 

 

1223 

1570 

1802 

2012 

2405

90 min. 

T=50°C 

 

1670 

2155 

2422 

2700 

3153

120 min. 

T=50°C 

 

2118 

2740 

3041 

3388 

3901

Continuous 

T=50°C 

l/h 

 

791 

1342 

1720 

1789 

1926

Heating-up time 

T=50°C 

min. 

 

22 

17 

16 

22 

23

30 min. 

T=55°C 

 

705 

896 

1076 

1203 

1506

60 min. 

T=55°C 

 

1112 

1427 

1639 

1829 

2186

90 min. 

T=55°C 

 

1518 

1959 

2201 

2454 

2866

120 min. 

T=55°C 

 

1925 

2491 

2764 

3080 

3546

Continuous 

T=55°C 

l/h 

 

719 

1220 

1564 

1626 

1751

Heating-up time 

T=55°C 

min. 

 

25 

19 

18 

24 

25

                          

Shipping data   

                      

Weight empty 

kg 

 

131 

179 

229 

237 

314

Weight incl. packaging 

kg 

 

153 

201 

251 

260 

348

Width packaging 

mm 

 

780 

780 

870 

870 

1010

Height packaging 

mm 

 

1850 

2150 

1930 

2150 

2100

Depth packaging 

mm 

 

780 

780 

870 

870 

1010

Содержание ITE

Страница 1: ...Insulated ring base Insulated access cover for comprehensive waterside maintenance Replaceable magnesium anode Options Flexible magnesium anode for installation in confined areas Powered anode for reduced maintenance requirements Temperature and pressure valve with stainless steel spring set to 95 C and a maximum water pressure of 7 bar Analogue temperature gauge 0 120 C Electric element heat packs...

Страница 2: ...4 C l 1390 1784 2048 2286 2733 90 min T 44 C l 1898 2449 2752 3068 3583 120 min T 44 C l 2406 3113 3455 3856 4433 Continuous T 44 C l h 899 1525 1955 2033 2189 Heating up time T 44 C min 20 15 15 19 20 30 min T 50 C l 776 985 1183 1324 1656 60 min T 50 C l 1223 1570 1802 2012 2405 90 min T 50 C l 1670 2155 2422 2700 3153 120 min T 50 C l 2118 2740 3041 3388 3901 Continuous T 50 C l h 791 1342 1720...

Страница 3: ...476 1627 1602 U 1 Cold water R2 R2 R21 2 R21 2 R21 2 2 Hot water R2 R2 R21 2 R21 2 R21 2 3 Inlet coil Rp1 Rp1 Rp1 Rp11 4 Rp11 4 4 Outlet coil Rp1 Rp1 Rp1 Rp11 4 Rp11 4 7 Connection Rp3 4 Rp3 4 Rp3 4 Rp3 4 Rp3 4 8 Anode connection Rp11 4 Rp11 4 Rp11 4 Rp11 4 Rp11 4 8 Connection female 1 111 2 npt 1 111 2 npt 1 111 2 npt 1 111 2 npt 1 111 2 npt 10 Anode connection Dimensions in mm All ITE calorifier...

Страница 4: ... 11 Isolating valve 12 Temperature gauge 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A Cold water B Hot water C Return circulation F Primary flow G Primary return E Over flow pipe H Expansion vent pipe A O Smith unvented system kits utilise combination valves Further installation and connection details can be found in the Insta...

Отзывы: