background image

Warranty Card (Company Copy)

(To be sent back to the Company)     Unit Serial Number:

Dealer’s Stamp and Signature 

Invoice Number:                                                    Dated:

Customer's Name and Address: 

Model:                           Capacity: 

Warranty Card

Warranty Card (Customer Copy)

(To be retained by the Customer)      Unit Serial Number:

Dealer’s Stamp and Signature 

Invoice Number:                                                    Dated:

Customer's Name and Address: 

Model:                           Capacity: 

Warranty Card

10

Содержание HSE-SAS

Страница 1: ...lity that ensures you have a water heater that works in Indian water conditions Guaranteed A O Smith Service within 24 hours Call 1 800 103 2468 ADVANCED TECHNOLOGY SUPERIOR QUALITY EXPERT SERVICE BEE 4 star rating Saves time saves energy saves money ENERGY SAVING Made in India s most modern and advanced water heater factory MADE BETTER Why people prefer an A O Smith water heater ...

Страница 2: ...from any phone anywhere in the country to our Toll Free Customer Care No 1 800 103 2468 Or Factory Address A O Smith India Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India About A O Smith A O Smith India Water Heating Private Limited was established in 2006 Since then the A O Smith team has conducted nume...

Страница 3: ...r Guide Conditio ns Apply Water Heater HSE SAS 6 10 15 25 Litres Fitit Forgetit Blue Diamond glass lined tank Maximum protectio n against hard water and corrosion Get the best quality that ensures you have a water heater that works in Indian water condition s Guarante ed A O Smith Service within 24 hours Call 1 800 10 3 2468 ADVAN CED TECHNO LOGY SUPERI OR QUALIT Y EXPERT SERVIC E BEE 4 star ratin...

Страница 4: ...ge Frequency V Hz 230 50 230 50 230 50 230 50 Actual Stdg Loss kWh 24h 45 C diff 0 412 0 515 0 592 0 721 o Max Stdg Loss kWh 24h 45 C diff as per IS 2082 1993 amended in 2002 0 792 0 990 1 138 1 386 Reheating Time for 35 C rise in min 6 11 18 29 Temperature range C 25 75 25 75 25 75 25 75 2 N cm 80 80 80 80 Water head metres 80 80 80 80 Inlet Outlet connections Inch Rated water pressure 12 11 10 9...

Страница 5: ...ge water in case the pressure overshoots the preset limits Safety Valve If the water temperature exceeds the highest preset level the breaker rapidly cuts off the live line and the neutral line simultaneously to assure safety Thermal Cutout HI G H MEDIUM L OW Temperature Control Knob The temperature control knob allows you to set the temperature precisely between 25 C to 75 C The tank has an anode...

Страница 6: ... be 120mm and the vertical distance should be 57mm Fig 2 4 Insert the expansion anchors into the holes Place the wall mounting bracket over the expansion anchors and tighten the screws on the bracket Fig 3 5 Place the water heater on wall mounting bracket Fig 4 using hanger hooks Tug downwards on the heater to ensure that the water heater is fixed steadily Wall Fig 3 Installation of wall mounting ...

Страница 7: ...tube should be installed downwards without any loops folds or knots Ensure that the free end of the discharge tube is placed over a suitable drain and away from the users Discharge tube is provided to release the discharge from the water heater through the safety valve in case excessive pressure is developed The contents of the discharge from the Safety valve may be hot and may cause burns to the ...

Страница 8: ...ring repair or periodic maintenance if necessary the power cord or Internal electrical wiring should be replaced by A O Smith Authorised service personnel only It is not permitted for the power supply plug and cord to be replaced or altered by unauthorised people or by the users themselves This will make the warranty null and void and may cause the water heater operation hazardous Directions for u...

Страница 9: ...lour You have the option of changing this panel to match your bathroom décor at a nominal cost Pull out the Knob Please follow the instructions as shown in Fig 8 Changing the Decorative Front Panel Unscrew Remove the Decorative Front Panel to change Warning Please ensure to switch off the power supply while changing the Decorative Front Panel and pull out the power plug from the socket An insulati...

Страница 10: ...mer Care Centre wiring error Green light on Non functioning Call Customer Care Centre Red light off thermostat No hot water Control circuit or internal wiring error Water temperature Thermostat set is too high Call Customer Care Centre is too high Thermal cutout trips Call Customer Care Centre Water heats slowly Non functioning element Call Customer Care Centre Thermostat does Non functioning Call...

Страница 11: ...rried out or certifying working of the goods thereafter 4 The Company or its Authorised service provider will be entitled to retain any defective part replaced under the warranty 5 The Company s liability under the warranty will be limited only to defects which occur under conditions of proper installation normal operation and under proper use It excludes defects occurring because of abuse faulty ...

Страница 12: ...vice Contract he has the option of calling our Authorised service provider and having his A O Smith Water Heater unit serviced on actual basis i e by paying the Labour Cost and Spares needed to attend to that Service or Complaint Call at the prevailing Company rates Such service will be rendered by the Company in towns or places where the Company has its Authorised service providers 3 In case of p...

Страница 13: ... Stamp and Signature Invoice Number Dated Customer s Name and Address Model Capacity Warranty Card Warranty Card Customer Copy To be retained by the Customer Unit Serial Number Dealer s Stamp and Signature Invoice Number Dated Customer s Name and Address Model Capacity Warranty Card 10 ...

Страница 14: ...rea Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India Toll Free No 1 800 103 2468 Website www aosmithindia com 11 Regional Office Delhi 105 106 Plot No 19 Sagar Plaza Laxmi Nagar District Centre Vikas Marg Laxmi Nagar New Delhi 110 092 Kolkata 224 A Office No 811 8th Floor Krishna Building AJC Bose Road Kolkata 700 017 Mumbai Sanjar Enclave No 509 CTS No 428 S V Road Opp Milap...

Страница 15: ......

Страница 16: ... Water Heating Private Limited Plot No 300 Phase 2 KIADB Industrial Area Harohalli Kanakapura Taluk Ramanagara District 562 112 Karnataka India Toll Free 1 800 103 2468 Website www aosmithindia com Part No 322858 000_R1 Dt 19 04 2013 ...

Отзывы: