ElECtrICal data

GEnEral

Check the water heater model and rating plate information against 

the  characteristics  of  the  branch  circuit  electrical  supply.  Do  not 

connect the heater to an improper source of electricity. 

Voltage applied to the water heater should not vary more than +5% to 

-10% of the model and rating plate marking for satisfactory operation.

Do NOT energize the branch circuit for any reason before the water 

heater  tank  is  filled  with  water.  Doing  so  may  cause  the  heating 

elements to fail.

The  installation  must  conform  to  these  instructions  and  the  local 

code  authority  having  jurisdiction.  Grounding  and  electrical  wiring 

connected  to  the  water  heater  must  also  conform  to  the  National 

Electrical  Code,  NFPA  70.  This  publication  is  available  from  The 

National Fire Protection Association, 1 Batterymarch Park, Quincy, 

MA 02269.

BranCh CIrCuIt

The branch circuit wire size should be established through reference 

to  the  NEC  (National  Electrical  Code)  or  other  locally  approved 

sources in conjunction with the water heater amperage rating.. Wire 

rated at 75°C should be used. For convenience, portions of the wire 

size tables from the Code are reproduced in Table 1 on page 9. It 

is suggested the electrician size the branch circuit at 125 percent 

of the heater rating and further increase wire size as necessary to 

compensate for voltage drop in long runs. Voltage drop should not 

exceed 3% at the water heater.

hEatEr CIrCuIts

The water heater’s electrical components are pictured and identified 

in the Features and Components illustrations in Diagrams 1 and 2. 

The model and rating plate provides heater circuit ratings. There are 

two main electrical circuits:

Control  Circuit:

  Power  supply  for  the  electromagnetic 

contactor coils. 120V power is supplied to the contactor coils 

by  the  CCB  (Central  Control  Board)  see  wiring  diagrams  in 

this manual.

Power  Circuit:

  High  voltage,  single  or  three  phase,  circuit  that 

carries the heating element load.

The following section and pages describe the water heater circuits 

and includes wiring diagrams. 

Control CIrCuIts

The water heater is equipped with an electronic control system. The 

system  includes  a  CCB  (Central  Control  Board)  circuit  board,  an 

immersion temperature probe with ECO for temperature sensing and 

limiting, a UIM (User Interface Module) for user interface & information 

display and element current sensors for monitoring the power circuits. 

Refer to the control circuit label on the water heater for details. The 

CCB is powered by a small 120V/24V transformer. The control circuit 

operates on 120V supplied by a larger 100VA transformer.

sequence of operation

1.  When  the  control  is  powered,  the  UIM  should  display  model 

information,  water  temperature,  operating  setpoint,  heating 

status and operating mode.

2.  If the control determines that the actual water temperature inside 

the tank is below the programmed operating setpoint minus the 

(1st) differential setpoint, a call for heat is activated.

3.  After  all  safety  checks  are  verified  the  CCB  will  energize  the 

contactor  coil(s).  On  models  with  more  than  one  heating 

element the upper most heating elements are energized first. 

Successive  heating  elements  are  energized  according  to 

programmed differential setpoints for each heating element.

4.  The  control  remains  in  the  heating  mode  until  the  water 

temperature  reaches  the  programmed  operating  setpoint.  At 

this point the contactors will be de-energized.

5.  The  control  system  now  enters  the  standby  operating  mode 

while continuing to monitor the water temperature and the state 

of other system devices. If the water temperature drops below 

the programmed Operating Setpoint minus the (1st) differential 

setpoint, the control will automatically return to step 2 and repeat 

the heating cycle.

powEr CIrCuIt

Power  circuit  wiring  is  type THHN  (or  equivalent)  rated  600  volts, 

105°C, sized as necessary.

The following wiring diagrams on page 6 are included in this manual 

to show typical arrangements of electrical components in the control 

and power circuits by voltage and phase characteristics. They are to 

be used as a reference by the installer or servicer in performing their 

work. An actual diagram of the water heater wiring is furnished with 

the water heater.

Содержание DVE-10.000

Страница 1: ...Manual place these instructions adjacent to heater and notify owner to keep for future reference COMMERCIAL ELECTRIC WATER HEATER MODELS DVE 150 THRU DVE 10000 DHE 200 THRU DVE 10000 UP TO 150KW A DI...

Страница 2: ...about the type of hazard what can happen if you do not follow the safety message and how to avoid the risk of injury The California Safe Drinking Water and Toxic Enforcement Act requires the Governor...

Страница 3: ...perly may also cause erratic control system operation on ELECTRONIC CONTROL models This water heater must be connected to a grounded metal permanent wiring system or an equipment grounding conductor m...

Страница 4: ...DIAGRAMS Be sure to turn off power when working on or near the electrical system of the water heater Never touch electrical components with wet hands or when standing in water When replacing fuses al...

Страница 5: ...ter circuits and includes wiring diagrams Control Circuits The water heater is equipped with an electronic control system The system includes a CCB Central Control Board circuit board an immersion tem...

Страница 6: ...C1 C5 C4 C3 C2 C1 N GRN GRN BLK BLK X FMR ECO TEMP 120V BLK BLU RED RED RED RED SDI 24V X FMR PRIMARY FUSES X FMR 120V SEC SEC FUSE PILOT SWITCH BLK BLK JUMPER TO DISPLAY LWCO 5 4 3 2 1 FUSES CNTCTR...

Страница 7: ...m Never allow small children to use a hot water tap or draw their own bath water Never leave a child or disabled person unattended in a bathtub or shower The water heater should be located in an area...

Страница 8: ...irectly above each button on the LCD screen The function will change depending on what menu is currently displayed or what menu item is selected When no text appears on the LCD screen above an Operati...

Страница 9: ...used the fault is corrected Power to the water heater must be cycled off and on to reset the control system Note cycling power will not reset the control system if the condition that caused the fault...

Страница 10: ...peration total heating cycle time heating cycle count heating element s cycle count and on time along with UIM and CCB software revisions can be viewed in this menu Current Fault Alert Displays any cu...

Страница 11: ...d with 3 heating elements with an Operating Set Point of 120 F and all Differential settings at 2 F the On Off sequencing of heating elements would be as follows ELEMENT NUMBER DIFFERENTIAL SETTING TU...

Страница 12: ...eratures is not selected use the Up and Down buttons to select this menu item With the Operating Set Point selected highlighted in black in the Temperatures Menu press the Operational Button underneat...

Страница 13: ...ontacts on the external control per all applicable building codes This is a switching circuit only DO NOT apply any external voltage or connect any load IE relay coil to either circuit Element On Disp...

Страница 14: ...or not Daily Operating Mode Sun Mon Tue Wed Thu Fri Sat Seven daily sub menus are listed at the bottom of the Economy Mode Setup menu There are 3 Operating Modes in each sub menu Normal Operation All...

Страница 15: ...ss the Operational Button underneath CHANGE to activate the adjustment mode for the Setpoint Adjustment value Use the Up Down buttons to change the Setpoint Adjustment to the desired value The Setpoin...

Страница 16: ...s to ACCEPT CANCEL when the adjustment mode is activated and how the current setting is outlined rather than highlighted in black Press the Operational Button underneath ACCEPT to enter and confirm th...

Страница 17: ...E buttons to enter the Mon sub menu as described above Use the Up Down buttons to select highlight in black the Normal Operation Between setting Press the Operational Button underneath SELECT to chang...

Страница 18: ...ternal notification when current tank temperature drops below programmable Alarm SP Fault or Alert Used for external notification whenever a Fault or Alert condition is active Fault Used for notificat...

Страница 19: ...menu displays non adjustable operational information The control system records and stores the last 9 Fault and Alert messages in chronological order in this menu The most recent will be at the top o...

Страница 20: ...actory Defaults ACTION DISPLAY From the Main Menu use the Up Down buttons to select highlight in black the Restore Factory Defaults menu Press the Operational Button underneath SELECT The Restore Fact...

Страница 21: ...e sounds are normal however the tank bottom and elements should be cleaned Refer to MAINTENANCE section of this manual for details 2 Some of the electrical components of the water heater make sounds w...

Страница 22: ...A DIVISION OF A O SMITH CORPORATION RENTON WASHINGTON Technical Support 800 527 1953 Parts Department 800 433 2515 www hotwater com...

Отзывы: