18
Status:
The Operating State of the control system is displayed
beneath the Operating Set Point.
fIGure 5.
Menu:
The left Operational Button is pressed to enter the Main Menu
where all control system menus are accessed. See Table 3 for a list
of control system menus.
Help:
The right Operational Button is pressed to access instructions
and explanations for user settings, Operating States, Status Icons,
manufacturer’s web address, technical support phone number and
service agent contact information.
Day/Time/Operating Mode:
The current time and day are also
displayed on the Desktop Screen. “Clock Not Set” will be displayed
until the time clock has been initially set. Day and Time are adjusted
in the Economy Mode Setup menu. The current Operating Mode,
either Normal Mode or Economy Mode, is displayed beneath the
day and time.
Discreet Menu Contact Information:
From the Desktop Screen
press and hold down the middle (unmarked) Operational Button for
30 seconds and then release it. This will launch a discreet menu
where personalized contact information can be entered. Installing
contractors and/or service agents can enter their company name
and telephone number. This contact information will be displayed
with all Fault and Alert messages.
taBle 3 status Icons.
Icon
descrIptIon
Water temperature in the tank has fallen. Shaded area of the animated thermometer icon will rise and fall in response to
water temperature in the storage tank as sensed from the immersion Temperature Probe.
Water temperature in the tank has reached the Operating Set Point. Shaded area of the animated thermometer icon will rise
and fall in response to water temperature in the storage tank as sensed from the immersion Temperature Probe.
The control is unable to initiate a heating cycle. This will happen whenever a Fault condition is detected by the control system
or when either of the two Enable/Disable circuits are open circuits.
The control system is in Heating Mode and has energized the electromagnetic contactor coils for at least one heating
element. This animated icon DOES NOT indicate current has been sensed from the heating elements, only that there is a
call for heat present and the control system has initiated heating element operation.
Heating element icon for a water heater equipped with 1 heating element. Open circles represent elements the control
system has not energized and IS NOT sensing electrical current flow from.
Heating element icon for a water heater equipped with 2 heating elements. Each circle represents one element. Open circles
represent elements the control system has not energized and IS NOT sensing electrical current flow from. Filled circles
represent elements the control system has energized and IS sensing electrical current flow from.
Heating element icon for a water heater equipped with 3 heating elements. Each circle represents one element. Filled circles
represent elements the control system has energized and IS sensing electrical current flow from.
Heating element icon for a water heater equipped with 4 heating elements. Each circle represents one element. Open circles
with an X represent elements the control system has energized that it IS NOT sensing electrical current flow from.
Heating element icon for a water heater equipped with 5 heating elements. Each circle represents one element. Open circles
represent elements the control system has not energized and IS NOT sensing electrical current flow from. Filled circles
represent elements the control system has energized and IS sensing electrical current flow from.
The control has detected/declared a Fault Condition. Fault message details can be viewed in the Current Fault menu.
Heating operation is discontinued (locked out) until the condition that caused the fault is corrected. Power to the water heater
must be cycled off and on to reset the control system. Note; cycling power will not reset the control system if the condition
that caused the fault has not been corrected.
The control has detected/declared an Alert Condition. The water heater will continue to operate during an Alert Condition but
there is an operational condition that requires the attention of a Qualified Service Agent. Alert message details can be viewed
in the Current Alert menu.