Servicing should only be performed by a Qualified Service Agent
21
OPERATION & SERVICE
Three Phase Delta Wiring - 4 Pole Contactor
The illustrations below show how six wire heating elements (page 17) are wired to 4 pole
contactors on water heaters connected to a three phase power supply. See the “Contactors”
section of this manual - pages 34 - 38.
Heating Element Flange - End View
Two ends
of loop 1
Two ends
of loop 2
Two ends
of loop 3
Connection Diagram
Wiring Diagram
4 Pole
Contactor
Three loops
of one heating element
Three phase (3Ø)
Models configured for
power supply
three phase power (3Ø)
and equipped with 4 pole
contactors will have a
jumper wire between the
2nd and 3rd poles of
the contactor.