CYCLONE Xi COMMERCIAL GAS WATER HEATER
BTH 120 thru 500 SERVICE HANDBOOK
A.O. Smith – Technical Training Department
3
Ashland City, Tennessee © 200
9
Servicing should only be performed by a Qualified Service Agent
316586-000
TOOLS REQUIRED
●
ELECTRICAL MULTIMETER CAPABLE OF MEASURING CONTINUITY/ OHMS, AC
& DC VOLTS, AMPERES, MICROAMPERES, MILLIVOLTS, and FREQUENCY(Hz)
○
UEi Model DL289 or equivalent
●
DIGITAL MAN 60” W. C. in .01” increments
Note: A digital manometer is required for testing pressure switches and can replace
a gas pressure gauge, draft gauge or slack tube manometer for checking gas
pressure.
○
UEi model EM200 or equivalent
●
WATER PRESSURE GAUGE w/ LAZY HAND AND HOSE BIBB CONNECTION
●
THERMOMETER
●
1-1/16 INCH SOCKET WITH EXTENSION FOR ANODE REPLACEMENT
●
SET OF NUMBERED DRILL BITS
DIGITAL MANOMETER
DIGITAL MULTIMETER
WATER PRESSURE
TEST GAUGE W/ LAZY
HAND AND HOSE BIBB
CONNECTION