A.O. Smith BTI 80 Скачать руководство пользователя страница 12

12

1. Provide complete combustion of gas.
2. Cause rapid ignition and carryover of flame across entire burner.
3. Give reasonably quiet operation during ignition, burning and extinction.
4. Cause no excessive lifting of flames from burner ports.

If preceding burner characteristics are not evident, check for accumulation
of lint or other foreign material that restricts or blocks the air openings to the
heater or burner.

  WARNING

SOOT BUILD-UP INDICATES A PROBLEM THAT REQUIRES CORRECTION
BEFORE FURTHER USE. CONSULT WITH A QUALIFIED SERVICE TECHNICIAN.

Should the main burner or burner air openings require cleaning, remove the
burner and clean with a soft brush.  Clean main burner orifice with a
suitable soft material.

CHECK FOR GOOD FLOW OF COMBUSTION AND VENTILATING AIR TO THE
UNIT.  MAINTAIN A CLEAR OPEN AREA AROUND THE HEATER AT ALL TIMES.
DO NOT STORE COMBUSTIBLES OR FLAMMABLE LIQUIDS NEAR OR
AROUND AN APPLIANCE.

CHECKING GAS INPUT

For appliance installation locations with elevation above 2000  ft.(610m)
refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input
reduction procedure.

With this heater in operation, determine whether it is receiving the full rated
input of gas.  This may be done by timing the gas meter and measuring gas
pressure with a gauge or manometer.  When the heater is operating at full
capacity (full gas input) it should consume approximately 1 cubic foot of gas
in the time shown in table 6.

TABLE 6

INPUT CHECK TIME REQUIRED TO

 

CONSUME 1 CU. FT. OF GAS

Type of

BTU Per

Time Required To Consume

Model

Gas

Cu. Ft.

1 Cu. Ft. of Gas

BTI-80

Natural

1050

47.3 sec.

BTI-100

Natural

1050

37.8 sec.

Use this formula to “clock” the meter.  Be sure that other gas consuming
appliances are not operating during this interval.

3,600  X  H  =  Btuh
   T
T  =  Time in seconds needed to burn one cubic foot of gas.

H = Heating value of gas in Btu’s per cubic foot of gas.

Btuh = Actual heater input rate.

Example: (Using BTI-80 heater)

T  =  47.3 seconds/ft

3

H  =  1,050 Btu/ft

3

 (natural gas)

Btuh  =  ?

3,600  X  1,050  =  80,000 Btuh (23.4Kwh)
 47.3

Compare the actual input rate to that given on the heater’s rating plate.  In the
example, the BTI-80’s full input rate should be 80,000 Btuh  (23.4 Kwh) for
natural gas.

VENT SYSTEM

Examine the venting system every 6 months for obstructions and/or
deterioration of vent piping.

6. After it has been determined that each appliance connected to the

venting system properly vents when tested as outlined above, return
doors, windows, exhaust fans, fireplace dampers and any other gas
burning appliance to their previous conditions of use.

7. If improper venting is observed during any of the above tests, the

venting system must be corrected.

 WARNING

FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR CONTAMINATION
AND UNSAFE CONDITIONS.

HIGH TEMPERATURE LIMIT SWITCH (ECO)

The water heater is equipped with a manual reset type high limit (Energy
Cutoff) sensor.  The high limit switch interrupts the main burner gas flow
should the water temperature reach 195°F (90°C).  The high limit switch
must be manually reset by turning the power to the water heater off for 5
seconds then back on and cannot be reset until the water temperature
drops below 120°F (49°C).  It is important that a serviceman be called to
determine the reason for limit operation and thus avoid repeated thermostat
resetting.

  

 WARNING

THE ON/OFF SWITCH MUST HAVE BEEN IN THE OFF POSITION FOR
AT LEAST 5 MINUTES.  This waiting period is an important safety step.
Its purpose is to permit gas that may have accumulated in the combustion
chamber to clear.  IF YOU DETECT GAS ODOR AT THE END OF THIS
PERIOD DO NOT PROCEED WITH LIGHTING. RECOGNIZE THAT GAS
ODOR, EVEN IF IT SEEMS WEAK, MAY INDICATE PRESENCE OF
ACCUMULATED GAS SOMEPLACE IN THE AREA WITH RISK OF FIRE OR
EXPLOSION.  SEE THE FRONT PAGE FOR STEPS TO BE TAKEN.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT
OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.

SERVICE INFORMATION

The installer may be able to observe and correct certain problems which
may arise when the unit is put into operation.  HOWEVER, it is recommended
that only qualified servicemen, using appropriate test equipment, be allowed
to service the heater.

FOR YOUR SAFETY AND SATISFACTORY OPERATION, IT IS
RECOMMENDED THAT THIS HEATER BE CHECKED ONCE A YEAR BY A
COMPETENT SERVICE PERSON.

USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS
WEAR OUT OVER A PERIOD OF TIME.  THE GAS CARRYING COMPONENTS
OF THIS APPLIANCE SHOULD BE INSPECTED FOR PROPER OPERATION
PERIODICALLY BY A QUALIFIED SERVICE TECHNICIAN.

MAIN BURNER AND IGNITER

Check main burner (figure 7) at least every 6 months for proper flame
characteristics.  The main burner should display the following
characteristics:

FIGURE 7-MAIN BURNER AND IGNITER ASSEMBLY - NATURAL GAS

Содержание BTI 80

Страница 1: ... MAINTENANCE LIMITED WARRANTY Thank you for buying this energy efficient water heater from A O Smith Water Products Company We appreciate your confidence in our products CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLINGAND USING THIS APPLIANCE A DIVISION OF A O SMITH CORPORATION McBEE SOUTH CAROLINA USA STRATFORD ONTARIO C...

Страница 2: ...Quincy MA02269 INSTALL IN ACCORDANCE WITH LOCAL CODES TOP VIEW TABLE 1 DIMENSIONS A B C D E F G H J K L M MODEL In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm BTI 80 66 5 16 1684 58 1 2 1486 29 5 8 753 25 3 8 645 17 1 4 438 4 102 14 356 16 406 1 1 4 32 1 25 1 2 13 11 15 16 303 BTI 100 71 1 4 1810 66 1 2 1689 30 3 4 781 26 1 2 673 17 1 4 438 4 102 14 1 2 368 16 406 1 1 4 32...

Страница 3: ... 12 13 Hot Water Odor 13 Winter Protection 13 ReplacementParts 13 PREVENTIVEMAINTENANCE 13 14 Procedure for Periodic Removal Of Lime Deposits 13 DelimingSolvents 13 Tank Cleanout Procedure 13 14 CHECKLIST 14 15 Condensation 15 Cathodic Protection Anode 15 16 Service Repair 16 TROUBLESHOOTING 16 18 LIMITEDWARRANTY 19 Spray can propellants cleaning solvents refrigerator and air conditioning refriger...

Страница 4: ...ld conversion for operation at altitudes other than that specified on the heater rating plate is not permitted The input reduction is primarily achieved by reducing the size of the main burner orifices To do this the main burner orifices require replacement with orifices sized for the particular installation elevation Correct orifice sizing and parts may be obtained fromA O Smith Water Products Co...

Страница 5: ...BLES VAPORS AND LIQUIDS DONOTOBSTRUCTTHEFLOWOFCOMBUSTIONORVENTILATINGAIR WARNING ATTICAND OREXHAUSTFANSOPERATINGONTHEPREMISESWITHA WATERHEATERCANRESULTINCARBONMONOXIDEPOISONINGAND DEATH OPERATION OF THESE FANS CAN PRODUCE A NEGATIVE DRAFT INTHEAREAOF THE WATER HEATER PREVENTING THE PRODUCTS OF COMBUSTION FROM EXHAUSTING THROUGHTHE CHIMNEY OR VENT PIPE The venting of the water heater should be insp...

Страница 6: ... system are exposed to ambient temperatures below 35 degrees F 2 degrees C it must be insulated to prevent condensation Do not connect the heater to a common vent or chimney with solid fuel burning equipment This practice is prohibited by many local building codes as is the practice of venting gas fired equipment to the duct work of ventilation systems Where a separate vent connection is not avail...

Страница 7: ...Your local code authority may have other specific relief valve requirements ADRAINLINEMUSTBECONNECTEDTOTHERELIEFVALVETODIRECT DISCHARGE TOASAFE LOCATION TOAVOID SCALDING OR WATER DAMAGE THISLINEMUSTNOTBEREDUCEDFROMTHESIZEOFTHE VALVEOUTLETANDMUSTNOTCONTAINVALVES RESTRICTIONSNOR SHOULDITBELOCATEDINFREEZINGAREAS DONOTTHREADORCAP THEENDOFTHISLINE RESTRICTEDORBLOCKEDDISCHARGEWILL DEFEATTHEPURPOSEOFTHEV...

Страница 8: ... having jurisdiction AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION If any of the original wire as supplied with the appliance must be replaced use only type 105 C thermoplastic or equivalent 250 C type F must be used for the flame sensor leads and the spark ignition cable must be high voltage 250 C CAUTION LABELALLWIRES PRIOR TO DISCONNECTION WHEN SE...

Страница 9: ...as entered CAUTION PURGINGSHOULDBEPERFORMEDBYPERSONSEXPERIENCEDINTHIS TYPEGASSERVICE TOAVOIDRISKOFFIREOREXPLOSION PURGE DISCHARGEMUSTNOTENTERCONFINEDAREASORSPACESWHERE IGNITIONCANOCCUR THEAREAMUSTBEWELLVENTILATEDANDALL SOURCESOFIGNITIONMUSTBEINACTIVATEDORREMOVED GASMETERSIZE NATURALGASESONLY Be sure the gas meter has sufficient capacity to supply the full rated gas input of the water heater as wel...

Страница 10: ... them call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS A Set thermostat to the lowest setting B Turn of...

Страница 11: ... the venting system for proper size and horizontal pitch as required in the National Fuel Gas Code ANSI Z223 1 NFPA54 or the CAN CGA B149 Installation codes and these instructions Determine that there is no blockage or restriction leakage corrosion and other deficiencies which could cause an unsafe condition 3 So far as is practical close all building doors and windows and all doors between the sp...

Страница 12: ...hs for obstructions and or deterioration of vent piping 6 After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above return doors windows exhaust fans fireplace dampers and any other gas burning appliance to their previous conditions of use 7 If improper venting is observed during any of the above tests the venting system must be c...

Страница 13: ...ontact your dealer WINTER PROTECTION In regions where freezing weather is encountered all water must be drained from unit and piping when out of service water shut off Drain valve must be left open until unit is returned to service REPLACEMENT PARTS Replacement parts may be ordered throughA O Smith dealers authorized servicers or distributors Refer to the Yellow Pages for where to call or contact ...

Страница 14: ...over under opening and install 3 4 x 4 pipe nipple Drill or punch a 3 16 vent hole in handle Astainless steel screw is included with the Flo Jug kit This screw is to be installed in the vent hole when Flo Jug is not in use Remove drain valve from heater and insert a 3 4 x 4 nipple Connect and clamp 1 I D x 3 hose to Flo Jug and heater nipple 3 Lift the Flo Jug to the POUR POSITION and permit the U...

Страница 15: ...ing the tank bottom This too can result in condensation Condensation appearing in the vent pipe water dripping from draft diverter during heater operation is evidence of poor vent action Possible causes are too long a vent pipe or improper chimney operation 3 If the leakage is from the temperature and pressure relief valve or its discharge pipe it may represent a normal condition However see RELIE...

Страница 16: ... going to our website at www hotwater com Please click on Mail then click on Service and leave us a message Please be sure to provide the following information when writing or e mailing Model Number Serial Number Date of Original Purchase Date Problem Originated Explanation of Problem Also please be sure to include a daytime telephone number TROUBLESHOOTING Water heaters may exhibit problems that ...

Страница 17: ...hermostat threads Leakage from other appliances or water lines Condensation of flue products Thermal expansion in closed water system Improperly seated valve High sulfate or mineral content in water supply or iron or sulfate reducing bacteria in water supply Turn switch to the ON position Plug blower back into 115 vac outlet Repair service to outlet Replace switch Replace control harness Replace b...

Страница 18: ...essure switch tubing not connected blower was energized correctly 3 Air intake or exhaust obstructed Error in the hot surface ignitor circuit 1 Check that all wiring is correct and secure 2 Replace hot surface ignitor System in lockout 1 Gas supply is off or too low to operate 2 Hot surface ignitor not positioned correctly 3 Low voltage to the water heater 4 Electric polarity to unit is incorrect ...

Страница 19: ...t the heater s and operational at all times The relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will provide only a replacement water heater or part thereof The owner is responsible for all other costs Such costs may include but are not limited to a Labor charges for service removal repair or reinstallation of ...

Страница 20: ...20 5621 W 115TH STREET ALSIP IL 60803 PHONE 1 800 433 2545 FAX 1 800 433 2515 www hotwater com E mail parts hotwater com REPLACEMENT PARTS ...

Отзывы: