GET TO  KNOW YOUR WATER  HEATER

 FIGURE 1

REPLACEMENT PARTS AND DELIMING PRODUCTS

Replacement parts and recommended delimer may be ordered
through authorized servicers or distributors.  Refer to the Yellow
Pages for where to call or contact A.O. Smith  Water Products
Company, 5621 W. 115th Street, Alsip, Illinois  60803, 1-800-433-
2545.  When ordering parts, provide complete model and serial
numbers (see rating plate), quantity and name of part desired (as
listed in Figure 1).  Standards hardware items may be purchased
locally.

(A)

VENT PIPE

(B)

 DRAFT HOOD

(C)  ANODE
(D)  HOT WATER

 OUTLET

(E)

 OUTLET

(F)

 INSULATION

(G)  GAS SUPPLY
(H) MANUAL GAS SHUT

 OFF VALVE

(J)

 GROUND JOINT UNION

(K)

 DIRT LEG

(L)

HINGED INNER DOOR

(M) OUTER DOOR
(N) UNION

(O) INLET WATER SHUT OFF

 VALVE

(P)

COLD WATER INLET

(Q) INLET DIP TUBE
(R) TEMPERATURE AND

PRESSURE RELIEF VALVE

(S)

RATING PLATE

(T)

FLUE BAFFLE

(U) THERMOSTAT
(V)

DRAIN VALVE

(W) PILOT AND MAIN BURNER
(X)

FLUE

(Y)

DRAIN PAN

(Z)

THERMOSTAT SHIELD
(OPTIONAL)

DIRTLEG AS
REQUIRED
BY LOCAL CODE

INSTALL THERMAL EXPANSION

TANK IF CHECK VALVE OR

PRESSURE REDUCING VALVE

IS USED IN SUPPLY

(W)
PILOT &
MAIN BURNER

Содержание AOSRG45200

Страница 1: ...OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE PART NO 183390 000 SUPERSEDES PART NO 183285 000 PRINTED IN U S A 2460...

Страница 2: ...esired as listed in Figure 1 Standards hardware items may be purchased locally A VENT PIPE B DRAFT HOOD C ANODE D HOT WATER OUTLET E OUTLET F INSULATION G GAS SUPPLY H MANUAL GAS SHUT OFF VALVE J GROU...

Страница 3: ...ing of the water heater should be inspected by a qualified service technician at the time of installation and periodically thereaf ter to ensure a down draft condition does not exist DO NOT OBSTRUCT T...

Страница 4: ...onal Fuel Gas Code ANSI Z223 1 NFPA 54 The code is available from the Canadian Standards Association 8501 East Pleasant Valley Road Cleveland OH 44131 LOCATION OF HEATER The heater is design certified...

Страница 5: ...ed water supply system Contact the water supplier or local plumbing inspector on how to correct situation Do not plug the temperature and pressure relief valve GAS CONNECTIONS The minimum gas supply p...

Страница 6: ...ew holes in the top of heater Insert the tabbed draft hood legs into the corresponding tab holes Screw the draft hood down using the included draft hood screws When installing vent piping secure the v...

Страница 7: ...in gas control knob slightly and turn clockwise to OFF SEE FIGURE A NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any g...

Страница 8: ...ER HEATER TEMPERATURE AT 120 F APPROX MARK ON FACE OFTHERMOSTAT WILL REDUCE THE RISK OF SCALDS Some states require settings at specific lower temperatures Figure 4 shows the approximate water temperat...

Страница 9: ...p in the tank It is normal for lime and scale deposits to form within the tank Such deposits will not be removed by periodic draining It is necessary to chemically delime the affected parts in water a...

Страница 10: ...xpansion tank DO NOT plug T P valve Check relief valve for proper operation DO NOT plug T P valve Drain and flush heater thoroughly then refill Chlorinate water supply Clean pilot assembly Insert ther...

Страница 11: ...mbustion chamber doors in place Any accident to the water heater or any part thereof including freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified...