background image

NEED HELP? GIVE US A CALL

 855.424.9892

The first step in setting up your appliance is determining what elements are contained in 
your water supply. Use one of the options below to determine characteristics of your water.

•  Call Your Water Provider - For municipal 

water, call your water department to 
determine the hardness and pH of your 
water supply.

•   Test Strips - Follow the instructions on  

the provided test strips. If the color on  
your test strip is between two readings,  
use the higher number. Compare the  
colors as soon as you remove them  
from your water.

•   Hardness Test - The resulting number 

gives the hardness in grains per gallon 
(gpg) and/or parts per million  
(ppm or mg/L). 

•  Water Pressure - If water is municipally 

supplied, the water pressure must be 
greater than 20 psi (1.4 bar) and less 
than 120 psi (7 bar). If water is from 
a well, the water pressure must be 
greater than 40 psi (2.8 bar) and less 
than 120 psi (7 bar).

•  Water Temperature - Not less than 40° 

F (4° C) or greater than 120° F (49° C).

•  Water Supply Flow Rate - A minimum 

of 2.0 gallons (7.6 liters) per minute 
is recommended. For the purposes of 
plumbing sizing, only the rated service 
flow rate and corresponding water 
pressure loss may be used. Prolonged 
operation of a water softener at flow 
rates exceeding the tested service flow 
rate may compromise performance.

•   pH Test - The pH number is used to rate 

the level of acidity or alkalinity of water 
soluble substances. Water should have 
a pH of 7.

•   Testing Laboratory - To ensure  

proper settings, have a sample of your 
untreated water tested for hardness, 
iron and pH. Contact the company of 
your choice, or the company below  
to conduct a test for you. 

National Testing Laboratories, Ltd. 
1-800-458-3330  
www.watercheck.com.

•  Drain - Connect water softener to an 

appropriate drain, such as a floor drain  
or washer drain that will comply with 
all local and state plumbing codes. To 
prevent back-siphoning, provide an 
adequate air gap or a siphon break. (see 
Installation Steps)

•  Power Supply - The transformer supplied 

is for a standard 110 volt, 60-cycle AC 
outlet or 220 volt, 50-cycle AC outlet for 
locations outside North America.

•  Iron - A common problem found in many 

water supplies is iron. It is important to 
know what type of and how much iron  
is in the water supply.

NOTICE: 

If the water supply contains sand, sulfur, bacteria, iron bacteria, tannins, algae, oil, acid, or other 

unusual substances, consider pretreating the water to remove these contaminants before the water supply  

enters the water softener, unless the water softener is certified to treat these contaminants.

NOTICE: 

If ferrous iron is not present in your 

water, please skip the next page.

BEFORE YOU BEGIN

6

Test Your Water

Checklist Before Installation

Содержание AO-WH-SOFT-350

Страница 1: ...NER S MANUAL Use this owner s manual to reference installation troubleshooting and filter replacement information If you need help or have a question we ve got you covered Give us a call at 855 424 98...

Страница 2: ...Owner s Manual El manual del proprietario 100238078 WHOLE HOUSE WATER SOFTENERS AO WH SOFT 350 AO WH SOFT 400T ABLANDADOR DE AGUA PARA TODA LA CASA...

Страница 3: ...water softener runs the pre filter is cleaned through a process called regeneration This process is necessary in order to clean the resin beads so that the water softener can provide your home with so...

Страница 4: ...Compensated Hardness 7 Getting Maximum Efficiency from the Appliance 8 Precautions 9 Getting to Know Your New Softener 10 Bypass Valve Overview 11 Installation 12 16 Troubleshooting 17 18 Efficiency S...

Страница 5: ...ation If any part is missing or damaged let us know by calling 855 424 9892 Do not attempt to install the softener OVERFLOW ELBOW 12V TRANSFORMER V 185 NOZZLE DRAIN LINE CONTROLLER WARNING WARNING ind...

Страница 6: ...in death or electric shock Ground Wire and Clamps Copper Pipe Only Hard Water To Outside Faucets Shut Off Valve Inlet Outlet Hot Soft Water Water Heater Cold Soft Water Electrical Outlet Drain and Ove...

Страница 7: ...ceeding the tested service flow rate may compromise performance pH Test The pH number is used to rate the level of acidity or alkalinity of water soluble substances Water should have a pH of 7 Testing...

Страница 8: ...should be filtered out before the water reaches the softener Organic Iron or Bacterial Iron Attached to other organic compounds in the water Additional treatment is needed to remove this type of iron...

Страница 9: ...te which is the active ingredient in household chlorine bleach To disinfect appliance add 4 0 fluid ounces 120 mL of chlorine bleach solution to brine well of the brine tank Brine tank should have wat...

Страница 10: ...in line DO Allow a minimum of 8 to 10 2 4 to 3 0 m of 3 4 1 9 cm pipe from the outlet of water softener to the inlet of water heater Softener Don ts DON T Install if checklist items are not compliant...

Страница 11: ...Service Position 6 Bypass Knob 7 Bypass Position 8 Safety Shutoff 9 Controller 10 Brine Line PART 1 Bypass Valve 2 Gravity Flow Connection 3 Brine Cabinet 4 Cabinet Cover 5 Drain Line Fitting 6 Contro...

Страница 12: ...knob Turn knob to the left until it hits the stop The appliance will be bypassed and all water to the home is raw untreated water To prevent untreated water from entering the home water should not be...

Страница 13: ...ines Place water softener in desired location using the system configuration diagram as a guide The diagram applies to a basement slab crawl space and outside installations For most installations inst...

Страница 14: ...waste receptacle Maintain a minimum 2 5 cm air gap between drain line and flood level rim of waste receptacle to prevent back siphoning This drain line should be the shortest distance to the suitable...

Страница 15: ...am the water softener controller in the next step Turn off all faucets Check all lines and connections for leaks If leaks are found Turn off the main water supply Turn on cold water faucet to depressu...

Страница 16: ...Alert screen Press OK button to silence beeping and return to home screen Salt Level button will be flashing ADD After salt is added to brine cabinet remember to press Salt Level button to reset salt...

Страница 17: ...ation 1 Ensure bypass valve is left in the Service position see Service Position above 2 Ensure water supply is on 3 Open inlet valve and turn on electricity to water heater For gas water heaters retu...

Страница 18: ...sition Appliance is plumbed backwards Check that appliance is plumbed correctly Extended power outage Reset the time of day and regenerate the unit Water hardness has increased Re test the water and r...

Страница 19: ...Excessive amount of water in brine cabinet Verify correct water level relative to salt setting Estimated amount of water should be 2 12 Check brine line and fittings for loose connections Intermitten...

Страница 20: ...n An efficiency rated water softener is a demand initiated regeneration softener that also complies with specific performance specifications intended to minimize the amount of regenerant brine and wat...

Страница 21: ...20 120 psi 1 4 8 3 bar 20 120 psi 1 4 8 3 bar Maximum Flow Rate to Drain During Regeneration 2 gpm 7 6 L min 2 gpm 7 6 L min Minimum Water Flow for Backwash 2 gpm 7 6 L min 2 gpm 7 6 L min Service Flo...

Страница 22: ...y Setting min gal min L 27 5 min 21 gal 27 5 min 80 L 35 min 26 gal 35 min 98 L Controller Type 2 7 monochrome touch screen 2 7 monochrome touch screen Electrical Rating 115V 60 Hz 115V 60 Hz Plumbing...

Страница 23: ...tion P O Box 1597 Johnson City TN 37605 1597 877 333 7108 3 10 YEAR What A O Smith will do We will replace the defective part of the covered product or if necessary the product with installation instr...

Страница 24: ...na el ablandador de agua el prefiltro se limpia a trav s de un proceso llamado regeneraci n Este proceso es necesario para limpiar los granos de resina de modo que el ablandador de agua pueda proporci...

Страница 25: ...27 Hierro ferroso y dureza compensada 28 C mo obtener la m xima eficacia del artefacto 29 Precauciones 30 Conociendo su nuevo ablandador 31 Informaci n general de la v lvula de derivaci n 32 Instalaci...

Страница 26: ...est da ada ll menos para avisarnos al 855 424 9892 No intente instalar el ablandador CODO DE REBOSE TRANSFORMADOR DE 12 V BOQUILLA V 185 TUBER A DE DRENAJE CONTROLADOR ADVERTENCIA ADVERTENCIA indica...

Страница 27: ...olo tuber a de cobre Agua dura hacia las llaves exteriores V lvula de cierre Entrada Salida Agua blanda caliente Calentador de agua Agua blanda fr a Tomacorriente Tuber as de drenaje y rebose AVISO No...

Страница 28: ...dad de las sustancias solubles en agua El agua debe tener un pH de 7 Laboratorio de pruebas Para garantizar los ajustes correctos solicite realizar pruebas de dureza hierro y pH en una muestra de su a...

Страница 29: ...debe filtrar antes de que el agua alcance el ablandador Hierro org nico o hierro bacteriano Adheridos a otros compuestos org nicos en el agua Se necesita tratamiento adicional para eliminar este tipo...

Страница 30: ...r el artefacto agregue 120 mL 4 0 onzas l quidas de soluci n de blanqueador con cloro al pozo del tanque de agua salada El tanque debe tener agua Tambi n puede agregarla directamente al gabinete de ag...

Страница 31: ...mo de 2 4 a 3 0 m 8 a 10 de tuber a de 1 9 cm 3 4 desde la salida del ablandador de agua hasta la entrada del calentador de agua Lo que no debe hacer con el ablandador NO instale si no se cumplen los...

Страница 32: ...sici n de derivaci n 8 Cierre de seguridad 9 Controlador 10 Tuber a de agua salada PIEZA 1 V lvula de derivaci n 2 Conexi n de flujo por gravedad 3 Gabinete de agua salada 4 Tapa del gabinete 5 Conect...

Страница 33: ...ta que llegue al tope El artefacto se derivar y toda el agua hacia la casa ser agua no potable y no tratada Para evitar que el agua no tratada ingrese a su hogar no se debe usar el agua dentro del hog...

Страница 34: ...landador con tuber as de CPVC PEX o cobre Si usa conectores de cobre no permita que el soplete para soldar derrita las roscas de pl stico de la v lvula 1 Cierre el suministro de agua 2 Abra las llaves...

Страница 35: ...tuber a de drenaje y el borde de nivel de rebose en el recept culo de desechos para evitar el sifonaje de aguas residuales al agua de suministro La tuber a de drenaje deber a estar lo m s cerca posib...

Страница 36: ...el ablandador de agua en el siguiente paso Cierre todas las llaves Revise si hay fugas en todas las tuber as y conexiones Si se encuentran fugas Cierre el suministro principal de agua Abra la llave de...

Страница 37: ...r el pitido y volver a la pantalla de inicio El bot n Salt Level mostrar ADD Agregar parpadeando Despu s de que se agregue sal al gabinete de agua salada recuerde presionar el bot n Salt Level para re...

Страница 38: ...en posici n de servicio consulte Posici n de servicio arriba 2 Aseg rese de que el suministro de agua est abierto 3 Abra la v lvula de entrada y encienda la electricidad hacia el calentador de agua Pa...

Страница 39: ...acia atr s Revise que el artefacto est conectado correctamente Corte de energ a prolongado Restablezca la hora del d a y regenere la unidad Aument la dureza del agua Vuelva a probar el agua y vuelva a...

Страница 40: ...n con el ajuste de sal La cantidad aproximada de agua deber a ser de 5 a 30 cm 2 a 12 Revise si hay conexiones sueltas en la tuber a de agua salada y los conectores Reducci n de presi n intermitente d...

Страница 41: ...iciada por demanda que tambi n cumple con las especificaciones de rendimiento espec ficas dise ado para minimizar la cantidad de agua salada regenerante y de agua que se usa en la operaci n Los abland...

Страница 42: ...al m ximo hacia el drenaje durante la regeneraci n 7 6 L min 2 gpm 7 6 L min 2 gpm Flujo m nimo de agua para contracorriente 7 6 L min 2 gpm 7 6 L min 2 gpm Reducci n del caudal de servicio a 1 0 bar...

Страница 43: ...m tica de 6 9 cm 2 7 pantalla t ctil monocrom tica de 6 9 cm 2 7 Clasificaci n el ctrica 115 V 60 Hz 115 V 60 Hz Conexiones de plomer a NPT 1 NPT macho 1 NPT macho Almacenamiento de sal 90 kg 200 lb 9...

Страница 44: ...r a este producto A O Smith Corporation P O Box 1597 Johnson City TN 37605 1597 877 333 7108 3 10 A OS Lo que A O Smith har Reemplazaremos la pieza defectuosa del producto cubierto o de ser necesario...

Страница 45: ...tema probado y certificado por NSF International conforme a CSA B483 1 y a la norma NSF ANSI 44 para la reducci n de bario radio 226 228 y para la reducci n de la dureza Love it We welcome your rating...

Отзывы: