INSTALLATION GUIDE

2

13

12

Flush Lines

1

 Place water softener in Bypass position. 

Turn on main water supply.

2

 Turn on nearest cold water faucet to flush 

plumbing of any excess soldering flux, 
air, or any other foreign material. Return 
water softener to Service position. 

7

8

9

Check for Leaks

Plug in the Transformer

Turn off all faucets. Check all lines and 
connections for leaks. 

If leaks are found:

 Turn off the main water supply.

 Turn on cold water faucet to depressurize 

the lines.

 Turn off the faucet to eliminate any 

siphoning action.

 Repair all leaks.

 Turn on the water supply.

 Place bypass in Service position to slowly 

fill media tank. (see image)

 Turn on cold water faucet to purge air out 

of media tank.

 Turn off the faucet and recheck for leaks.

Ensure the sensor wire and motor wire 

are connected, then plug the transformer 
power cord to the back of the controller. 
(see Connecting Power)

Plug the transformer into an appropriate 

outlet. Ensure the outlet selected is not 
operated by an On/Off switch.

Program the water softener controller in 

the next step.

Connect Drain Line

Connect Gravity Overflow 
Connection

The overflow line drains away excess water 
should the cabinet overfill or the water 
softener malfunction. (see Gravity Overflow 
Elbow) Ensure the overflow elbow is in the 
down position.

The drain line carries away backwash water 
as part of the regeneration cycle.

Connect drain line to drain end cap (see 

Connect Drain Line) with a minimum 
1/2" (1.27 cm) I.D. tubing (supplied). This 
size cannot be reduced. Note: Using PTFE 
tape or plumber’s putty, screw threaded 
drain fitting into drain end cap.

Route drain line to a floor drain, laundry 

tub, or other suitable waste receptacle. 
Maintain a minimum 2" (5 cm) air gap 
between drain line and flood level rim 
of waste receptacle to prevent back 
siphoning. This drain line should be the 
shortest distance to the suitable drain.

Drain line may be elevated up to 8' 

(2.4 m) from the discharge on the water 
softener if water pressure in your system 
is 40 psi (2.8 bar) or more.

If drain line is 25 feet (7.6 m) or longer, 

increase drain line to 3/4" I.D. The end of 
drain line must be equal to or lower in 
height than the control valve.

5

6

Connect 1/2" (1.27 cm) I.D. tubing (size 
cannot be reduced) between the overflow 
fitting and a floor drain, laundry tub, or 
other suitable waste receptacle. Note: 
This tubing is not supplied with the water 
softener. Ensure the overflow line ends 
at a drain that is at least 3" (8 cm) lower 
than the bottom of the overflow fitting. 
Maintain a minimum 2" (5 cm) air gap 
between the overflow line and the flood 
level rim of the waste receptor to prevent 
back-siphoning. The gravity line cannot be 
run overhead.

Connect Drain Line

NOTICE:

 Keep the drain line from being 

kinked, crimped, or restricted in any way.

NOTICE:

 Drain line may require a hose clamp 

to hold drain line in place. 

Connecting Power

INSTALLATION

NOTICE: 

To prevent untreated water from 

entering your home, avoid using water inside 

your home when water softener is in Bypass 

position. Remember to return to Service 

position when you have finished flushing the 

system or using untreated water.

Gravity Overflow Elbow

Bypass Position

Service Position

Содержание AO-WH-PRO-300

Страница 1: ...OWNER S MANUAL Use this owner s manual to reference installation troubleshooting and replacement information If you need help or have a question we ve got you covered Give us a call at 855 424 9892...

Страница 2: ...Owner s Manual El manual del propietario WHOLE HOUSE SOFTENERS AO WH PRO 300 30 000 Grain Unit Chlorine Reduction AO WH SOFT 450T 45 000 Grain Unit AO WH PRO 500 50 000 Grain Unit...

Страница 3: ...a question we ve got you covered Give us a call at 855 424 9892 Note We recommend using an approved or certified professional to connect into existing plumbing and or if drilling is required Tools re...

Страница 4: ...l comply with all local and state plumbing codes To prevent back siphoning provide an adequate air gap or a siphon break see Installation Steps Power Supply The transformer supplied is for a standard...

Страница 5: ...is recommended Do not use rock salt You may use a salt substitute such as potassium chloride in place of water conditioner salt If potassium chloride is used in place of salt multiply compensated hard...

Страница 6: ...ted water To prevent untreated water from entering the home water should not be used inside the home when the appliance is in Bypass Mode Ensure that the appliance is returned to Service Mode when the...

Страница 7: ...ppliance unless otherwise recommended Water Heaters If less than 10 3 m of pipe connects the water treatment appliance s to the water heater install a check valve between water treatment appliance and...

Страница 8: ...inimum 1 2 1 27 cm I D tubing supplied This size cannot be reduced Note Using PTFE tape or plumber s putty screw threaded drain fitting into drain end cap 2 Route drain line to a floor drain laundry t...

Страница 9: ...model not all options will apply The controller should only display options available to the model for which it is programmed Display Settings Units Toggle between English and Metric units Time Set t...

Страница 10: ...less than 10 VAC replace the transformer Defective circuit board With 12 VAC present at controller replace the controller Problem Possible Cause Solution Appliance Stays In Regeneration Controller not...

Страница 11: ...m has been installed It is typically less than the efficiency due to individual application factors including water hardness water usage and other contaminates that reduce the softeners capacity Reduc...

Страница 12: ...27 5 21 27 5 80 42 5 30 42 5 114 Controller Type 2 8 color touch screen 2 8 color touch screen 2 8 color touch screen Electrical Rating 115V 60 Hz 115V 60 Hz 115V 60 Hz Plumbing Connections NPT 1 mal...

Страница 13: ...Water containing sand bacterial iron algae sulphur tannins organic matter or other unusual substances should be treated to remove these substances before they enter this product What A O Smith will d...

Страница 14: ...o Si necesita ayuda o tiene alguna consulta nosotros nos encargamos Ll manos al 855 424 9892 Nota Recomendamos llamar a un profesional autorizado o certificado para realizar conexiones en tuber as exi...

Страница 15: ...s Para evitar el sifonaje de aguas residuales al agua de suministro proporcione un espacio de aire adecuado o un destructor de acci n sif nica consulte los Pasos de instalaci n Suministro de alimentac...

Страница 16: ...salada El tanque debe tener agua Tambi n puede agregarla directamente al gabinete de agua salada si no hay sal y hay solo agua en el gabinete Inicie una regeneraci n manual Haga lo siguiente Cumpla co...

Страница 17: ...a su hogar no se debe usar el agua dentro del hogar cuando el artefacto est en modo de derivaci n Aseg rese de que el artefacto vuelva al modo de servicio cuando se repare o cuando termine el uso de a...

Страница 18: ...miende lo contrario Cuando instale filtros adicionales como un filtro de carb n para agua de pozo coloque el filtro despu s de cualquier artefacto de acondicionamiento de agua a menos que se recomiend...

Страница 19: ...iona con el ablandador de agua Aseg rese de que la tuber a de rebose termine en un drenaje que est al menos 8 cm 3 m s abajo que la parte inferior del conector de rebose Mantenga un espacio de aire de...

Страница 20: ...rna entre unidades m tricas e imperiales Time Hora Ajusta la hora del d a actual Regen Time Tiempo de regeneraci n Ajusta el tiempo de regeneraci n Ajustes de regeneraci n Type Tipo Alterna entre High...

Страница 21: ...a posible Soluci n El artefacto se mantiene en regeneraci n El controlador no est instalado adecuadamente Aseg rese de que el controlador est completamente instalado en la placa de cubierta Disco magn...

Страница 22: ...L Radium 226 228 5 pCi L 226 228 25 pCi L Modelo Eficacia nominal Dosis de sal Capacidad con esa dosis AO WH SOFT 450T 5 210 grains lb 742 grams kg 1 25 lb 0 57 kg 6 510 grains 422 grams AO WH SOFT P...

Страница 23: ...ientes Tampoco cubre lo siguiente Da os indirectos o consecutivos a causa de una falla del producto Obstrucci n Da o producto de uso de suministros de agua no potable Costos de mano de obra para insta...

Страница 24: ...componentes visite AOSmithAtLowes com o visite su tienda Lowe s local Si necesita ayuda o tiene alguna consulta nosotros nos encargamos Ll manos al 855 424 9892 100238095 System Tested and Certified b...