A.O. Smith ADR75-V-ET-1 Скачать руководство пользователя страница 15

Take the water inlet pipe from the quick joint of membrane housing and unscrew the 
membrane housing with its wrench. Then take RO membrane out of vacuum package and 
install the end with four O rings into membrane housing tightly (see Diagram 8), in the end 
install the housing cover and tighten it with cover wrench. Reconnect the water inlet pipe into 
the quick joint of membrane housing and then lock the membrane housing clip into the large 
single clip.

How to install RO membrane

Warning:

5)

Pay attention to RO membrane direction during installation;
Check whether one end of the membrane has 4 O rings or not when installing RO membrane.

If it is installed properly, RO membrane can be installed into membrane housing easily. if it is 
difficult for membrane to install into it, don’t insert RO membrane into membrane housing 
violently which might cause permanent damage to membrane housing and membrane element 
(The manufacturer is not liable for any damage to membrane caused by improper installation);

Damage to membrane housing and RO membrane caused by above-mentioned reasons is not 
included in the warranty scope.

15

Take out two suitable lengths of 1/4'' water pipe and connect them with the wastewater 

RXWOHWDQGRYHUIORZRXWOHWDWWKHEDFNRIWKHPDFKLQH8VHDijPPGULOOWRSXQFKWZRVPDOOKROHV

into the sink drain pipe.  Place the other ends of the wastewater pipe and overflow pipe just 
inside the holes.  Put some silica gel where the 6mm pipes and the drain pipe connect to prevent 
leakage and use a cable tie to attach the wastewater pipe and overflow pipe to the drain pipe. 

Notice: The highest point of overflow water pipe cannot be higher than overflow 
outlet. Otherwise, water is not able to flow down. 

Notice : Use a bigger container to hold water before installing the 3rd stage 
super dense filter cotton. Install the 3rd stage filter until there is no black water 
coming out. 

How to install waste water pipe and overflow pipe

3)

First, take out water collector and remove two screws. Press 
plastic padlock and dismantle panel of the unit. Unscrew the 
1st, 2nd and 3rd filter cartridges from air purifier interior, and 
install corresponding dense filter cotton and pre-carbon filter. 
When the 2nd activated carbon filter is used for the first time, 

some activated carbon powder from the activated carbon 
filter will flow into the 3rd stage dense cotton filter or even RO 
membrane, resulting in filter and membrane component 
damage. So before installing dense filter cotton, place a 
bigger container in the installation place of the 3rd stage filter 

cartridge, then turn on inlet valve and switch, power on and 
flush pre-activated carbon. When there is no black water 
coming out, turn off power switch and install dense filter 
cotton into the 3rd stage filter cartridge. (see Diagram 7)

How to install filter

4)

Diagram

 7

Содержание ADR75-V-ET-1

Страница 1: ...MODEL ADR75 V ET 1...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...OZN INORJ RUIQ L TIZOUT ZU VXK KTZ INORJXKT LXUS 4 1 1 Pure water Waste water Child Lock Max 92 Min 9...

Страница 5: ...OTM RKIZXOIGR OXI OZ OGMXGS GZKX RU OGMXGS 6XUJ IZ TZXUJ IZOUT U ZU TYZGRR JP YZSKTZ 6XUIKJ XKY 5VKXGZOTM TYZX IZOUTY 6XK TYZGRRGZOUT 6XKVGXGZOUT TYZX IZOUT LUX 6XUVKX TYZGRRGZOUT 3GOTZKTGTIK VQKKV OR...

Страница 6: ...esult if the power source and machine s current are incompatible Electrical shock a short circuit fire or damage to the machine s housing may occur as a result Don t make the machine wet Don t damage...

Страница 7: ...r fire may occur as a result of hindering heat dissipation Corrosive material might corrode inner components Or if some toxic substances penetrate into water purifier pipeline pollution water leakage...

Страница 8: ...e may result When ambient temperature is below 5 make sure anti freezing measures such as turning on the heat or air conditioner should be adopted Otherwise water freezes in the machine due to low tem...

Страница 9: ...Normal temperature AC 220V 50Hz 500W 85W 630W 0 1MPa 0 35MPa a 330 3 Accord with requirements of Sanitary Standard for Hygienic Safety and Function Evaluation on Treatment Devices of Drinking Water r...

Страница 10: ...use Power plug L incoming line Power adaptor Switching power supply Refrigerating test Main control panel Power panel M 3 Structural Drawing 4 Electrical Circuit Diagram 10 LED screen Hot water switch...

Страница 11: ...n for 3 seconds to switch between locked and unlocked The default status is unlocked Note Pressing hot water button room temperature button can get corresponding water can only choose one type Push it...

Страница 12: ...heating heating standby icon turns off when heating system is closed 6 refrigerating refrigerating refrigerating standby icon turns off when refrigerating system is closed 7 child lock icon stays on w...

Страница 13: ...2 seconds as a cycle 4 super high temperature alarm F5 appears on Alarm buzzes 5 times with 2 seconds as a cycle 5 Ultra low temperature alarm F6 appears on Alarm buzzes 6 times with 2 seconds as a cy...

Страница 14: ...int refer to Diagram 6 and screw the metal nut to right position connect the other end of water pipe with the inlet interface on the back of the machine Please be noted that the water pipe shall be pl...

Страница 15: ...e sink drain pipe Place the other ends of the wastewater pipe and overflow pipe just inside the holes Put some silica gel where the 6mm pipes and the drain pipe connect to prevent leakage and use a ca...

Страница 16: ...for the first time after finishing the installation of filter and RO membrane cut off a certain length of 1 4 water pipe and connect it into outlet end of post activated carbon Then turn on inlet valv...

Страница 17: ...se the machine again turn on inlet valve and inlet switch After make sure that there is no water leakage turn on power switch When the unit stops producing water switch hot water on The Operating in t...

Страница 18: ...ivated carbon Firstly turnoff water inlet valve and unscrew corresponding filter cartridge with filter cartridge wrench Take out old filter and place new filters into the filter cartridges note dense...

Страница 19: ...than 75GPD The rated gross pure water output is 1000L Tested according to requirements of Sanitary Standard for Hygienic Safety and Function Evaluation on Treatment Devices of Drinking Water Reverse...

Страница 20: ...noid valve fails Can not Decompression of check valve Heating system is not powered on Heating rod failure Replace hot tank No water or low level water in pure water tank Observe waste water Replace i...

Страница 21: ...1 piece User manual 1 piece Silicone pad and demonstration instruction 1 piece Accessories Including tee joint 2 pipe plug 3 pipe plug 3 nut Hangers for faucet waste water clip Teflon tape M5h16mm big...

Страница 22: ...WarrantyTerms Conditions 22...

Страница 23: ...23 ADR75 V ET 1...

Страница 24: ......

Отзывы: