Main menu
56
Instruction Manual BFC
8
gis
The display now shows the menu for the week program, see
Figure 8.7
. With
the default setting, the program switches on and off every day at 00:00 and
23:59 hours respectively, the water temperature is 65ºc and the pump is
switched on (
P
).
Example
As an example, we will set the switch-on time for Sunday to 08:15 hours, and
the matching switch-off time to 12:45 hours. The water temperature will be set
to 75ºC and the pump will run continuously.
The following settings are entered one by one via the menu: the switch-on time,
the switch-off time, the desired water temperature, and the state of the program-
controlled pump.
Setting the switch-on time
2. Bring the cursor to
SU
and press
E
. The sub-menu shown in
Figure 8.8
will appear. The day indicated by the
»
will blink.
3. Use
H
and
L
to select the day desired. In the example, this is
SU
(Sunday).
Confirm with
E
.
The cursor moves to the hour digits, which will blink. See
Figure 8.9
.
4. Use
H
and
L
to select the hour. In the example this is
08
.
Confirm with
E
.
The cursor moves to the minute digits, which will blink. See
Figure 8.10
.
n
Remark
Because the switch-off time can never be earlier than the switch-on time, the
switch-off time setting is automatically adjusted with the switch-on time.
5. Use
H
and
L
to select the minutes. In the example this is
15
.
Confirm with
E
.
The cursor moves to the switch-off hour digits, which will blink. See
Figure 8.11
.
Setting switch-off time
6. Use
H
and
L
to select the hour. In the example this is
12
.
Confirm with
E
.
DAY TIME Tset
ON »SU 00:00 65ÉC P
OFF SU 23:59
ON MO 00:00 65ÉC P
OFF MO 23:59
ON TU 00:00 65ÉC P
OFF TU 23:59
ON WE 00:00 65ÉC P
OFF WE 23:59
ON TH 00:00 65ÉC P
OFF TH 23:59
ON FR 00:00 65ÉC P
OFF FR 23:59
ON SA 00:00 65ÉC P
OFF SA 23:59
INSERT
DELETE
START OPERATION
Figure 8.7
Standard week
program
ON »SU 00:00
OFF SU 23:59
Tset 65ÉC
PUMP ON
SAVE
Figure 8.8
Week programme
ON SU»08:00
OFF SU 08:00
Tset 65ÉC
PUMP ON
SAVE
Figure 8.9
Setting switch-on
hours in week program
ON SU 08»15
OFF SU 08:15
Tset 65ÉC
PUMP ON
SAVE
Figure 8.10
Setting switch-on
minutes in week program
ON SU 08:15
OFF SU»08:15
Tset 65ÉC
PUMP ON
SAVE
Figure 8.11
Setting switch-off
hours in week program
Содержание 28 30 50 60
Страница 2: ...your installer www aosmithinternational com...
Страница 4: ...4 Instruction Manual BFC...
Страница 12: ...Introduction 12 Instruction Manual BFC 1 gis...
Страница 38: ...Installation 38 Instruction Manual BFC 3 is...
Страница 42: ...Filling and draining 42 Instruction Manual BFC 4 gis...
Страница 48: ...Status of the appliance 48 Instruction Manual BFC 6 gis...
Страница 64: ...Main menu 64 Instruction Manual BFC 8 gis...
Страница 68: ...Service program 68 Instruction Manual BFC 9 is...
Страница 84: ...Maintenance frequency 84 Instruction Manual BFC 11 gs...
Страница 94: ...Release R 1 3 UK 94...