12-5. AFR rod function
ф&ƵŶĐƟŽŶх
dŚĞ&ZƌŽĚĐŚĞĐŬƐŇĂŵĞĐŽŶĚŝƟŽŶƐĚƵƌŝŶŐĐŽŵďƵƐƟŽŶ͘tŚĞŶƚŚĞ&ZƌŽĚĚĞƚĞĐƚƐƵŶĞdžƉĞĐƚĞĚŇĂŵĞ
ĐŽŶĚŝƟŽŶƐ͕ƚŚĞĐŽŵƉƵƚĞƌďŽĂƌĚŽĨƚŚĞǁĂƚĞƌŚĞĂƚĞƌĂĚũƵƐƚƐƚŚĞĨĂŶŵŽƚŽƌƐƉĞĞĚƚŽĞŶƐƵƌĞƚŚĂƚĂŝƌĂŶĚ
ĨƵĞůĂƌĞĂůǁĂLJƐĂƚĂƉƌŽƉĞƌŵŝdžƚƵƌĞƌĂƟŽ͕ŵŝŶŝŵŝnjŝŶŐĞŵŝƐƐŝŽŶƐ͘
фdŚĞƌĞůĂƟŽŶƐŚŝƉďĞƚǁĞĞŶƚŚĞ&ZƐƚĂŐĞĂŶĚƚŚĞ͞ϭϬϭ͟ĂŶĚ͞ϵϵϭ͟ĞƌƌŽƌĐŽĚĞƐх
;ŽŶĚŝƚŝŽŶŽĨ&ZƐƚĂŐĞͿ
പͻപϬƚŽϱ͗ŝƌͲƌŝĐŚ
പͻപ/ŶŽƌĚĞƌƚŽƐŽůǀĞƚŚĞ͞ĂŝƌĞdžĐĞƐƐ͟ƉƌŽďůĞŵ͕ƚŚĞ
ĨĂŶŵŽƚŽƌƐƉĞĞĚŝƐĂƵƚŽŵĂƚŝĐĂůůLJĚĞĐƌĞĂƐĞĚ
and AFR combustion stage goes down.
പͻപϲ͗ĞĨĂƵůƚ
പͻപϳƚŽϭϲ͗'ĂƐͲƌŝĐŚŽƌŝƌƐŚŽƌƚĂŐĞ
പͻപ/ŶŽƌĚĞƌƚŽƐŽůǀĞƚŚĞ͞ĂŝƌĚĞĨŝĐŝĞŶĐLJ͟
ƉƌŽďůĞŵ͕ƚŚĞĨĂŶŵŽƚŽƌƐƉĞĞĚŝƐ
automatically increased and AFR
combustion stage goes up.
പͻപϭϱ͗͞ϭϬϭ͟ĞƌƌŽƌĐŽĚĞ
പͻപϭϲ͗͞ϵϵϭ͟ĞƌƌŽƌĐŽĚĞ
പͻപtŚĞŶƚŚĞ͞ϭϬϭ͟Žƌ͞ϵϵϭ͟ĞƌƌŽƌĐŽĚĞĂƉƉĞĂƌƐ͕
see section 12-4.
16
15
6
0
ĞĨĂƵůƚĐŽŶĚŝƚŝŽŶ
"101" error code
"991" error code
Stage
FM
нϭϱй
нϭϯ͘ϱй
Ϭй
Ͳϵй
...........................
..........................
................
................
ф&ZŶŽƌŵĂůƌĂŶŐĞŽĨǀĂůƵĞƐх
ͻ
/ĨƚŚĞĚĞƚĞĐƚĞĚ&ZǀĂůƵĞŝƐŚŝŐŚĞƌƚŚĂŶƚŚĞŶŽƌŵĂůǀĂůƵĞ͕ƚŚĞ&DƐƉĞĞĚŝƐŝŶĐƌĞĂƐĞĚ͘
ͻ
/ĨƚŚĞ&ZǀĂůƵĞŝƐůŽǁĞƌƚŚĂŶƚŚĞŶŽƌŵĂůǀĂůƵĞ͕ƚŚĞ&DƐƉĞĞĚŝƐĚĞĐƌĞĂƐĞĚ͘
ͻ
These values are read with the front cover close
.
ͻ
DĞĂƐƵƌĞƚŚĞǀĂůƵĞƐĂŌĞƌƚŚĞǁĂƚĞƌŚĞĂƚĞƌĨŽƌƚĞŶŵŝŶƵƚĞƐ͘
ΎdŚĞ&ZƐƚĂŐĞĐĂŶďĞĐŽŶĮƌŵĞĚŝŶ͞ŝĂŐŶŽƐƟĐDŽĚĞ͘͟;^ĞĐƟŽŶϭϮͲϭͿ
240 (T-H3J) models
Installation type
Direct vent
Outdoor
Gas type
Propane
Natural gas
Propane
Natural gas
Combustion
mode
Dy
12.0 to 35.0
23.6 to 58.0
6.0 to 41.0
17.1 to 55.0
D/E
5.0 to 20.0
3.5 to 11.0
3.0 to 15.0
3.8 to 19.0
340 (T-H3J) models
Installation type
Direct vent
Outdoor
Gas type
Propane
Natural gas
Propane
Natural gas
Combustion
mode
Dy
19.0 to 52.0
24.6 to 65.0
7.0 to 47.0
21.4 to 56.0
D/E
5.0 to 20.0
3.5 to 11.0
3.0 to 15.0
3.8 to 19.0
540 (T-H3) models
Installation type
Direct vent
Outdoor
Gas type
Propane
Natural gas
Propane
Natural gas
Combustion
mode
Dy
20.0 to 57.0
26.2 to 78.0
7.0 to 48.0
22.3 to 60.0
D/E
5.0 to 20.0
3.5 to 11.0
3.0 to 15.0
3.8 to 19.0