TR
OUBLE
SHOO
TING
Electric Tankless Water Heater •
17
Error Codes for Point-of-Use Models
If you have a two- or four-chamber model, see page 19.
WARNING
Electric Shock Risk
Contact with the electrical parts inside the water heater can result in severe injury or death from electrical shock:
•
Disconnect power by opening the circuit breaker(s) or removing the fuses before installing or servicing.
•
Some models are connected to more than one branch circuit, and more than one disconnect switch may be
required to de-energize the equipment. All branch circuits must be disconnected prior to service.
The LED on the circuit board will display a series of
RED
fl
ashes, and each series of
fl
ashes represents one digit in the code. A er
each sequence, the LED will
fl
ash
GREEN
. See the examples below. (Components are iden
fi
ed in Figure 8, page 18.)
NOTICE:
•
There may be mul ple codes; verify all sequences.
•
If you want to
hear
the
fl
ash code, press the mode bu on for two seconds. This will turn the audible beeper on. See Figure 8,
page 18.
Examples from the Table Below:
Flash Code Sequence:
12/14
(Temperature Sensor Failure). The 12/14 code would be displayed like this:
1
2
/
1
4
1 red
fl
ash—pause—2 red
fl
ashes—pause—green
fl
ash—one red
fl
ash—pause—four red
fl
ashes—pause—green
fl
ash
Flash Code Sequence:
22
(Temperature Sensor Failure). The 22 code would be displayed like this:
2
2
2 red
fl
ashes—pause—two red
fl
ashes—pause—green
fl
ash
A er you iden fy the code, locate its descrip on and solu on in the table.
Flash Code
Sequence
Description
Action / Solution
12/14
22
13/16
Temperature sensor failure
Turn o
ff
all power to the water heater.
Open a nearby hot water
fi
xture
and allow water to run through the heater for about 5 minutes. Check
the resistance of all temperature sensors (thermistors), then compare the
readings. The failed sensor will be the one that has a resistance reading
(ohms) that is at least 10% to 15% di
ff
erent from all of the others.
14/16
Temperature sensor shorted
Check wiring. Replace as necessary.
12/13
Temperature sensor open
Check wiring. Replace as necessary.
11
Disable switch open
Install the missing jumper(s) on the circuit board as shown in Figure 8,
page 18. Both jumpers must be in place.
17
High temperature shutdown
(
This code will clear when the
condi
Ɵ
on is corrected.)
This code is triggered when the temperature of the water has exceeded
the set point by more than 8°F.
1.
Turn o
ff
all power to the water heater.
Open a nearby hot water
fi
xture and allow water to run through the
heater for about 5 minutes. Check the resistance of the temperature
sensors (thermistors). If one of the thermistors has a resistance that
is much higher than the others, replace that thermistor.
2.
If the issue
persists, the circuit board (control board) may need to be replaced.
Contact Technical Support.
TROUBLESHOOTING