vent pIpe preparatIon

1.  INITIAL PREPARATION.

  A.) Make  sure  the  solvent  cement  you  are  planning  to  use

 

 

is designed for the specific application you are attempting.

 

B.) Know the physical and chemical characteristics and limitations of the

 

 

PVC and CPVC piping materials that you are about to use.

 

C.) Know the reputation of your manufacturer and their products.

 

D.) Know your own qualifications or those of your contractor. The solvent

 

 

welding technique of joining PVC and CPVC pipe is a specialized skill

 

 

just as any other pipe fitting technique.

 

E.) Closely supervise the installation and inspect the finished job before

 

 

start-up.

 

F.)  Contact the manufacturer, supplier, or competent consulting

 

 

agency  if  you  have  any  questions  about  the  application  or

 

 

installation of PVC and CPVC pipe.

  G.)  Take the time and effort to do a professional job. Shortcuts will only

 

 

cause you problems and delays in start-up. By far, the majority of

 

 

failures in PVC and CPVC systems are the result of shortcuts and/or

 

 

improper joining techniques.

2.  SELECTION OF MATERIALS.

 

  Cutting Device - Saw or Pipe Cutter.

 

 

  Deburring Tool, Knife, File, or Beveling Machine (2” and above).

 

  Brush - Pure Bristle.

 

  Rag - Cotton (Not Synthetic).

 

  Primer and Cleaner.

 

  Solvent Cement - PVC for PVC Components and CPVC for CPVC

 

 

Components.

 

  Containers - Metal or Glass to hold Primer and Cement. Select the

 

 

type of PVC or CPVC materials to be used on the basis of their

 

 

application  with  respect  to  chemical  resistance,  pressure  rating,

 

 

temperature characteristics, etc.

 

  Insertion Tool - Helpful for larger diameter pipe and fittings 6 inches

 

 

(15.2cm) and above.

prIMer

It is recommended that Tetrahydrofuran (THF) be used to prepare the 

surfaces of pipe and fittings for solvent welding. Do not use water, 

rags, gasoline or any other substitutes for cleaning PVC or CPVC 

surfaces. A chemical cleaner such as MEK may be used.

ceMent

The  cement  should  be  a  bodied  cement  of  approximately  500  to 

1600 centipoise viscosity containing 10-20% (by weight) virgin PVC 

material  solvated  with  tetrahydrofuran  (THF).  Small  quantities  of 

dimethyl  formamide  (DMF)  may  be  included  to  act  as  a  retarding 

agent to extend curing time.  Select the proper cement; Schedule 40 

cement should be used for Schedule 40 pipe. Never use all-purpose 

cements, commercial glues and adhesives or ABS cement to join PVC 

or CPVC pipe and fittings.

applIcators

Select a suitable pure bristle type paint brush. Use a proper width brush 

or roller to apply the primer and cement (see chart below). Speedy 

application of cement is important due to its fast drying characteristics.  

IMPORTANT NOTE: A dauber type applicator should only be used 

on pipe sizes 2” and below. For larger diameter pipe, a brush or roller 

must be used.

RECOMMENDED BRUSH* SIZE FOR PRIMER

and ceMent applIcatIons

Nominal Pipe (IPS)

Size Brush Width

2

1.5” (3.8cm)

3

1.5”-2.5” (3.8cm - 6.4cm)

*use onlY natural BrIstle

3.  MAKING THE JOINT.

  A.) Cutting  Pipe  must  be  squarely  cut  to  allow  for  the  proper

 

 

interfacing of the pipe end and the fitting socket bottom. This

 

 

can be accomplished with a miter box saw or wheel type cutter

 

 

Wheel type cutters are not generally recommended for larger

 

 

diameters since they tend to flare the corner of the pipe end. If

 

 

this  type  of  cutter  is  used,  the  flare  on  the  end  must  be

 

 

completely removed.

NOTE: Power saws should be specifically designed to cut plastic pipe.

step a

Содержание 197835-001

Страница 1: ... VENT GAS MODELS WITH HOT SURFACE IGNITION ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOU ARE UNSUCCESSFUL CALL THE TECHNICAL SUPPORT PHONE NUMBER SHOWN ON THE WATER HEATER LABELING RESIDENTIAL GAS WATER HEATERS For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER Ashland City TN 37015 www hotwater com...

Страница 2: ...other reproductive harm This appliance can cause low level exposure to some of the substances listed IMPORTANT DEFINITIONS Qualified Installer or Service Agency Installation and service of this water heater requires ability equivalent to that of a Qualified Agency as defined by ANSI below in the field involved Installation skills such as plumbing air supply venting gas supply electrical supply are...

Страница 3: ...3 GENERAL SAFETY ...

Страница 4: ...4 GENERAL SAFETY ...

Страница 5: ...Carefully plan the place where you are going to put the water heater Correct combustion vent action and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires see Figures 1 and 2 Examine the location to ensure the water heater complies with the Facts to Consider About Location section in this manual 6 For California installation this water h...

Страница 6: ...rface Igniter I Junction Box J Gas Control Valve Thermostat K Display Board L Top Plastic Enclosure Y Inlet Dip Tube Z T P Relief Valve AA Rating Plate BB Labels CC Drain Valve DD Vent Terminal EE Metal Drain Pan FF Anode GG Insulation HH Upper Temperature Probe II Access Door REPLACEMENT PARTS AND DELIMING PRODUCTS Replacement parts and recommended delimer may be ordered through authorized servic...

Страница 7: ...Supply Pressure for Natural Gas 3 50 87kPa Minimum Supply Pressure for Propane Gas 8 00 1 99kPa Minimum pressure must be maintained under both load and no load dynamic and static conditions Recovery Capacities U S Gallons Hr and Liters Hr at Temperature Rise Indicated Model Input Recovery Capacities Rating Btu hr Rating kW Temp Rise F 30 40 50 60 70 80 90 100 110 120 130 140 C 17 22 28 33 39 44 50...

Страница 8: ...ntally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and sig...

Страница 9: ...cal code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a Mixing Valve should be used at the hot water taps used by these people or at the water heater see Figure 2 Mixing valves are available at plumbing supply or hardware...

Страница 10: ... water heater is installed Water heaters are sometimes installed in locations where leakage may result in property damage even with the use of a drain pan piped to a drain However unanticipated damage can be reduced or prevented by a leak detector or water shut off device used in conjunction with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and ...

Страница 11: ...on blanket frequently to make certain it does not sag thereby obstructing combustion air flow COMBUSTION AIR AND VENTILATION Agas water heater cannot operate properly without the correct amount of air for combustion Do not install in a confined area such as a closet unless you provide air as shown in the Facts to Consider About Location section Never obstruct the flow of ventilation air If you hav...

Страница 12: ...irectly communicating with the outdoors each opening should have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 7 FIGURE 7 2 When communicating with the outdoors through vertical ducts each opening should have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all...

Страница 13: ...contact with the heater should not contain any of these chemicals If necessary uncontaminated air should be obtained from remote or outside sources The limited warranty is voided when failure of water heater is due to a corrosive atmosphere See limited warranty for complete terms and conditions Water Piping HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a te...

Страница 14: ...0 psi 1 035 kPa and a discharge capacity not less than the water heater Btu hr input rate as shown on the water heater s model rating plate For safe operation of the water heater the relief valve must not be removed from its designated opening nor plugged The temperature pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve Position the...

Страница 15: ...s supply line serving the water heater and A drip leg sediment trap ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit Be sure to check all the gas piping for leaks before lighting the water heater Use a soapy water...

Страница 16: ...ower front of the water heater 2 Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use 3 To insure complete filling of the tank allow air to exit by opening the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping 4 Check all water pipi...

Страница 17: ...Y BE EXTREMELY HOT DURING OPERATION WARNING VENT HOOD S MAY BE EXTREMELY HOT DURING OPERATION FIGURE 15A CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY COLD AREAS THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED ...

Страница 18: ...AY BE EXTREMELY HOT DURING OPERATION WARNING VENT HOOD S MAY BE EXTREMELY HOT DURING OPERATION FIGURE 15C CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY COLD AREAS THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED ...

Страница 19: ...ystem components be certified to ULC S636 This water heater has been design certified to be vented with PVC pipe certified and marked as complying with ULC S636 This water heater is supplied with a 2 inch 22 5 degree termination elbow that is a special fitting that must be used with the appliance Any outlet piping fittings and glue used to vent this appliance that is not supplied by the manufactur...

Страница 20: ...ll Place some of the caulking on the back of the plate to hold it against the wall after installation If the vent pipe is installed up to the wall with a coupling on the end against the wall opening the pipe with the vent terminal can be prepared for gluing before inserting through the wall Slide the pipe through the wall and insert into the coupling on the other side of the wall making sure that ...

Страница 21: ...this step on the inside wall if necessary 2 Cut a length of 3 PVC pipe about 3 5 8 9 cm longer than the wall thickness at the opening 3 Glue the intake vent terminal to the section of the pipe 4 Slide the wall plate over pipe to stop against intake vent terminal 5 Place a bead of caulking not supplied around the gap between the pipe and the wall Place some of the caulking on the back of the plate ...

Страница 22: ...of The total vent system should not exceed the equivalent feet of pipe as listed in Table 1 Provide support for all pipe protruding through the roof All piping should be properly secured The vent system piping should be supported every 5 feet 1 5 m of vertical run and every 3 feet 91 cm of horizontal run All piping and fittings must be joined by the proper procedures as described under VENT PIPE P...

Страница 23: ...chances to intake contaminants and less visible vent vapors 2 Cut 1 hole 5 in diameter 3 Partially assemble concentric vent termination kit a Cement Y concentric fitting to larger diameter kit pipe see Figure A b Cement rain cap to smaller diameter kit pipe see Figure A Figure d NOTE Instead of cementing the smaller pipe to the rain cap a field supplied stainless steel screw may be used to secure ...

Страница 24: ... kit a Cement the Y concentric fitting to larger diameter kit pipe see Figure A b Cement the rain cap to the smaller diameter kit pipe see Figure A NOTE Instead of cementing the smaller pipe to the rain cap a field supplied stainless steel screw may be used to secure the 2 components together when field disassembly is desired for cleaning see Figure D WARNING When using alternate screw assembly me...

Страница 25: ...ted vented with concentric vent terminations near each other each appliance must be individually vented NEVER common vent this appliance When two or more appliances are direct vented using concentric vent terminations the appliances may be vented as shown in Figure H and Figure I Figure H Concentric Vent Terminations for Horizontal Direct Venting Figure I Concentric Vent Terminations for Vertical ...

Страница 26: ...MER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleaning PVC or CPVC surfaces A chemical cleaner such as MEK may be used CEMENT The cement should be a bodied cement of approximately 500 to 1600 centipoise viscosity containing 10 20 by weight virgin PVC material solvat...

Страница 27: ... distance and make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristle brush This process softens and prepares the PVC or CPVC for the solvent cementing step Move quickly and without hesitation to the cementing procedure while the surfaces are still wet with primer E Application of solvent ...

Страница 28: ...erminal Also verify that the vent length does not exceed the maximum allowed as shown in the Vent Section of this manual BLOCKED INTAKE SWITCH SEE FIGURE 12 The Blocked Intake Switch is set up to shut the unit off when a build up of negative pressure in the intake air pipe occurs This switch is a negative pressure switch that requires an increase in negative pressure to change the electrical conta...

Страница 29: ...RRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING POWER VENT WIRING SCHEMATIC FIGURE 24 THIS WATER HEATER IS POLARITY SENSITVE BEFORE APPLYING ELECTRICITY TO THIS HEATER BE CERTAIN THAT SUPPLY NEUTRAL WIRE TO GROUND CHECK INDICATES ZERO VOLTAGE ...

Страница 30: ...ooded water heater Do not attempt to repair the unit It must be replaced OPERATING INSTRUCTIONS 1 Set the thermostat to the lowest setting 2 Set the ON OFF switch on the control panel to the OFF position 3 Turn off all electrical power to the appliance if service is to be performed BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES 1 STOP Read the safety informa...

Страница 31: ...h limit switch operation occurs TEMPERATURE REGULATION Time to Produce 2nd 3rd Degree Temperature Setting Burns on Adult Skin It is recommended that lower water temperatures be used to avoid the risk of scalding It is further recommended in all cases that the water temperatures be set for the lowest temperature which satisfies your hot water needs This will also provide the most energy efficient o...

Страница 32: ...ter is operating the user interface will display the desktop screen if there are no active faults or warnings An example of this screen is shown to the right The temperature on this screen is the Operating Set Point The Operating Set Point is the temperature at which the water heater will maintain the water inside the tank The second line on the screen is a text description of the Operational Stat...

Страница 33: ...ferent temperature readings in the tank along with adjusting the Operating Set Point ACTION From the desktop screen press Menu DISPLAY 2 Operating States In the main desktop screen there are some specific Operating States that are indicated on the status line These are summarized below ACTION From the Main Menu press Select to enter the Temperatures screen DISPLAY ACTION Press Change then use the ...

Страница 34: ...and determine the appropriate action Part of this is displaying the information on the LCD in plain text that accurately describes the condition and diagnostics information that can be used to correct the issue Faults This is a safety related condition that has been detected by the heater NOTE When these conditions occur the water heater will not continue any further heating cycles and the water w...

Страница 35: ...ed at any time ACTION Press the DOWN button for more information DISPLAY ACTION Press the DOWN key to scroll through the fault history If you select a specific fault you may press the VIEW button to view details regarding this fault DISPLAY 7 Viewing Information About the Heater The electronic control for this water heater monitors many different aspects of the water to ensure safe and optimal ope...

Страница 36: ...in this section OPERATIONAL CONDITIONS SMELLY WATER In each water heater there is installed at least one anode rod see parts section for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell in the hot water The smell is a result of four factors which must a...

Страница 37: ...age to a water heater may not be readily visible or immediately detectable However over a period of time a flooded PERIODIC MAINTENANCE water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact a qualified installer or service agency to replace a flooded water heater Do not attempt to repair the unit It must be replaced At least once a yea...

Страница 38: ...ge line and 2 that the water discharge will not cause any property damage as the water may be extremely hot see Figure 28 If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one If the temperature pres...

Страница 39: ...loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seepage should also be checked To check where threaded portion enters tank insert cotton swab between jacket opening and fitting If cotton is wet follow Draining instructions in t...

Страница 40: ...age CONDENSATION Water on the floor under heater See CONDENSATION section WATER LEAKS Improperly sealed hot or cold supply connections relief valve drain valve or thermostat threads Check for leaks See Figure 1 Leakage from other appliances or water lines Inspect other appliances near water heater Condensation of flue products Refer to CONDENSATION section LEAKING T P Thermal expansion in closed w...

Страница 41: ...41 NOTES ...

Страница 42: ...42 NOTES ...

Страница 43: ...on of it in a modified form or any attempt to repair tank leaks or parts will void this warranty SERVICE AND LABOR RESPONSIBILITY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLY A REPLACEMENT WATER HEATER OR PART THEREOF THE OWNER IS RESPONSIBLE FOR ALL OTHER COSTS Such costs may include but are not limited to a Labor charges for service removal or reinstallation of the water heater or...

Страница 44: ...44 500 Tennessee Waltz Parkway Ashland City TN 37015 Phone 800 527 1953 Fax 800 433 2515 www hotwater com ...

Отзывы: