BTR TANK TYPE HEATERS
SERVICE HANDBOOK
A.O. Smith Water Products
Service Handbook
Irving, Texas ©2000
Training Department
34
STEP 13
PILOT SPARK TEST
STEP 13. PILOT SPARK TEST.
Visually check for spark at the pilot assembly.
Note: The pilot burner mounts on the left side of the main burner.
IF
THEN
The igniter is not sparking:
Check for:
•
A 7/64” spark gap
•
Spark cable continuity
•
Ground cable continuity
Sparking is present:
•
Go to step 14.
Power To Module May Be Interrupted To Reset .
Trial for Ignition
90 sec.
5 min.
90 sec.
5 min.
90 sec.
Call for
heat
Sparking
No
Sparking
Sparking
No
Sparking
Sparking
Continuous
Trial
Sequence
Содержание 120 trough 500