The  MS-1215-S6MS  offers  network-grade  surge  and  noise 

suppression  in  a  versatile  all-metal  cabinet  with  fixed  mounting 

flanges for rack mount installation. Uses only (1) rack space (1U) 

when installed in any 19 inch EIA standard rack. Features network 

grade AC surge suppression with EMI/RFI noise filtering. Includes 

(12)  outlets  (2  front/10  rear),  15ft  AC  power  cord  and  lighted 

Combo Switch / Circuit Breaker. The MS-1215-S6MS is ready for 

use out of the box and requires no configuration.

SUPPRESSION: AC: 120V RMS Clamping / 1800 joules / 60,000 

amps.

FEATURES 

LED STATUS INDICATORS 

This power strip gives a 
constant display of the 

three most critical points 

on a surge protector.

•  The 

RED

 “Surge”

 LED is constantly illuminated letting you 

know the power strip is busy protecting your electronics.
•  The 

GREEN 

“Ground”

 LED lets you know you have a good 

connection to ground. This is important as ground is needed to 

dissipate large power surges.
•  The 

YELLOW “Power” 

LED means the power strip has 

power.

•  ”SURGE”

  LED  indicator  will  turn  off  when  the  surge 

suppression circuit is compromised.

SPECIFICATIONS

•  Overall Length:

 19 inch

•  Number of Receptacles: 

12 (2 front, 10 rear)

•  Cord Length:

 15ft

•  Mounting Type:

 Flange (rack mounting screws not provided)

•  Approval:

 UL Approved

•  Maximum Rating:

 60Hz, 15A, 120V

•  Unit Color:

 Black

•  Housing: 

Steel

•  Dimensions (LxWxD):

 17.25 x 3.25 x 1.75 in

•  Type of Receptacle:

 5-15R (15A 125V) Black Outlet

•  Circuit Breaker:

 15 amp

•  Cord Type: 

14/3 SJT

•  Type of Plug:

 NEMA 5-15P (15A 125V) Molded on Plug

•  Color of Cord:

 Black

•  Cord Location:

 Exits the rear of the housing

•  Switch:

 Lighted

•  Weight:

 5.1 lb (Unit only) / 5.5 lb (Net)

As product improvement is continuous, specifications subject to 
change and without notice.

1

SAFETY PRECAUTIONS 

Please read all instructions before attempting to unpack, install or 

operate this equipment and before connecting the power supply. 

Please keep the following in mind as you unpack and install this 

equipment:
•   Always follow basic safety precautions to reduce the risk of fire, 

electrical shock and injury to persons.

•  To prevent fire or shock hazard, do not expose the unit to rain, 

moisture or install this product near water.
•   Never spill liquid of any kind on or into this product.
•   Never push an object of any kind into this product through any 

openings or empty slots in the unit, as you may damage parts 

inside the unit.
•  Do not attach the power supply cabling to building surfaces.

•  Use only the supplied power supply unit (PSU). Do not use the 

PSU if it is damaged.
•  Do not allow anything to rest on the power cabling or allow any 

weight to be placed upon it or any person walk on it.
•  To protect the unit from overheating, do not block any vents or 

openings in the unit housing that provide ventilation and allow for 

sufficient space for air to circulate around the unit. 

DISCLAIMERS

The information in this manual has been carefully checked and 

is believed to be accurate. We assume no responsibility for any 

infringements of patents or other rights of third parties which 

may result from its use.

We assume no responsibility for any inaccuracies that may be 

contained in this document. We make no commitment to update 

or to keep current the information contained in this document.

We reserve the right to make improvements to this document 

and/or product at any time and without notice.

COPYRIGHT

 

NOTICE

No part of this document may be reproduced, transmitted, 

transcribed, stored in a retrieval system, or any of its part translated 

into any language or computer file, in any form or by any means 

— electronic, mechanical, magnetic, optical, chemical, manual, 

or otherwise — without express written permission and consent.
© Copyright 2020. All Rights Reserved.

Version 1.5 JULY 2020

TRADEMARK

 

ACKNOWLEDGMENTS

All products or service names mentioned in this document may 

be trademarks of the companies with which they are associated.

Содержание MS-1215-S6MS

Страница 1: ...MS 1215 S6MS 12 Outlet Surge Protected Rack Mount Power Strip INSTRUCTION MANUAL 122 Rose Ln Suite 303 Frisco Texas 75036 Email sales a neutronics com A Neutronics com ...

Страница 2: ...ion 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet o...

Страница 3: ...ment and before connecting the power supply Please keep the following in mind as you unpack and install this equipment Always follow basic safety precautions to reduce the risk of fire electrical shock and injury to persons To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water Never spill liquid of any kind on or into this product Never push an ...

Страница 4: ... Inc makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this warranty to such components DESCRIPTIONS A Neutronics Inc warrants for the period and on the terms of the Warranty set forth herein that the A Neutronics Inc product will conform to ...

Отзывы: