![A.MENARINI GlucoMen Day METER 2K Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/a-menarini/glucomen-day-meter-2k/glucomen-day-meter-2k_user-manual_3044979030.webp)
30
Per
for
ma
nce C
ha
ra
ct
er
is
tics
/
English
/ 10
Performance Characteristics
The performance of GlucoMen
®
Day METER 2K Blood Glucose /
β
-Ketone
Monitoring in glucose measurement has been evaluated in laboratory
and in clinical tests following ISO 15197:2013 (EN ISO 15197:2015).
/ 10.1
Glucose: Accuracy
The accuracy of the GlucoMen
®
Day METER 2K system was assessed
by comparing blood glucose results obtained by patients with those
obtained using a YSI Model 2300 Glucose Analyzer, a laboratory
instrument. The following results were obtained by diabetic patients
at clinic centres.
System accuracy results for glucose concentration
< 100 mg/dL
Within ± 5 mg/dL
Within ± 10 mg/dL
Within ± 15 mg/dL
133/168 (79.2 %)
162/168 (96.4 %)
168/168 (100 %)
System accuracy results for glucose concentration
≥ 100 mg/dL
Within ± 5 %
Within ± 10 %
Within ± 15 %
290/432 (67.1 %)
424/432 (98.1 %)
432/432 (100 %)